<P=004>
OPTIONAL SETTINGS
Setting 16: CASSETTE SELECTION
Press "1" if you want the fax to automatically select the source from which it draws paper for printing according to the size of the document received or copied. Press "2" if you want to give priority to the paper cassette (paper will be drawn from the cassette regardless of the size of the received document), or press "3" if you want to give priority to the paper tray.
∙Factory setting: "1"
Setting 17: CASSETTE CHANGEOVER
Press "1" to have the fax start drawing paper from the other paper source if the currently used source runs out of paper. Press "2" to stop changeover to the other source (in this case, received documents will be stored in memory).
∙Factory setting: "1"
Setting 18: RETRANSMISSION TIMES
This sets the number of times the fax will reattempt a memory transmission which has been interrupted by a line error or power failure. Enter any number from "00" to "14" ("00" disables the function).
∙Factory setting: "10"
Setting 19: RETRANSMISSION INTERVAL
If desired, you can have the fax wait a certain number of minutes between each memory retransmission attempt. Enter "01" for 1 minute, "02" for 2 minutes, etc., up to a maximum of 15 minutes. If you do not want the fax to wait between attempts, enter "00".
∙Factory setting: "00"
Setting 20: HEATER MODE
To conserve electricity, you can turn off the laser printer heater in your fax. When this is done, it will turn on automatically when you receive a document (there will be a slight delay before printing while it warms up) and turn off once printing is completed. You can also set the heater to automatically turn on and off at two selected times each day. Enter a number from "1" to "3" as follows:
"1" (ALWAYS ON): | The heater will remain on constantly. |
"2" (ALWAYS OFF): | The heater will turn on only to print documents. |
"3" (SLEEP MODE TIMER): The heater will turn on and off at two selected times each day. After you press "3", enter the time you want the heater to turn on, and then the time you want it to turn off. For each time, enter 2 digits for the hour, 2 digits for the minute, and then "*" for A.M., or "#" for P.M.
∙Factory setting: "2"
OPTION SETTINGS |