TOSHIBA Network Camera - IK-WB15A - SDK (Ver 1.00.SC)

17.1Pan/Tilt Operation

wbpantiltapi.cgi

 

17.1.1

Syntax

 

 

 

 

 

 

 

 

1) http://<camip>/api/wbpantiltapi.cgi?cont_2=<value>[&id=<value>]

 

 

 

 

17.1.2

Input

 

 

 

 

 

 

 

 

 

 

Item

 

Type

Entry name

Entry value

Std.val

Unit

 

PT operation

 

-

 

cont_2

1:Pan Left 2:Pan Right 4:Tilt Up 8:Tilt Down

-

-

 

 

 

 

 

 

 

 

16:Center 32:Scan 64:Auto Patrol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

id

any

-

-

 

 

 

 

 

 

 

 

 

 

 

 

17.1.3

Output

 

 

 

 

 

 

 

 

Code

 

Status

 

 

 

 

 

 

20

 

OK

 

 

 

 

 

 

 

32InvalidValue

90CriticalError

17.1.4Example

1)http://10.1.0.1/api/wbpantiltapi.cgi?cont_2=32&id=20050910011600

17.1.5Notes

1)This API requires designated values for “cont_2”.

2)‘id’ is used to prevent the browser from reading the cache. If the cache is not used for the development application, id may have any value.

3)All the parameters are based on “Ceiling Mount”. Therefore, in case of a“Desktop Mount”, set a reversed parameter for right/left and top/bottom sides respectively. Refer to Appendix.C for details.