Emerson PMC-CGM manual Environmental Requirements, DC Module Power Requirements, Feature Value

Page 27

RequirementsHardware Preparation and Installation

Table 2-1 Environmental Requirements

Feature

Operating

Non-Operating (packed state)

 

 

 

Temperature

+5ºC (+41°F) to +40ºC (+104°F)

-40ºC (-40°F) to +85ºC (+185°F)

 

(normal operation) according to NEBS

 

 

Standard GR-63-CORE

 

 

-5°C (+23°F) to +55°C (+131°F)

 

 

(exceptional operation) according to

 

 

NEBS Standard GR-63-CORE

 

 

 

 

Temp. change

+/- 0.25ºC/min according to NEBS

+/- 0.25ºC/min

 

Standard GR-63-CORE

 

 

 

 

Relative humidity

5% to 90% non-condensing according

5% to 95% non-condensing according to

 

to Emerson-internal environmental

Emerson-internal environmental

 

requirements

requirements

 

 

 

Vibration (tested

0.1 g from 5 to 100 Hz and back to 5 Hz

5-20 Hz at 0.01 g2/Hz

in target platform)

at a rate of 0.1 octave/minute.

20-200 Hz at -3.0 dB/octave

 

 

 

 

Random 5-20 Hz at 1 m2/Sec3

 

 

Random 20-200 Hz at -3 dB/octave

 

 

 

Shock

Half-sine, 11 mSec, 30 m/Sec2

Blade level packaging

 

 

Half-sine, 6 mSec at 180 m/Sec2

Free fall

-

200 mm/all edges and corners

 

 

1.0 m (packaged) per ETSI 300 019-2-2

 

 

(Blade level packaging)

 

 

100 mm (unpackaged) per GR-63-

 

 

CORE

 

 

 

2.2.2.2Power Requirements

Make sure that the module is only used on an ATCA-F103 blade in an AdvancedTCA shelf connected to -48VDC up to -60VDC (rated voltage), according to Telecommunication Network Voltage (TNV-2).

A TNV-2 circuit is a circuit whose normal operating voltages exceed the limits for a safety-extra- low-voltage (SELV) under normal operating conditions, and which is not subject to overvoltages from telecommunication networks.

Table 2-2 DC Module Power Requirements

Feature

Value

 

 

Rated Voltage

3.3V

 

 

Operating Voltage

3.3V +/-3%

 

 

Input current

1.5A

 

 

PMC-CGM power dissipation

5W (max.)

 

 

PMC-CGM Installation and Use (6806800D53C)

27

Image 27
Contents PMC-CGM Contact Address Contents Contents List of Tables List of Tables PMC-CGM Installation and Use 6806800D53C Location of PMC Slot on ATCA-F103 List of FiguresList of Figures PMC-CGM Installation and Use 6806800D53C Overview of Contents About this ManualAbbreviations RTM About this Manual Abbreviation DefinitionConventions Notation DescriptionBold Part Number Publication Date Description Summary of ChangesComments and Suggestions About this Manual Notation DescriptionElectrical Interference Safety NotesInstallation Safety NotesOperation Configuration Switches Cabling and ConnectorsEnvironment Safety Notes PMC-CGM Installation and Use 6806800D53C EMV SicherheitshinweiseSicherheitshinweise Schaltereinstellungen Kabel und SteckerUmweltschutz Sicherheitshinweise PMC-CGM Installation and Use 6806800D53C Introduction FeaturesStandard Description Standard CompliancesStandard Compliances and Clocking Standards Introduction Standard CompliancesOrder Number Description Ordering InformationAvailable Board Variants Ordering InformationIntroductionPage Unpacking and Inspecting the Module Hardware Preparation and InstallationBefore Installation OverviewRequirements Hardware Preparation and Installation RequirementsFeature Value DC Module Power RequirementsRequirementsHardware Preparation and Installation Feature Operating Non-Operating packed stateSwitch Location Configuring the ModuleInstalling and Removing the Module Switch SettingsSwitch Hardware Upgrades and Acessories Installation ProcedureRemoval Procedure Controls, LEDs and Connectors Front Panel Connectors and LEDsLayout Controls, LEDs and Connectors Bits Interface Connectors Bits Interface ConnectorsLEDs LEDs Controls, LEDs and ConnectorsName Description LED DescriptionAccessing the PMC-CGM Access and ConfigurationAccess Access and Configuration CablingCabling Using a MIB Browser Access and Configuration Using a MIB BrowserConfiguring the PMC-CGM MIB Browser SettingsDefining Snmp Trap Destinations Define IP Address of the Protection Partner ModuleDefine Snmp Trap Destinations Defining the IP address of the protection partner moduleConfiguring the Bits interface Configure the Interface ModeConfigure the Bits Interface Configuring the interface modeSetting up a multi-shelf configuration Configure Initial Master/Slave RoleSetup Multi-Shelf Configuration Configuring the initial master/slave rolesConfigure the Reference Clock Configuring the reference clock source for the T0/T4 pathConfigure the Reference Clock Access and Configuration Upgrading the firmware/software Perform Firmware/Software UpgradeReset the PMC-CGM Resetting the PMC-CGM via SnmpReset the PMC-CGM Access and Configuration Configuring event handling parameters Configure Parameters for Event HandlingPMC-CGM Installation and Use 6806800D53C Page CgmInputTable MIB DescriptionCgmControl MIB StructureInstance CgmInputNumber CgmInputName CgmInputFrequency DefaultInput Assignments MIB DescriptioncgmControlCgmControl MIB Description CgmBitsTableNot yet supported CgmControlMIB Description Is present. This should only be set for test purposes CgmControl Elements Input When in nonrevertive operation 1, a selectedMIB Description CgmControl Not supported on PMC-CGM CgmSysCgmEventTable CgmSys MIB DescriptionEvent Codes and Severity MIB DescriptioncgmSysCode Severity Description CgmSysMIB Description CgmSys Objects New firmware image MIB Description CgmClkDist CgmClkDistCgmClkDist Objects CgmClkDist MIB DescriptionNot applicable for PMC-CGM PLL Document Title Publication Number Emerson Network Power Embedded Computing DocumentsRelated Specifications Related DocumentationPage Index Sonet