Installation

previously (refer to Unlocking Channels on page 49), unlock the next channel and repeat the calibration procedure. Do this for each of the remaining channels.

Select Installation from the Vision 140/150 Main Menu to access these advanced lamp and lens configuration options:

LumaCal™, for maintaining constant lamp brightness

OptiCal™, to save and restore lens positions

Calibration and Test Patterns – LumaCal (Lamp Calibration): LumaCal defines the range of power needed to maintain lamp brightness over time.

For best results, allow the projector to warm up for 15 minutes prior to

Note

using LumaCal.

 

To use LumaCal:

1.Select Installation from the Main Menu.

2.Select Calibration and Test Patterns from the Installation Menu.

3.Select LumaCal from the Calibration and Test Patterns Menu.

4.Select Calibrate LumaCal to calibrate the lamp using your projector's unique specifications (recommended). Or, select Use Default Settings to undo the effects of a previous calibration.

In the event of a power failure, the projector reverts to the default LumaCal settings in which case you should re-calibrate the lamp.

LumaCal lamp calibration takes approximately two minutes.

Note

Installation Menu

 

Installation

 

1.

Language

English

2.

Picture Orientation

Front

3.Reserved

4.Auto Power Up

5.Set Date and Time

6.OSD Adjust

7.IR and Serial Adjust

8.Geometry and Color

9.Calibration and Test Patterns

0.Service Mode Option 1 Card: Empty Option 2 Card: Empty

Calibration and Test Patterns

1.

Test Patterns

Grid

2.

Test Pattern Level

512

3.Freeze Image

4.

Color Enable

White

5.Odd Pixel Adjustment

6.Reserved

7.Clipping Detector

8.Level Detector

9.

Level Value

512

0.Aspect Ratio Overlay

LumaCal Calibrate LumaCal

OptiCal Full

Automatic Lens Calibration

Vision Model 140/150 Owner’s Operating Manual

57

Page 69
Image 69