Fujitsu 4Gbit/s FC I/O Modules manual For ETERNUS4000 model 300/500 and ETERNUS8000 Specify

Page 32

For ETERNUS4000 model 300/500 and ETERNUS8000

Specify "255".

7Double-click "QueueTarget" in "Adapter Parameters".

8Set "1" (fixed value) in "Value" in "Modify Adapter Parameter", and click [Apply].

9Click "LinkSpeed" in "Adapter Parameters".

10Select the value from the list box to "Value" in "Modify Adapter Parameter", and click [Apply].

For the setting values, refer to the ETERNUS Server Connection Guide, etc.

Setting value "1": Select "1Gb"

Setting value "2": Select "2Gb"

Setting value "4": Select "4Gb"

No setting is necessary: Select "Auto-select" (Default)

When there are two or more adapters, and the setting for each adapter will be changed separately, perform the procedures from Step 2 to 10 for each adapter.

11Check the parameters that have been set.

The set values are displayed in "Value".

If the parameter is displayed in red, the setting is not applied. Click [Apply].

When Topology: 0, QueueDepth: 8, QueueTarget: 1 for all the adapters

12When the settings for all the adapter finishes, select "Exit" from "File" menu, and exit HBAnyware Utility.

After exiting HBAnyware Utility, perform "5.2 Registry Setting" (￿pg.71).

70

Image 32
Contents Before Reading This Manual Key Descriptions / Operations SymbolsEntering Commands Keys Abbreviations Handling this productChecking the Items Supplied Contents Page 4Gbit/s FC I/O Module OverviewSpecifications How to Check the Driver Version Points to Note When Using This Driver 4Gbit/s FC I/O Module to Eternus ConnectionsFabric connection Event logInstalling the 4Gbit/s FC I/O Module Installing in a Server BladeInstallation Position of the 4Gbit/s FC I/O Module Remove the top coverInstall the 4Gbit/s FC I/O Module Install the server blade in the chassisSecure the 4Gbit/s FC I/O Module with the screws Attach the top coverConnecting Cables This chapter explains points to note when connecting cablesInstalling Drivers and Utilities Automatic InstallationClick Finish Select Emulex PLUS, and click Next Click Next Click Finish Manual InstallationInstalling Emulex Plus Installing *****port Miniport Driver Click the Driver tab and click Update DriverCheck the driver version Close the board property windowCheck the Revision value in Functional Firmware is Checking and Updating Firmware / BootBIOSClick Download Click the Download button Using HBAnyware Utility Click Update Firmware... in FirmwareClick the Update Firmware... in Firmware Uninstalling HBAnywareUninstalling AutoPilot Installer 4Gbit/s FC I/O Module Details Setting 4Gbit/s FC I/O Module Setting Double-click QueueDepth in Parameters FC-ALSet a value in New Value, check Permanent, and click Change Check the parameters that have been set 4Gbit/s FC I/O Module Details Setting Select the local server, and click the Driver Parameters tab Connection type Value For ETERNUS4000 model 300/500 and ETERNUS8000 Specify Follow the paths below Registry SettingAfter finishing all the settings, restart the server blade Checking the Link Status TroubleshootingHow to start the Light Pulse Bios Utility Troubleshooting Correctly? Guide provided with the serverAppendix a How to Identify the Adapter This chapter explains how to identify the adapterAppendix B Contact Information Page Issued on 発行責任