Emerson PMC-CGM manual Configure Initial Master/Slave Role, Setup Multi-Shelf Configuration

Page 40

Access and Configuration

Configure Initial Master/Slave Role

 

 

4.4.5Configure Initial Master/Slave Role

After the initial configuration, the master/slave roles are handled by the DPLL software that runs on the processor of the PMC-CGM.

Configuring the initial master/slave roles

To configure the initial master/slave roles, proceed as follows:

1.Start SNMP manager or MIB browser.

2.Connect to the PMC-CGM using one of its IP addresses.

3.Check the master/slave role of the current PMC-CGM module in the cgmProtectionState object OID:.1.3.6.1.4.1.3656.8152.1.1.19.0.

The following values are possible: 0 (standaloneMaster: Communication with the partner is not possible and the module is running in master mode.), 1 (slave), 2 (master).

4.Adapt the master/slave role of the current PMC-CGM module, if necessary, in the cgmProtectionCmd object OID:.1.3.6.1.4.1.3656.8152.1.1.20.0.

The following values are possible:

0 - Attempt to become master. This is only possible if a valid clock input is present. 1 - Give up mastership to the protection partner. This is only possible if the partner (slave) has a valid input other than MS_SYNC.

5.Check whether the role change was successful in the cgmProtectionState object OID:.1.3.6.1.4.1.3656.8152.1.1.19.0.

4.4.6Setup Multi-Shelf Configuration

You have to define the number of extension shelves, up to two extension shelves are possible.

Setting up a multi-shelf configuration

To set up a multi-shelf configuration, proceed as follows:

1.Start SNMP manager or MIB browser.

2.Connect to the PMC-CGM using one of its IP addresses.

3.Go to cgmExtChConnection object OID:.1.3.6.1.4.1.3656.8152.1.4.11.0.

4.Select the properties of the connections to extension chassis 2 and 3. The following values are possible:

Single Chassis (0) - default value Chassis 2 in extension mode (1) Chassis 3 in extension mode (3)

Chassis 2&3 in extension mode (5)

40

PMC-CGM Installation and Use (6806800D53C)

Image 40
Contents PMC-CGM Contact Address Contents Contents List of Tables List of Tables PMC-CGM Installation and Use 6806800D53C List of Figures Location of PMC Slot on ATCA-F103List of Figures PMC-CGM Installation and Use 6806800D53C About this Manual Overview of ContentsAbbreviations About this Manual Abbreviation Definition RTMNotation Description ConventionsBold Summary of Changes Comments and SuggestionsAbout this Manual Notation Description Part Number Publication Date DescriptionSafety Notes Electrical InterferenceSafety Notes InstallationOperation Cabling and Connectors Configuration SwitchesEnvironment Safety Notes PMC-CGM Installation and Use 6806800D53C Sicherheitshinweise EMVSicherheitshinweise Kabel und Stecker SchaltereinstellungenUmweltschutz Sicherheitshinweise PMC-CGM Installation and Use 6806800D53C Features IntroductionStandard Compliances Standard Compliances and Clocking StandardsIntroduction Standard Compliances Standard DescriptionOrdering Information Available Board VariantsOrdering InformationIntroduction Order Number DescriptionPage Hardware Preparation and Installation Before InstallationOverview Unpacking and Inspecting the ModuleHardware Preparation and Installation Requirements RequirementsDC Module Power Requirements RequirementsHardware Preparation and InstallationFeature Operating Non-Operating packed state Feature ValueConfiguring the Module Switch LocationSwitch Settings Installing and Removing the ModuleSwitch Installation Procedure Hardware Upgrades and AcessoriesRemoval Procedure Front Panel Connectors and LEDs Controls, LEDs and ConnectorsLayout Bits Interface Connectors Controls, LEDs and Connectors Bits Interface ConnectorsLEDs Controls, LEDs and Connectors LEDsLED Description Name DescriptionAccess and Configuration Accessing the PMC-CGMAccess and Configuration Cabling AccessCabling Using a MIB Browser Configuring the PMC-CGMMIB Browser Settings Using a MIB Browser Access and ConfigurationDefine IP Address of the Protection Partner Module Define Snmp Trap DestinationsDefining the IP address of the protection partner module Defining Snmp Trap DestinationsConfigure the Interface Mode Configure the Bits InterfaceConfiguring the interface mode Configuring the Bits interfaceConfigure Initial Master/Slave Role Setup Multi-Shelf ConfigurationConfiguring the initial master/slave roles Setting up a multi-shelf configurationConfiguring the reference clock source for the T0/T4 path Configure the Reference ClockConfigure the Reference Clock Access and Configuration Perform Firmware/Software Upgrade Upgrading the firmware/softwareResetting the PMC-CGM via Snmp Reset the PMC-CGMReset the PMC-CGM Access and Configuration Configure Parameters for Event Handling Configuring event handling parametersPMC-CGM Installation and Use 6806800D53C Page MIB Description CgmControlMIB Structure CgmInputTableDefault Input AssignmentsMIB DescriptioncgmControl Instance CgmInputNumber CgmInputName CgmInputFrequencyCgmBitsTable CgmControl MIB DescriptionNot yet supported CgmControlMIB Description Is present. This should only be set for test purposes Input When in nonrevertive operation 1, a selected CgmControl ElementsMIB Description CgmControl CgmSys CgmEventTableCgmSys MIB Description Not supported on PMC-CGMMIB DescriptioncgmSys Event Codes and SeverityCode Severity Description CgmSysMIB Description CgmSys Objects New firmware image CgmClkDist MIB Description CgmClkDistCgmClkDist MIB Description CgmClkDist ObjectsNot applicable for PMC-CGM PLL Emerson Network Power Embedded Computing Documents Related SpecificationsRelated Documentation Document Title Publication NumberPage Index Sonet