Amp simulator settings: pages 1, 2

The 8080 incorporates an amp simulator that is separate from the effect modules in the patches. Using the amp simulator yields realistic guitar amp sound also when listening through headphones or audio speakers.

Pages 1 and 2 of the Utility mode serve for setting amp simulator parameters.

AMP

COL= qLVL=w q

 

 

 

 

 

Parameters

Comment

Values

 

 

 

 

w

q COL(Color)

Sets the amplifier type.

OFF, 1 – 3

1

LoG= eHiG=r

MIN

3

4

MIN

MAX

 

 

 

MAX 1

2

 

 

 

PAGE 1

 

e

 

 

 

 

r

w LVL(Level)

Sets the output level.

0 – 100

 

 

 

MIN

MAX

 

MIN

MAX

 

 

 

 

UTILITY

 

 

 

 

 

 

e LoG(Low EQ Gain)

Adjusts the low-range equalizer.

-10 – +10

 

PAGE

 

 

 

 

 

 

PAGE 2

 

t

 

 

 

 

y

r HiG(High EQ Gain)

Adjusts the high-range equalizer.

-10 – +10

AMP

CAB= tDPT=y

MIN

MAX 1

2

MIN

MAX

t CAB(Cabinet)

Selects the speaker cabinet type.

COM, CMB, STK

 

3

4

 

 

y DPT(Depth)

Adjusts the depth of the cabinet effect.

0 – 100

2

 

 

 

 

 

 

 

 

 

MIN

MAX

 

MIN

MAX

 

 

 

 

 

 

 

 

 

 

HINT

The following settings are available for the COL parameter.

OFF: Amp simulator disabled

1:Amplifier with flat frequency response

2:Vintage amplifier with pronounced midrange

3:Modern amplifier with prominent high end and low end

The following settings are available for the CAB parameter. COM: Compact

CMB: Combo

STK: Stack

USER FUNCTION switch settings: page 3

The USER FUNCTION switch can be programmed to perform any of the four functions listed below.

PATCH ••••••••••••••••••••••••••••••• Select the patch set with the PAT parameter.

BANK •••••••••••••••••••••••••••••••••••• Select the bank set with the BNK parameter.

MANUAL ••••••••••••••••••••• Switch between Play mode and Manual mode.

PRESET ••••••••••••••••••••••••••• Switch between PRESET groups A/B/C.

Page 3 of the Utility mode serves to select the USER FUNCTION switch function.

 

 

 

 

 

 

Parameters

Comment

Values

PAGE 3

 

 

 

 

 

q USER FUNCTION=

Function to be activated by USER

PATCH, BANK,

 

 

 

 

 

 

FUNCTION switch.

MANUAL,

 

 

 

 

 

 

 

USER FUNCTION=

q

 

 

 

 

q

PRESET (Factory default: PRESET)

3 BNK= w PAT=e

MIN

MAX 1

2 MIN

MAX

w BNK(Bank Number)

Sets the bank to be called up by the USER

 

 

3

4

 

 

 

 

w

 

 

 

e

FUNCTION switch.

U0 - P9

 

 

MIN

MAX

MIN

MAX

 

 

 

ePAT(Patch Number) Sets the patch to be called up by

the USER FUNCTION switch.

U01 – P95

Operation Advanced