Before UsingBasics SectionAppendix Getting StartedReference
01X Owner’s Manual 147
Troubleshooting
■The pitch is wrong.• Is the 01X operating on the same sampling frequency as
the synchronized external device?...................................................... page 92, “Settings by mLAN Auto Connector” (Installation Guide)
• Is the master device operating in a stable way?
• Is an effect such as HQ.Pitch or Dual Pitch selected?.....................................................................................................................page 102
■The layer of 17-24 (mLAN9-16) cannot be used.• When the sampling rate is set to 96kHz/88.2kHz, the layer of 17 – 24 (mLAN) can not be selected..............................................page 40
■Cannot edit with Studio Manager.• Has the STUDIO MANAGER ID been set correctly?......................................................................................................................page 94
• Is Port 4 (Studio Manager) selected for Studio Manager data transmission/reception?............... Studio Manager Owner’s Manual (PDF)
■The Remote Control or Automation features do not work.• Is the correct DAW software selected in Remote Select?.................................................................................................................page 87
• Are the mLAN settings correct?........................................................................................................................................Installation Guide
• Are settings on the DAW correct?......................................................................................................................page 67, Installation Guide
• Is Port 1 selected for mLAN MIDI transmission/reception?..............................................................................page 67, Installation Guide
■Cannot change the wordclock.• Set this with the mLAN Auto Connector when using mLAN...........................“Settings by mLAN Auto Connector” (Installation Guide)
• Is the mLAN Auto Wordclock (AUTO W.CLK) setting appropriate?.............................................................................................. page 92
■Cannot install the driver.• Is the mLAN cable properly connected? Check the connection; disconnect the mLAN cable once, then insert it again.
■The mLAN connection does not work.• Has the driver been installed?............................................................................................................................................Installation Guide
• Is the mLAN cable properly connected? Check the connection; disconnect the mLAN cable once, then insert it again.
•(For Windows) Is mLAN set to “ON”? From the taskbar, right click on the mLAN Manager icon...............................Installation Guide
•(For Windows) When adding a new IEEE 1394 card, right click on the
mLAN Manager icon in the taskbar and select “ON.”......................................................................................................Installation Guide
• Is the ACTIVE lamp on the rear panel of the 01X lit (in blue)? If it is not lit, check the followings:
• In mLAN Driver Setup (from taskbar, right click on the mLAN Manager icon,
then “Driver Setup”), is the Status indicator blue? If not, restart the 01X and
re-enable connection by using mLAN Auto Connector....................................................................................................Installation Guide
• Is mLAN AUTO W.CLK (Auto Wordclock) on the 01X set to “ENABLE”?...................................................................................page 92
• Has connection been enabled with mLAN Auto Connector?
Re-enable connection if necessary.....................................................................“Settings by mLAN Auto Connector” (Installation Guide)
•Have you changed the device? Even if the model is the same,
if the actual device is different, it is necessary to re-enable
connection by using Auto Connector.................................................................“Settings by mLAN Auto Connector” (Installation Guide)
• Is there a loop connection? Check the cabling and make sure none of the devices are connected in a loop.
Computer Computer
01X
01X
: IEEE 1394-equipped device
Example of loop connection