Installation

Yaw Adjust: Loosen the Yaw/X-Adjustment Levers to allow the lens to pivot freely from side to side. Then, angle the lens to even out any left-right pincushion distortion:

Anamorphic Lens (Top View)

Correct Position

Wrong Position

Once the proper lens angle has been set, firmly tighten the Yaw/X-Adjustment Levers to secure the lens in place.

Geometry:

1.Input an anamorphic cross-hatch test pattern to the VHD Controller.

2.Loosen the three Lens Rotation Set Screws (shown

at right) on the lens adapter plate just enough to allow it to rotate freely.