cgmSys | MIB Description |
|
|
Table 5-5 cgmControl Elements (continued)
OID | MIB Object | Description | Access | |
|
|
|
| |
.1.1.41 | cgmCLK2OutputFrequency | The output frequency of CLK2: | r/w | |
|
| 0 | - CLK2 output disabled |
|
|
| 1 | - 19.44 MHz |
|
|
| Default value is (1). |
| |
|
|
|
| |
.1.1.42 | cgmCLK3OutputFrequency | Not supported on | r/w | |
|
|
|
| |
.1.1.43 | cgmCLK1OutputFramePulse | The output frame pulse of the T1 clock: | r/w | |
|
| 0 | - Not inverted, not pulsed |
|
|
| 1 | - Not inverted, pulsed |
|
|
| 2 | - Inverted, not pulsed |
|
|
| 3 | - Inverted, pulsed |
|
|
| Default value is (0). |
| |
|
|
|
| |
.1.1.44 | cgmT4ClkSquelch | When set to 0 (enable) the output of the T4 PLL |
| |
|
| is squelched if no valid input is selected. |
| |
|
| If set to 1 (disable) an output is provided in any |
| |
|
| case. |
| |
|
|
|
|
|
5.3cgmSys
The cgmSys branch contains the following information:
zcgmEventTable - for details refer to Table
zVarious MIB objects that are described in Table
For a description on how to use these objects refer to Configure Parameters for Event Handling on page 44, Perform Firmware/Software Upgrade on page 42.
The cgmEventTable (OID:.1.3.6.1.4.1.3656.8152.1.3.1) uses cgmEventNumber as index. The elements of the trap definiton cgmLogEvent (OID:.1.3.6.1.4.1.3656.8152.1.2.0.1) is identical to the elements defined in cgmEventTable.
Table 5-6 cgmEventTable
| OID | MIB Object | Description | Access | |
|
|
|
|
| |
| .1.3.1.1.2 | cgmEventTime | System time stamp when event occurred (this is the | r | |
|
|
| module's |
| |
|
|
|
|
| |
| .1.3.1.1.3 | cgmEventSeverity | The event's severity level | r | |
|
|
| 1. | Critical (0): An error has occurred which needs |
|
|
|
| immediate attention. |
| |
|
|
| 2. | Warnings (1): An error has occurred which may affect |
|
|
|
| board operation but does not require immediate attention. |
| |
|
|
| 3. | Events (2): An event occurred in a board subsystem |
|
|
|
| which may need attention (e.g. the PLL gained lock). |
| |
|
|
| 4. | Information (3): Various information messages helpful |
|
|
|
| for troubleshooting or monitoring the state of the CGM |
| |
|
|
| module. |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 55 |