Installation Checklist

Overview

The following checklist should be completed by the installer. (Note that all pcbs are

 

electronically tested and adjusted before being fitted to the FIP).

 

1.

CABINET & GENERAL

A)Cabinet colour - Standard Cream Wrinkle (BFF 998 CW) - Other: ____________________________________

B)Cabinet undamaged (Paint OK)

C)Door aligned correctly

D)Window undamaged and fitted correctly

F)Cabinet Door locks firmly, operates microswitch (if fitted)

G)Lock - 003 Type & two keys supplied

H)Door seals fitted to top and sides

I)Display Keypad and 4U door fitted & aligned correctly

J)Label LB0602 fitted to l.h.s. of Operator Interface

K)Card bays fitted

L)Operator Manual and battery leads included

M)Panel rating label completed, fitted

N)AS1668 Warning label fitted if Fan Control Modules used

O)Applique label fitted to front.

2.MODULES, CARDS & WIRING

A)SPS fitted securely, pcb & components undamaged

B)LED switch modules fitted correctly, spaced evenly

C)FRCs connecting 64/64 Controller & modules fitted correctly

D)Earth wires fitted to display door, card bays and bay front panels

E)All 4100 style cards fitted to motherboards

F)All 4100 style motherboards connected

G)All 4” x 5” modules fitted securely

H)All cards, modules addressed as per configuration sheet (see note 1 below)

I)The Lithium battery is fitted to the holder on the CPU card

J)Link P3 on the CPU card is fitted to the BAT ON position (see note 2)

K)The CPU card is fitted to its motherboard and the 2 FRCs are connected

I)All fan control zone name labels fitted.

Notes

1.The 64/64 Controller Modules are addressed but the LED/Switch modules are not.

2.The Lithium battery on the CPU Card (Master Controller) that stores time and date is disconnected during shipping by fitting link P3 to the BAT OFF position. It must be reconnected at time of installation.

11-2

Page 146
Image 146
Tyco 4100U installation manual Installation Checklist, Cabinet & General

4100U specifications

The Tyco 4100 series, which includes the 4100U, 4120, and 4020 models, represents a significant evolution in fire alarm and detection systems. These systems are designed to meet the needs of commercial, industrial, and institutional environments, ensuring reliable safety and compliance with the latest regulatory standards.

One of the primary features of the Tyco 4100 series is its modular design. This allows for easy expansion and customization to meet diverse application requirements. The systems support a wide range of detectors, initiating devices, and notification appliances, providing flexibility for different building layouts and fire protection needs.

The 4100U model is particularly noted for its powerful processing capabilities, utilizing advanced digital technology to enhance the speed and accuracy of fire detection. It includes sophisticated algorithms that optimize response times and reduce false alarms, ensuring that the system is both responsive and reliable during emergencies.

The 4120 model is tailored for larger facilities, incorporating advanced networking features that enable communication between multiple control panels. This interconnectedness is crucial for managing complex building systems, allowing for centralized monitoring and control. It integrates with a variety of life-safety systems and can be configured to accommodate a vast number of addressable points, making it ideal for expansive installations.

The 4020 model serves as a cost-effective solution for smaller establishments while maintaining essential functionalities. It focuses on delivering essential fire alarm capabilities without compromising on performance. Despite its more compact design, the 4020 still offers support for numerous devices and can be integrated into larger systems if needed.

All models in the 4100 series leverage modern communication technologies, offering network integration capabilities that enhance their usability. They support various communication protocols, including Ethernet, which facilitates remote monitoring and maintenance options via web-based interfaces. This ensures that system administrators can manage alerts and notifications from anywhere, streamlining incident response.

In summary, the Tyco 4100 series, featuring the 4100U, 4120, and 4020 models, stands out for its adaptability, technological advancements, and versatility. Their robust design caters effectively to diverse environments, making them a preferred choice for fire alarm and safety solutions in various sectors. Companies can rely on these systems not only for compliance but also for enhanced safety and operational efficiency.