Emerson PMC-CGM manual Conventions, Notation Description, Bold

Page 11

About this Manual

Abbreviation

Definition

 

 

TPE

Twisted-Pair Ethernet

 

 

UL

Underwriters Laboratories Incorporated

 

 

VCCI

Voluntary Control Council for Interference

 

 

VLAN

Virtual Local Area Network

 

 

Conventions

The following table describes the conventions used throughout this manual.

Notation

Description

 

 

0x00000000

Typical notation for hexadecimal numbers (digits

 

are 0 through F), for example used for addresses

 

and offsets

 

 

0b0000

Same for binary numbers (digits are 0 and 1)

 

 

bold

Used to emphasize a word

 

 

Screen

Used for on-screen output and code related

 

elements or commands in body text

 

 

Courier + Bold

Used to characterize user input and to separate it

 

from system output

 

 

Reference

Used for references and for table and figure

 

descriptions

 

 

File > Exit

Notation for selecting a submenu

 

 

<text>

Notation for variables and keys

 

 

[text]

Notation for software buttons to click on the screen

 

and parameter description

 

 

...

Repeated item for example node 1, node 2, ...,

 

node 12

 

 

.

Omission of information from example/command

.

that is not necessary at the time being

 

.

 

 

 

..

Ranges, for example: 0..4 means one of the

 

integers 0,1,2,3, and 4 (used in registers)

 

 

Logical OR

 

 

PMC-CGM Installation and Use (6806800D53C)

11

Image 11
Contents PMC-CGM Contact Address Contents Contents List of Tables List of Tables PMC-CGM Installation and Use 6806800D53C Location of PMC Slot on ATCA-F103 List of FiguresList of Figures PMC-CGM Installation and Use 6806800D53C Abbreviations Overview of ContentsAbout this Manual RTM About this Manual Abbreviation DefinitionBold ConventionsNotation Description Part Number Publication Date Description Summary of ChangesComments and Suggestions About this Manual Notation DescriptionElectrical Interference Safety NotesOperation InstallationSafety Notes Environment Configuration SwitchesCabling and Connectors Safety Notes PMC-CGM Installation and Use 6806800D53C EMV SicherheitshinweiseSicherheitshinweise Umweltschutz SchaltereinstellungenKabel und Stecker Sicherheitshinweise PMC-CGM Installation and Use 6806800D53C Introduction FeaturesStandard Description Standard CompliancesStandard Compliances and Clocking Standards Introduction Standard CompliancesOrder Number Description Ordering InformationAvailable Board Variants Ordering InformationIntroductionPage Unpacking and Inspecting the Module Hardware Preparation and InstallationBefore Installation OverviewRequirements Hardware Preparation and Installation RequirementsFeature Value DC Module Power RequirementsRequirementsHardware Preparation and Installation Feature Operating Non-Operating packed stateSwitch Location Configuring the ModuleSwitch Installing and Removing the ModuleSwitch Settings Removal Procedure Hardware Upgrades and AcessoriesInstallation Procedure Layout Controls, LEDs and ConnectorsFront Panel Connectors and LEDs Controls, LEDs and Connectors Bits Interface Connectors Bits Interface ConnectorsLEDs LEDs Controls, LEDs and ConnectorsName Description LED DescriptionAccessing the PMC-CGM Access and ConfigurationCabling AccessAccess and Configuration Cabling Using a MIB Browser Access and Configuration Using a MIB BrowserConfiguring the PMC-CGM MIB Browser SettingsDefining Snmp Trap Destinations Define IP Address of the Protection Partner ModuleDefine Snmp Trap Destinations Defining the IP address of the protection partner moduleConfiguring the Bits interface Configure the Interface ModeConfigure the Bits Interface Configuring the interface modeSetting up a multi-shelf configuration Configure Initial Master/Slave RoleSetup Multi-Shelf Configuration Configuring the initial master/slave rolesConfigure the Reference Clock Access and Configuration Configure the Reference ClockConfiguring the reference clock source for the T0/T4 path Upgrading the firmware/software Perform Firmware/Software UpgradeReset the PMC-CGM Access and Configuration Reset the PMC-CGMResetting the PMC-CGM via Snmp Configuring event handling parameters Configure Parameters for Event HandlingPMC-CGM Installation and Use 6806800D53C Page CgmInputTable MIB DescriptionCgmControl MIB StructureInstance CgmInputNumber CgmInputName CgmInputFrequency DefaultInput Assignments MIB DescriptioncgmControlCgmControl MIB Description CgmBitsTableNot yet supported CgmControlMIB Description Is present. This should only be set for test purposes CgmControl Elements Input When in nonrevertive operation 1, a selectedMIB Description CgmControl Not supported on PMC-CGM CgmSysCgmEventTable CgmSys MIB DescriptionCode Severity Description Event Codes and SeverityMIB DescriptioncgmSys CgmSysMIB Description CgmSys Objects New firmware image MIB Description CgmClkDist CgmClkDistNot applicable for PMC-CGM CgmClkDist ObjectsCgmClkDist MIB Description PLL Document Title Publication Number Emerson Network Power Embedded Computing DocumentsRelated Specifications Related DocumentationPage Index Sonet