Chapter 7 Basic Setting
Figure 25 Basic Setting > System Info
The following table describes the labels in this screen.
Table 8 Basic Setting > System Info
LABEL | DESCRIPTION |
System Name | This field displays the descriptive name of the Switch for identification purposes. |
|
|
ZyNOS F/W | This field displays the version number of the Switch's current firmware including the |
Version | date created. |
|
|
Ethernet | This field refers to the Ethernet MAC (Media Access Control) address of the Switch. |
Address |
|
|
|
PoE Status (This section is available for the PWR model only.) | |
|
|
Total Power | This field displays the total power the Switch can provide to the connected PoE- |
| enabled devices on the PoE ports. |
|
|
Consuming | This field displays the amount of power the Switch is currently supplying to the |
Power | connected |
|
|
Allocated | This field displays the total amount of power the Switch has reserved for PoE after |
Power | negotiating with the connected PoE device(s). |
|
|
Remaining | This field displays the amount of power the Switch can still provide for PoE. |
Power |
|
| Note: The Switch must have at least 16 W of remaining power in order |
| to supply power to a PoE device; even if the PoE device |
| requested for a lower power supply than 16W. |
|
|
Hardware Monitor | |
|
|
Temperature | The Switch has temperature sensors that are capable of detecting and reporting if the |
Unit | temperature rises above the threshold. You may choose the temperature unit |
| (Centigrade or Fahrenheit) in this field. |
|
|
Temperature | MAC, CPU and LOCAL refer to the location of the temperature sensors on the Switch |
| printed circuit board. |
|
|