Operation

Gamut

 

Settings

 

 

Manual

 

White

x:312

y:329

Y:045

 

 

Red

x:640

y:330

Y:015

 

 

Green

x:300

y:600

Y:022

 

 

Blue

x:150

y:060

Y:018

 

 

D. White

x:312

y:329

Y:045

 

 

Enter

 

 

 

 

 

Save

 

 

 

 

 

Color Temp.

 

6500

 

 

 

 

 

 

 

White

x:000 y:000 Y: 000

 

 

Changing either or both of these numbers changes the hue of the color and relocates the “triangle” for possible colors. For example, changing the x/y coordinates for red moves the color closer to either orange or violet, which in turn affects all displayed colors having a red component.

To perform these adjustments, you will need a color analyzer (Sencore

Note

ColorPro 5000 software and ColorPro III sensor, or equivalent).

 

To adjust the gamut:

1.Select Gamut from the Advanced Options menu and press ENTER.

2.To do an automatic gamut adjustment, highlight “Enter” and press ENTER. If further calibration is necessary, continue with the next step.

3.Highlight “Settings” and press or to select “Manual.”

4.Highlight “White” and press ENTER. The Vision 65/75 displays a white field on the screen.

5.Using the color analyzer, measure the x and y coordinates for about 15 seconds. Make a note of the results.

6.Press EXIT or ENTER.

7.Highlight “White” and press .

8. Press ENTER to select the first digit of the x coordinate value for White (obtained in Step 5).

9.Press or repeatedly to set the digit.

10.Press to select the next digit; use the and buttons to change it.

11.Repeat Step 10 for the third digit.

12.Press ENTER.

13.Press to highlight the “y” coordinate value for White. Then, press ENTER to select the first digit.

14.Repeat Steps 9 through 12 to set the “y” coordinate value for White.

15.Press to highlight the “Y” coordinate value. Then press ENTER to select the first digit.

16.Repeat Steps 9 through 12 to set the “Y” coordinate value for White.

17.Press EXIT.

18. Repeat Steps 4 through 17 for Red, Green, Blue and D. White (Desired White).

19. Highlight “Save” and press ENTER.

To undo the effects of a previous calibration, highlight “Settings” and press or to select “Default.”

Reset to Defaults: To restore the ISF default image settings for the current input source ONLY, select Reset to Defaults and press the button to highlight “Yes.” Then, press ENTER.

62

Vidikron Vision Model 65/Model 75 Installation/Operation Manual

Page 78
Image 78
Vidikron Vision 65, Vision 75 operation manual Operation