Recalling the Registered Panel Setups

4 Use the [E] button to determine how Registration Sequence behaves when reaching the end of the sequence (SEQUENCE END).

STOP .....................

Pressing the TAB [®] button or the “advance” pedal has

 

no effect. The sequence is “stopped.”

TOP .......................

The sequence starts again at the beginning.

NEXT BANK...........

The sequence automatically moves to the beginning of

 

the next Registration Memory Bank in the same folder.

5 Program the Sequence order.

The numbers shown at the lower part of the display correspond to the REGISTRATION MEMORY [1]–[8] buttons on the panel.

Program the Sequence order from left to right.

Press one of the REGISTRATION MEMORY [1]–[8] button on the panel, then press the [6π†] (INSERT) button to input the number.

Replacing the number

Press the [5π†] (REPLACE) button to replace the number at the cursor position with the currently selected Registration Memory number.

Deleting the number

Press the [7π†] (DELETE) button to delete the number at the cursor position.

Deleting all numbers

Press the [8π†] (CLEAR) button to delete all numbers in the sequence.

6 Press the [F] button to turn the Registration Sequence function on.

7 Press the [DIRECT ACCESS] button, then the [EXIT] button to return to the Main display and confirm whether the Registration Memory numbers are called up according to the sequence programmed above.

Use the TAB [®] button to call up the Registration Memory numbers in the order of the sequence, or use the TAB [] button to call them up in reverse order. The TAB [][®] buttons can only be used for Registration Sequence when the Main display is called up.

When pedal operation has been set in step 3, you can use a pedal to select the Registration Memory numbers in order. The pedal can be used for Reg- istration Sequence no matter which display is called up (except for the dis- play in step 3).

The Registration Sequence is indicated at the top right of the Main display, letting you confirm the currently selected number.

Saving the Registration Sequence Settings

The settings for the Sequence order and how Registration Sequence behaves when reaching the end of the sequence (SEQUENCE END) are included as part of the Registration Memory Bank file. To store your newly programmed Registration Sequence, save the current Registration Memory Bank file.

1 Press the REGIST BANK [+] and [–] buttons simultaneously to call up the REGISTRATION BANK Selection display.

2 Press the [6] button to save the Bank file (page 67).

CAUTION

Settings in the REGISTRATION SEQUENCE display are automatically saved to the instrument when you exit from this display. However, if you turn the power off without exiting from this display, the settings will be lost.

Returning to the first Sequence in one action

In the Main display, press the TAB [] and [®] buttons simul- taneously. This cancels the currently selected Sequence number (the box indicator at the top right goes out). The first Sequence will be selected by pressing one of the TAB [][®] buttons or by pressing the pedal.

CAUTION

Keep in mind that all Registration Sequence data is lost when changing Registration Memory Banks, unless you’ve saved it with the Registration Memory Bank file.

Setups Panel Custom Recalling and Registering