Configuration

 

79

 

 

 

Control Panel Parameters

 

 

Table 15 • Printer Parameters, Password Level 3 (Page 3 of 10)

 

 

 

Parameter

Explanation

 

 

BAUD

Set Baud

 

 

The baud setting of the printer must match the baud setting of the host

 

computer for accurate communications to take place. Select the value that

 

matches the one being used by the host computer.

 

Selections (ZPL, APL-I,APL-D):300, 600, 1200, 2400, 4800, 9600,

 

14400, 19200, 28800, 38400, 57600, 115200

 

 

 

 

Selections (EPL): 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200

 

Default Value: 9600

 

To modify this parameter:

 

• Press the up or down arrow to scroll through the selections.

 

 

 

DATA BITS

Set Data Bits

 

The data bits of the printer must match the data bits of the host computer

 

for accurate communications to take place. Set the data bits to match the

 

setting being used by the host computer.

 

Note • Code Page 850 requires the data bits to be set to 8 bits.

 

Selections: 7 BITS, 8 BITS

 

Default Value: 8 BITS

 

To modify this parameter:

 

• Press the up or down arrow to scroll through the selections.

 

 

 

STATUS RESPONSE

Send APL-I Status Response

(APL-I mode only)

Determines if a response is sent after inquiry commands.

 

Selections: ON, OFF

 

Default Value: ON

 

To modify this parameter:

 

• Press the up or down arrow to scroll through the selections.

 

 

 

PARITY

Set Parity

 

The parity of the printer must match the parity of the host computer for

 

accurate communications to take place. Select the parity that matches the

 

one being used by the host computer.

 

Selections: NONE, ODD, EVEN

 

Default Value: NONE

 

To modify this parameter:

 

• Press the up or down arrow to scroll through the selections.

 

 

 

 

 

6/15/09

S4M User Guide

13290L-004 Rev. A