Fujitsu 4Gbit/s FC I/O Modules 4Gbit/s FC I/O Module to Eternus Connections, Fabric connection

Page 10

1.44Gbit/s FC I/O Module to ETERNUS Connections

This section explains the connection of the 4Gbit/s FC I/O Module and ETERNUS.

Fabric connection

Connect to the ETERNUS via FC Switch Blade.

BX600 S3 chassis

 

 

 

 

PRIMERGY BX620 S3/BX620 S4

 

FC Switch Blade (PG-FCS103)

 

 

 

 

 

 

PG-FCD201

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FC Switch Blade (PG-FCS103)

 

 

 

 

 

 

 

 

 

 

 

 

 

ETERNUS3000/

ETERNUS6000

1.5Notes on Replacing the 4Gbit/s FC I/O Module

When an operating 4Gbit/s FC I/O Module has been replaced with a new 4Gbit/s FC I/O Module, it may be necessary to change the storage and FC Switch Blade settings because the WWN of the 4Gbit/s FC I/O Module will change.

1.6Points to Note When Using This Driver

Event log

When the system is started using this driver, the following logs are stored in the event viewer system log. They can be ignored.

5QWTEGGNZRNWU 'XGPV+& 6[RG+PHQTOCVKQP &GUETKRVKQP

6JGFGUETKRVKQPHQT'XGPV+&=?KP5QWTEG=GNZRNWU?ECPPQVDGHQWPF 6JGNQECNEQORWVGTOC[PQVJCXGVJGPGEGUUCT[TGIKUVT[KPHQTOCVKQPQT OGUUCIG&..HKNGUVQFKURNC[OGUUCIGUHTQOCTGOQVGEQORWVGT;QWOC[ DGCDNGVQWUGVJG#7:5174%'HNCIVQTGVTKXGVJKUFGUETKRVKQPUGG *GNRCPF5WRRQTVHQTFGVCKNU6JGHQNNQYKPIKPHQTOCVKQPKURCTVQHVJGGXGPV 

48

Image 10
Contents Before Reading This Manual Entering Commands Keys SymbolsKey Descriptions / Operations Abbreviations Handling this productChecking the Items Supplied Contents Page 4Gbit/s FC I/O Module OverviewSpecifications How to Check the Driver Version Fabric connection Points to Note When Using This Driver4Gbit/s FC I/O Module to Eternus Connections Event logInstalling the 4Gbit/s FC I/O Module Installing in a Server BladeInstallation Position of the 4Gbit/s FC I/O Module Remove the top coverSecure the 4Gbit/s FC I/O Module with the screws Install the 4Gbit/s FC I/O ModuleInstall the server blade in the chassis Attach the top coverConnecting Cables This chapter explains points to note when connecting cablesInstalling Drivers and Utilities Automatic InstallationClick Finish Installing Emulex Plus Manual InstallationSelect Emulex PLUS, and click Next Click Next Click Finish Installing *****port Miniport Driver Click the Driver tab and click Update DriverCheck the driver version Close the board property windowClick Download Checking and Updating Firmware / BootBIOSCheck the Revision value in Functional Firmware is Click the Download button Using HBAnyware Utility Click Update Firmware... in FirmwareUninstalling AutoPilot Installer Uninstalling HBAnywareClick the Update Firmware... in Firmware 4Gbit/s FC I/O Module Details Setting 4Gbit/s FC I/O Module Setting Double-click QueueDepth in Parameters FC-ALSet a value in New Value, check Permanent, and click Change Check the parameters that have been set 4Gbit/s FC I/O Module Details Setting Select the local server, and click the Driver Parameters tab Connection type Value For ETERNUS4000 model 300/500 and ETERNUS8000 Specify After finishing all the settings, restart the server blade Registry SettingFollow the paths below How to start the Light Pulse Bios Utility TroubleshootingChecking the Link Status Troubleshooting Correctly? Guide provided with the serverAppendix a How to Identify the Adapter This chapter explains how to identify the adapterAppendix B Contact Information Page Issued on 発行責任