Before UsingBasics SectionAppendix Getting StartedReference
01X Owner’s Manual 121
Parameter Lists
■Dynamics ParametersCompressor
Threshold –54 dB–0 dB (0.1 dB step)
Ratio (x :1) x=1, 1.1, 1.3, 1.5, 1.7, 2, 2.5, 3, 3.5, 4, 5, 6, 8, 10, 20, ∞ (16 points)
Out gain 0 dB to +18 dB (0.1 dB step)
Knee Hard, 1, 2, 3, 4, 5 (6 points)
Attack 0 ms–120 ms (1 ms step)
Release
6 ms–46.1 s (160 points) @ 44.1 kHz
5 ms–42.3 s (160 points) @ 48 kHz
3 ms–23.0 s (160 points) @ 88.2 kHz
3 ms–21.2 s (160 points) @ 96 kHz
Expander
Threshold –54 dB to 0 dB (0.1 dB step)
Ratio (x :1) x=1, 1.1, 1.3, 1.5, 1.7, 2, 2.5, 3, 3.5, 4, 5, 6, 8, 10, 20, ∞ (16 points)
Out gain 0 dB to +18 dB (0.1 dB step)
Knee Hard, 1, 2, 3, 4, 5 (6 points)
Attack 0 ms–120 ms (1 ms step)
Release
6 ms–46.1 s (160 points) @ 44.1 kHz
5 ms–42.3 s (160 points) @ 48 kHz
3 ms–23.0 s (160 points) @ 88.2 kHz
3 ms–21.2 s (160 points) @ 96 kHz
Compander H
Threshold –54 dB to 0 dB (0.1 dB step)
Ratio (x :1) x=1, 1.1, 1.3, 1.5, 1.7, 2, 2.5, 3, 3.5, 4, 5, 6, 8, 10, 20 (15 points)
Out gain –18 dB to 0 dB (0.1 dB step)
Width 1 dB–90 dB (1 dB step)
Attack 0 ms–120 ms (1 ms step)
Release
6 ms–46.1 s (160 points) @ 44.1 kHz
5 ms–42.3 s (160 points) @ 48 kHz
3 ms–23.0 s (160 points) @ 88.2 kHz
3 ms–21.2 s (160 points) @ 96 kHz
Compander S
Threshold –54 dB to 0 dB (0.1 dB step)
Ratio (x :1) x=1, 1.1, 1.3, 1.5, 1.7, 2, 2.5, 3, 3.5, 4, 5, 6, 8, 10, 20 (15 points)
Out gain –18 dB to 0 dB (0.1 dB step)
Width 1 dB–90 dB (1 dB step)
Attack 0 ms–120 ms (1 ms step)
Release
6 ms–46.1 s (160 points) @ 44.1 kHz
5 ms–42.3 s (160 points) @ 48 kHz
3 ms–23.0 s (160 points) @ 88.2 kHz
3 ms–21.2 s (160 points) @ 96 kHz
Ducking
Threshold –54 dB–0 dB (0.1 dB step)
Range –70 dB–0 dB (1 dB step)
Attack 0 ms–120 ms (1 ms step)
Hold
0.02 ms–2.13 s (216 points) @ 44.1 kHz
0.02 ms–1.96 s (216 points) @ 48 kHz
0.01 ms–1.07 s (216 points) @ 88.2 kHz
0.01 ms–980 ms (216 points) @ 96 kHz
Decay
6 ms–46.1 s (160 points) @ 44.1 kHz
5 ms–42.3 s (160 points) @ 48 kHz
3 ms–23.0 s (160 points) @ 88.2 kHz
3 ms–21.2 s (160 points) @ 96 kHz
Gate
Threshold –54 dB–0 dB (0.1 dB step)
Range –70 dB–0 dB (1 dB step)
Attack 0 ms–120 ms (1 ms step)
Hold
0.02 ms–2.13 s (216 points) @ 44.1 kHz
0.02 ms–1.96 s (216 points) @ 48 kHz
0.01 ms–1.07 s (216 points) @ 88.2 kHz
0.01 ms–980 ms (216 points) @ 96 kHz
Decay
6 ms–46.1 s (160 points) @ 44.1 kHz
5 ms–42.3 s (160 points) @ 48 kHz
3 ms–23.0 s (160 points) @ 88.2 kHz
3 ms–21.2 s (160 points) @ 96 kHz