68Configuration

Control Panel LCD Display

 

Table 11 • Printer Parameters, Level 3 (Page 4 of 9)

 

 

Parameter

Explanation

 

 

CONTROL CHAR

Set Control Character

(ZPL mode only)

The printer looks for this two-digit hexadecimal character to indicate the

 

start of a ZPL/ZPL II control instruction.

 

Note • Do not use the same hexadecimal value for the control,

 

command, and delimiter character. The printer must see different

 

characters to work properly.

 

Range: 00 to FF

 

Default Value: 7E (tilde—displayed as an arrow)

 

To modify this parameter:

 

• To increase the value, press the up arrow.

 

• To decrease the value, press the down arrow.

 

 

COMMAND CHAR

Set Command Character

(ZPL mode only)

The command prefix is a two-digit hexadecimal value used as a parameter

 

place marker in ZPL/ZPL II format instructions. The printer looks for this

 

two-digit hexadecimal character to indicate the start of a ZPL/ZPL II

 

format instruction. See the ZPL II Programming Guide Volume I for more

 

information.

 

Note • Do not use the same hexadecimal value for the control,

 

command, and delimiter character. The printer must see different

 

characters to work properly.

 

Range: 00 to FF

 

Default Value: 5E (caret)

 

To modify this parameter:

 

• To increase the value, press the up arrow.

 

• To decrease the value, press the down arrow.

 

 

DELIM. CHAR

Set Delimiter Character

(ZPL mode only)

The delimiter character is a two-digit hexadecimal value used as a

 

parameter place marker in ZPL/ZPL II format instructions. See the ZPL II

 

Programming Guide Volume I for more information.

 

Note • Do not use the same hexadecimal value for the control,

 

command, and delimiter character. The printer must see different

 

characters to work properly.

 

Range: 00 to FF

 

Default Value: 2C (comma)

To modify this parameter:

To increase the value, press the up arrow.

To decrease the value, press the down arrow.