Emerson PMC-CGM manual CgmBitsTable, CgmControl MIB Description

Page 49

cgmControl

MIB Description

 

 

The cgmBitsTable (OID: .1.3.6.1.4.1.3656.8152.1.1.2) uses bitsInterfaceNumber as index.

Table 5-4 cgmBitsTable

OID

MIB Object

Description

Access

 

 

 

 

.1.1.2.1.1

bitsInterfaceNumber

0 for BITS interface 1

r

 

 

1 for BITS interface 2

 

 

 

 

 

.1.1.2.1.2

bitsEnable

Enables (0) or disables (1) a BITS interface.

r/w

 

 

Enabling the interface also applies various default

 

 

 

parameters, depending on the operation mode

 

 

 

defined in <cgmInterfaceMode>:

 

 

 

E1/SDH Mode:

 

 

 

- <dsx1LineType> is <dsx1E1>

 

 

 

- <dsx1LineCode> is <dsx1HDB3>

 

 

 

-< bitsLiuE1Lbo> is <o120>

 

 

 

T1/Sonet Mode:

 

 

 

- <dsx1LineType> is <dsx1D4>

 

 

 

- <dsx1LineCode> is <dsx1B8ZS>

 

 

 

- <bitsLiuT1Lbo> is <ft0to133>

 

 

 

Default value is enabled (0).

 

 

 

 

 

.1.1.2.1.3

bitsTxEnable

Enables/disables the line interface transmitter.

r/w

 

 

Default value is enabled (1).

 

 

 

 

 

.1.1.2.1.4

dsx1LineType

Line type configuration. The allowed settings

r/w

 

 

depend on the module’s interface mode:

 

 

 

Applicable for E1:

 

 

 

- dsx1E1 (value 4, default)

 

 

 

- dsx1E1CRCMF (value 7)

 

 

 

- dsx1E1G703 (value 12)

 

 

 

- dsx1E1UnframedAll1 (value 9) (Setting this line

 

 

 

type is equivalent to Transmit AIS in E1 mode.)

 

 

 

- dsx1E1UnframedAlt (value 11, 0101… pattern)

 

 

 

Applicable for T1:

 

 

 

- dsx1D4 (value 3, default)

 

 

 

- dsx1ESF (value 2)

 

 

 

- dsx1UnframedAll1 (value 8)

 

 

 

- dsx1UnframedAlt (value 10, 0101.. pattern)

 

 

 

 

 

.1.1.2.1.5

dsx1LineCode

E1/T1 Line code.

r/w

 

 

Applicable for E1:

 

 

 

- dsx1HDB3 (default)

 

 

 

- dsx1AMI

 

 

 

Applicable for T1:

 

 

 

- dsx1B8ZS (default)

 

 

 

- dsx1AMI

 

 

 

 

 

PMC-CGM Installation and Use (6806800D53C)

49

Image 49
Contents PMC-CGM Contact Address Contents Contents List of Tables List of Tables PMC-CGM Installation and Use 6806800D53C Location of PMC Slot on ATCA-F103 List of FiguresList of Figures PMC-CGM Installation and Use 6806800D53C About this Manual Overview of ContentsAbbreviations RTM About this Manual Abbreviation DefinitionNotation Description ConventionsBold Comments and Suggestions Summary of ChangesAbout this Manual Notation Description Part Number Publication Date DescriptionElectrical Interference Safety NotesSafety Notes InstallationOperation Cabling and Connectors Configuration SwitchesEnvironment Safety Notes PMC-CGM Installation and Use 6806800D53C EMV SicherheitshinweiseSicherheitshinweise Kabel und Stecker SchaltereinstellungenUmweltschutz Sicherheitshinweise PMC-CGM Installation and Use 6806800D53C Introduction FeaturesStandard Compliances and Clocking Standards Standard CompliancesIntroduction Standard Compliances Standard DescriptionAvailable Board Variants Ordering InformationOrdering InformationIntroduction Order Number DescriptionPage Before Installation Hardware Preparation and InstallationOverview Unpacking and Inspecting the ModuleRequirements Hardware Preparation and Installation RequirementsRequirementsHardware Preparation and Installation DC Module Power RequirementsFeature Operating Non-Operating packed state Feature ValueSwitch Location Configuring the ModuleSwitch Settings Installing and Removing the ModuleSwitch Installation Procedure Hardware Upgrades and AcessoriesRemoval Procedure Front Panel Connectors and LEDs Controls, LEDs and ConnectorsLayout Controls, LEDs and Connectors Bits Interface Connectors Bits Interface ConnectorsLEDs LEDs Controls, LEDs and ConnectorsName Description LED DescriptionAccessing the PMC-CGM Access and ConfigurationAccess and Configuration Cabling AccessCabling Configuring the PMC-CGM Using a MIB BrowserMIB Browser Settings Using a MIB Browser Access and ConfigurationDefine Snmp Trap Destinations Define IP Address of the Protection Partner ModuleDefining the IP address of the protection partner module Defining Snmp Trap DestinationsConfigure the Bits Interface Configure the Interface ModeConfiguring the interface mode Configuring the Bits interfaceSetup Multi-Shelf Configuration Configure Initial Master/Slave RoleConfiguring the initial master/slave roles Setting up a multi-shelf configurationConfiguring the reference clock source for the T0/T4 path Configure the Reference ClockConfigure the Reference Clock Access and Configuration Upgrading the firmware/software Perform Firmware/Software UpgradeResetting the PMC-CGM via Snmp Reset the PMC-CGMReset the PMC-CGM Access and Configuration Configuring event handling parameters Configure Parameters for Event HandlingPMC-CGM Installation and Use 6806800D53C Page CgmControl MIB DescriptionMIB Structure CgmInputTableInput Assignments DefaultMIB DescriptioncgmControl Instance CgmInputNumber CgmInputName CgmInputFrequencyCgmControl MIB Description CgmBitsTableNot yet supported CgmControlMIB Description Is present. This should only be set for test purposes CgmControl Elements Input When in nonrevertive operation 1, a selectedMIB Description CgmControl CgmEventTable CgmSysCgmSys MIB Description Not supported on PMC-CGMMIB DescriptioncgmSys Event Codes and SeverityCode Severity Description CgmSysMIB Description CgmSys Objects New firmware image MIB Description CgmClkDist CgmClkDistCgmClkDist MIB Description CgmClkDist ObjectsNot applicable for PMC-CGM PLL Related Specifications Emerson Network Power Embedded Computing DocumentsRelated Documentation Document Title Publication NumberPage Index Sonet