Vidikron 140/150 manual Rvr

Models: 140/150

1 114
Download 114 pages 1.1 Kb
Page 95
Image 95

Maintenance and Troubleshooting

13.Press ENTER to accept the change. This adds the new lamp serial number to the Lamp History menu and resets the Lamp Hours timer to “0.” Lamp Mode and Lamp Limit remain as they were for the previous lamp and can be changed at any time.

Lamp Adjust

Lamp Hours

147

Lamp S/N

123456789

1. Lamp Message

2.Lamp Limit 1000

3. Lamp Mode Power

4.Power 500

5.

Intensity

0

6.

RVR

3

7.

Lamp History

 

8.Change Lamp

9. Reserved

Figure 5-5. Recording the Serial Number of a New Lamp

Always record the serial number of a new lamp. Do this only if you have

Note

just installed a new lamp. This will ensure that the lamp timer is not reset

 

 

 

 

on an old lamp and that the number of hours logged on the lamp is

 

 

accurate.

 

 

Whenever you replace the lamp – or more often if the projector is installed in an extremely

Filter Replacement

dusty environment – you should also replace the two filters located at the front and right

 

side of the projector.

 

 

 

1. Loosen the six screws holding right side filter access

Right Side Filter

 

panel in place. Then, remove the panel.

Access Cover

 

2.Loosen the screw holding front filter access panel in place. Then, remove the panel.

3.Pull the filters out of the projector and discard. Do not reuse filters.

4.Insert the new filters with the wired side in.

5.Replace the filter access panels and tighten the screws to secure them.

Front Filter Access Cover

Vision Model 140/150 Owner’s Operating Manual

83

Page 95