Fujitsu 4Gbit/s FC I/O Modules manual 4Gbit/s FC I/O Module Setting

Page 25

5.14Gbit/s FC I/O Module Setting

There are two methods for this product setting. The results will bring no difference. ￿"5.1.1 Using LightPulse Utility / NT"(pg.63)

￿"5.1.2 Using HBAnyware Utility"(pg.68)

5.1.1Using LightPulse Utility / NT

This product name displayed in LightPulse Utility/NT is "Adapter * -BX600FC42E -* Port *".

To identify the 4Gbit/s FC I/O Module from LightPulse Utility/NT in an environment where multiple 4Gbit/s FC I/O Module are installed, refer to "Appendix A How to Identify the Adapter" (￿pg.74).

1Click the "Start" button "Programs" or "All Programs" "Emulex" "lpUtilNT" in this order.

￿When adding this product after installation, the settings for the existing product may be changed. Therefore, after adding this product or driver, check the detailed settings and correct them if necessary.

2Select "Driver Parameters" in the "Category" field.

3Select "Parameters".

The following parameter data are displayed.

For PG-FCD201, Adapter 0 and 1are displayed.

E

 

5 4Gbit/s FC I/O Module Details Setting 63

Image 25
Contents Before Reading This Manual Entering Commands Keys SymbolsKey Descriptions / Operations Handling this product AbbreviationsChecking the Items Supplied Contents Page Overview 4Gbit/s FC I/O ModuleSpecifications How to Check the Driver Version 4Gbit/s FC I/O Module to Eternus Connections Points to Note When Using This DriverFabric connection Event logInstalling in a Server Blade Installing the 4Gbit/s FC I/O ModuleRemove the top cover Installation Position of the 4Gbit/s FC I/O ModuleInstall the server blade in the chassis Install the 4Gbit/s FC I/O ModuleSecure the 4Gbit/s FC I/O Module with the screws Attach the top coverThis chapter explains points to note when connecting cables Connecting CablesAutomatic Installation Installing Drivers and UtilitiesClick Finish Installing Emulex Plus Manual InstallationSelect Emulex PLUS, and click Next Click Next Click Finish Click the Driver tab and click Update Driver Installing *****port Miniport DriverClose the board property window Check the driver versionClick Download Checking and Updating Firmware / BootBIOSCheck the Revision value in Functional Firmware is Click the Download button Click Update Firmware... in Firmware Using HBAnyware UtilityUninstalling AutoPilot Installer Uninstalling HBAnywareClick the Update Firmware... in Firmware 4Gbit/s FC I/O Module Details Setting 4Gbit/s FC I/O Module Setting FC-AL Double-click QueueDepth in ParametersSet a value in New Value, check Permanent, and click Change Check the parameters that have been set 4Gbit/s FC I/O Module Details Setting Select the local server, and click the Driver Parameters tab Connection type Value For ETERNUS4000 model 300/500 and ETERNUS8000 Specify After finishing all the settings, restart the server blade Registry SettingFollow the paths below How to start the Light Pulse Bios Utility TroubleshootingChecking the Link Status Correctly? Guide provided with the server TroubleshootingThis chapter explains how to identify the adapter Appendix a How to Identify the AdapterAppendix B Contact Information Page 発行責任 Issued on