Amp simulator settings: pages 1, 2
The 8080 incorporates an amp simulator that is separate from the effect modules in the patches. Using the amp simulator yields realistic guitar amp sound also when listening through headphones or audio speakers.
Pages 1 and 2 of the Utility mode serve for setting amp simulator parameters.
AMP | COL= q | LVL=w q |
|
|
|
|
| Parameters | Comment | Values |
|
|
|
| w | q COL(Color) | Sets the amplifier type. | OFF, 1 – 3 | |||
1 | LoG= e | HiG=r | MIN | 3 | 4 | MIN | MAX | |||
|
|
| MAX 1 | 2 |
|
|
| |||
PAGE 1 |
| e |
|
|
|
| r | w LVL(Level) | Sets the output level. | 0 – 100 |
|
|
| MIN | MAX |
| MIN | MAX |
|
|
|
| UTILITY |
|
|
|
|
|
| e LoG(Low EQ Gain) | Adjusts the | |
| PAGE |
|
|
|
|
|
| |||
PAGE 2 |
| t |
|
|
|
| y | r HiG(High EQ Gain) | Adjusts the | |
AMP | CAB= t | DPT=y | MIN | MAX 1 | 2 | MIN | MAX | t CAB(Cabinet) | Selects the speaker cabinet type. | COM, CMB, STK |
| 3 | 4 |
|
| y DPT(Depth) | Adjusts the depth of the cabinet effect. | 0 – 100 | |||
2 |
|
|
|
|
|
|
| |||
|
| MIN | MAX |
| MIN | MAX |
|
|
| |
|
|
|
|
|
|
|
HINT
The following settings are available for the COL parameter.
OFF: Amp simulator disabled
1:Amplifier with flat frequency response
2:Vintage amplifier with pronounced midrange
3:Modern amplifier with prominent high end and low end
The following settings are available for the CAB parameter. COM: Compact
CMB: Combo
STK: Stack
USER FUNCTION switch settings: page 3
The USER FUNCTION switch can be programmed to perform any of the four functions listed below.
•PATCH ••••••••••••••••••••••••••••••• Select the patch set with the PAT parameter.
•BANK •••••••••••••••••••••••••••••••••••• Select the bank set with the BNK parameter.
•MANUAL ••••••••••••••••••••• Switch between Play mode and Manual mode.
•PRESET ••••••••••••••••••••••••••• Switch between PRESET groups A/B/C.
Page 3 of the Utility mode serves to select the USER FUNCTION switch function.
|
|
|
|
|
| Parameters | Comment | Values |
PAGE 3 |
|
|
|
|
| q USER FUNCTION= | Function to be activated by USER | PATCH, BANK, |
|
|
|
|
|
| FUNCTION switch. | MANUAL, | |
|
|
|
|
|
|
| ||
USER FUNCTION= | q |
|
|
|
| q | PRESET (Factory default: PRESET) | |
3 BNK= w PAT=e | MIN | MAX 1 | 2 MIN | MAX | w BNK(Bank Number) | Sets the bank to be called up by the USER |
| |
| 3 | 4 |
|
| ||||
|
| w |
|
|
| e | FUNCTION switch. | U0 - P9 |
|
| MIN | MAX | MIN | MAX |
|
|
|
ePAT(Patch Number) Sets the patch to be called up by
the USER FUNCTION switch. | U01 – P95 |
Operation Advanced
33■