Installation

Installing the Fixed CineWide

Figure 3-9shows the cylindrical (Rainier II/McKinley) lens base plate assembly for a

Base Plate (Cylindrical Lens)

 

Vision 65/CineWide or Vision 75/CineWide.

Ceiling Mount

Plate (part of

Ceiling Mount

Kit)

1 Screw, Phillips

Pan-Head, M6 x 1.0 x 12mm (4x)

2 Anamorphic Lens

Base Plate

3 Nylon Spacer, 5/8” diameter x 3/16” high (4x)

Figure 3-9. Vision 65/CineWide or Vision 75/CineWide with Rainier II/McKinley (Cylindrical) Lens Base Plate and Ceiling Mounting Plate - Exploded View

1.Place the projector upside down on a blanket or other soft surface.

2.Install a nylon spacer (item #3) at each mounting hole location.

3.Line up the four mounting holes on the CineWide base plate (item #2) with those on the bottom of the projector.

24

Vidikron Vision Model 65/Model 75 Installation/Operation Manual

Page 40
Image 40
Vidikron operation manual Vision 65/CineWide or Vision 75/CineWide