Extron electronic PVS 305SA manual Testing and Adjustment Procedure, Sensitivity knob adjustment

Page 41

5. Close and latch the top of the Priority Page Sensor. Reconnect the speaker cable to the speaker.

6. Strip 3/16 inches of insulation from each conductor on the

bare wire end of the remaining blue sensor cable. Do not tin the leads. Feed the wire into the junction box (clamping it down if necessary) and connect the wires to the 2-pole captive

screw connector on the PVS 305SA. Polarity need not be

observed.

7. If a junction box is being used in a plenum space, ensure the sensor and all wires fit inside the box (as shown at right). All cables leaving the box must be plenum rated. Tighten the cable clamp and secure the lid to the junction box.

NTo enable the switcher’s paging sensor port, use the MediaLink Switchers Configuration program (for MLS and PoleVault Switchers PVS), available at www.extron.com.

Testing and Adjustment Procedure

The fully installed system is shown below To test that the classroom audio is muted when a PA system announcement (page) occurs:

1. Turn the classroom audio on.

2. Speak into the PA system microphone. The classroom audio should be muted while the PA system page occurs and be restored when the page ends.

3. If the program fails to mute the classroom audio during a page, turn the Sensitivity adjustment, on the front panel of the PVS 305SA, clockwise.

4. If the classroom audio is muted without a page occurring, turn the Sensitivity adjustment counterclockwise

Admin Building

Classroom

 

To Classroom

 

Ceiling Mounted

 

Paging Speakers

 

Paging Speaker

 

 

Priority

 

FF 120

 

Page

 

Flat Field

 

Sensor

Sensor

Speakers

 

 

Output

 

Paging

Sensor

Input

PVS 305SA

PoleVault Switcher

Paging System

Typical paging system with the PVS 305SA switcher

 

 

LINE OUT

 

 

 

 

 

 

AMPLIFIED AUDIO OUT

 

 

 

 

 

 

 

 

 

O O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GROUND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OR SHORT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2/4/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPEAKER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLASS 2 WIRING

 

 

 

 

 

L

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

L

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL

 

 

 

 

 

 

 

 

10V

 

 

 

 

50mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tx

 

Rx

 

IR

 

12V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUX AUDIO

 

 

 

 

PAGING

 

 

 

 

 

 

 

 

RS-232 MLC/IR

 

 

 

 

 

 

 

 

 

INPUT 5

 

 

 

 

 

 

SENSOR VOL/

MUTE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PVS 305SA

Page

Sensor

6Connect the Priority Page Sensor to the Paging Sensor port on the switcher

7Ensure the sensor and wires fit completely inside the junction box before attaching the cover

PVS 305SA

 

 

 

 

 

 

 

 

 

SWITCHER

 

 

 

 

 

 

 

POLEVAUL

 

AUDIO LEVEL ADJUST

PAGING

 

 

 

 

 

 

 

 

 

 

 

 

 

PEAK

 

 

 

MIC

 

 

PEAK

 

 

 

SENSOR

NORMAL

NORMAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIGNAL

VOICELIFT

SIGNAL

SENSITIVITY

 

 

 

 

 

 

 

 

 

Adjusting sensitivity knob:

Clockwise to increase

Counterclockwise to decrease

3 and 4 Sensitivity knob adjustment

PoleVault Systems Installation • Optional Accessory Installation

3-3

Image 41
Contents PoleVault Systems Installation GuideSafety Instructions English PrecautionsConsignes de Sécurité Français Sicherheitsanleitungen DeutschFCC Class B Notice PoleVault Systems Installation IntroductionIntroduction Introduction, contd PoleVault System installation and wiring overviewPoleVault Systems Installation Introduction Planning Typical classroom installationRoom layout RoomIntroduction Planning, cont’d Example classroom installationLocation of the screen and projector ADA overhead and side clearance requirementsLocation of MediaLink Controller and Wall Plates Example classroom with four speaker installationLocation of source devices Cabling obstaclesIncluded items Introduction Inventory OverviewInventory PoleVault System Devices and Hardware, cont’d Items not included Optional installation hardwareIntroduction Inventory Overview, cont’d Installation tools PoleVault Systems Installation Installation Installation OverviewOutline of installation steps PoleVault Systems Installation Installation Stage Stage One Install the Screen and ProjectorPCM 340 Projector Drop Ceiling Mount Slotted Pipe Supplied with PCMInstall projector to verify location Installation Stage One, cont’dMark screen location 1a Mark the screen locationVerify the image location 2f Slide and lock the projector onto the adjuster plate2e Attach the bracket to the projector Horizontal offset5a Mark structural ceiling for lag eye bolt installation Preliminary safety hardware installationCut the ceiling tile 4b Take measurements with the PCM 340 on the T-frameSecure the Projector Drop Ceiling Mount to the ceiling Finish Projector Drop Ceiling Mount installation7a Attach turnbuckles at the corners 7c Hand tighten the turnbuckles8a Install Raco box and plaster ring Install the electrical box if requiredInstall the Screen MLC 104 IP Plus MediaLink Controller Stage Two Install the Wall Plates and MLC 104 IP PlusThis stage involves installing the devices shown below Cables Installation Stage Two, cont’dIR/RS-232 communications cable control cable RS-232 or to an IR emitter1d Features for mud ring installation Install the mud ringsMLC 104 IP Plus mud ring 1c Insert the mud ring2c Pull the cables at each location Signal Cable Label colorPull the cables at the input locations MLC 104 IP Plus controller Install wall plates4a Connecting the MLC to the switcher Install MediaLink ControllerWire stripping lengths Connect the MLC to the projector with 4c Connect to the LAN using a CAT 5 cableAn RS-232 cable or IR emitter cable, as Appropriate4e Secure the MLC 104 IP Plus to the mud ring Connections made to the MLC 104 IP PlusFF 120 Flat Field Ceiling Speakers Stage Three Install the FF 120 Ceiling SpeakersInstall the speaker on the drop ceiling Installation Stage Three, cont’d2h Attach safety cable Cut ceiling tilePole captive screw connector Terminate the speaker cable for the PVS switcherStereo or dual mono output using parallel speaker wiring To terminate the cable, strip the end of the cable 0.2 inchThis stage covers installing the devices shown below Stage Four Install the PMK 550 and the PVS 305SAPVS 305SA PoleVault Switcher PMK 550 Pole Mount KitPoleVault Systems Installation Installation Stage 4 Install the PMK 550 base platePull the cables at the switcher location Installation Stage Four, cont’dSwitcher and projector cable overview 2b Gather the cables, pass them down the pipeBControl/power cable from the MLC 104 IP Plus Finish installing the Pole Mount kit4a Connect the cables to the switcher Connect the cables as follows to the PVS 305SA4d Cable the projector 4b Reattach UPB bracket and 4c projectorGlobal configurator software Stage Five Configure the Switcher and the SystemConfigure the switcher MLS Switcher Configuration program Configure the system Global Configurator Installation Stage Five, cont’dTest the system Loosen all pivot screws and adjust the vertical angle3c Check that an image is present, adjust as needed Adjust the configuration as necessary Final installationWhere installed, if necessary, adjust the sensitivity 3d Test the MLC configurationAlign the arrows on the housing rim and the dome tab Optional Accessory Installation VoiceLift SystemAttach the Z bracket to the ceiling tile and the back plate Plug VoiceLift cable into PVS 305SAOpen the sensor and loop a wire around the sensor Optional Accessory Installation Priority Page Sensor KitPriority Page Sensor Kit included parts UL-compliant junction box and cover4 Sensitivity knob adjustment Testing and Adjustment ProcedureTypical paging system with the PVS 305SA switcher Reference Information PoleVault Systems Installation Reference InformationLbs 0.1 kg Wall or furniture mountable with included Decora wall plateExtron PCM Reference Information, cont’dPVS 305SA specific symbol definitions SIS CommandsSIS Command/Response Table Ascii Telnet PoleVault Systems Installation Basic SIS CommandsExtron USA West