Chapter 30 Cluster Management
Figure 133 Management > Clustering Management > Configuration
The following table describes the labels in this screen.
Table 93 Management > Clustering Management > Configuration
LABEL | DESCRIPTION |
Clustering Manager |
|
|
|
Active | Select Active to have this Switch become the cluster manager switch. A cluster |
| can only have one manager. Other (directly connected) switches that are set to |
| be cluster managers will not be visible in the Clustering Candidates list. If a |
| switch that was previously a cluster member is later set to become a cluster |
| manager, then its Status is displayed as Error in the Cluster Management |
| Status screen and a warning icon ( ) appears in the member summary list |
| below. |
|
|
Name | Type a name to identify the Clustering Manager. You may use up to 32 |
| printable characters (spaces are allowed). |
|
|
VID | This is the VLAN ID and is only applicable if the Switch is set to 802.1Q VLAN. |
| All switches must be directly connected and in the same VLAN group to belong |
| to the same cluster. Switches that are not in the same VLAN group are not |
| visible in the Clustering Candidates list. This field is ignored if the Clustering |
| Manager is using |
|
|
| 225 |
|
|