GE 300, 225 manual Table of contents

Page 5

g

Table of contents

GE

Page

1

IMPORTANT SAFETY INSTRUCTIONS

6

2

LAYOUT

9

2.1

 

LAYOUT SG SERIES 225 AND 300 KVA

9

3

INSTALLATION

10

3.1

 

TRANSPORT

10

 

3.1.1

Dimensions and weight

10

3.2

 

DELIVERY

11

3.3

 

STORAGE

11

 

3.3.1 Storage of the UPS

11

 

3.3.2

Storage of Battery

11

3.4

 

PLACE OF INSTALLATION

12

 

3.4.1

UPS location

12

 

3.4.2

Battery location

14

3.5

 

VENTILATION AND COOLING

15

3.6

 

UNPACKING

16

3.7

 

ELECTRICAL WIRING

17

 

3.7.1

Utility input connection

17

 

3.7.2 Input/output over current protection and wire sizing

18

 

3.7.3 Battery over current protection and wire sizing

19

3.8

 

WIRING CONNECTION

21

 

3.8.1

Power connections

21

 

3.8.2 Power connection with common input utility

23

 

3.8.3 Power connection separate input utility

25

 

3.8.4

Battery connection

27

 

3.8.5 Setup for SG Series when functioning as frequency converter

28

3.9

 

POWER WIRING OF PARALLEL UNITS

29

3.10

 

PARALLEL CONTROL BUS CONNECTION

30

3.11

 

CONTROL BUS CABLE LOCATION

32

4

CUSTOMER INTERFACE

34

4.1

 

CUSTOMER INTERFACE

34

 

4.1.1

Serial Port J3

35

 

4.1.2 Output potential free contacts

35

 

4.1.3 Programmable input free contacts

36

 

4.1.4 Gen Set Signaling (GEN ON)

36

 

4.1.5 AUX external Maintenance Bypass

36

 

4.1.6 Auxiliary Power Supply (APS) 24 VDC / 1A

36

 

4.1.7 EPO (Emergency Power Off) Input contact

37

5

NOTES

38

5.1

 

NOTES FORM

38

OPM_SGS_ISG_M22_M30_0US_V011.doc

5/38

Installation Guide SG Series 225 & 300 kVA

Image 5
Contents SG Series Systems Copyright 2003 by GE Industrial SystemsStart UP and Commissioning Dear CustomerPreface Table of contents Battery InstallationGeneral StorageSafety instructions when working with battery Safety warnings Safety symbols and warningsRisk of electric shock PE Earth GND Ground Protective Grounding TerminalLayout SG Series 225 and 300 KVA LayoutWeight SG Series 225 and 300 kVA Dimensions and weightTransport Forklift Crane Transport UPS only in upright positionStorage of the UPS Storage of BatteryDelivery Check -26A of the NEC code for specific requirements Place of InstallationPositioning of the UPS SG Series Fixing of the UPS cabinet on the floor Openings for input and output cable connections1-5 RPA system disposition Battery locationCFM Ventilation and CoolingPacking material recycling Take care not to damage the UPS when moving by forkliftUnpacking Common input Rectifier & Bypass Electrical WiringSeparate input Rectifier & Bypass recommended Neutral current could be greater than the phase currents Input/output over current protection and wire sizingPhase, 4 wire plus Ground Phase, 3 wire plus GroundWire positive and negative plus Ground See .7.1-1Copper Wire Size Range Wiring Connection1-1 Access to the input / output connections Output Load Power connection with common input utilityCommon Input Rectifier / Bypass Cable section for this connection shall be not less then AWG L1-1 Rectifier Phase a L1-2 Power connection separate input utilityL2-1 Rectifier Phase B L2-2 L3-1 Rectifier Phase C L3-2BR1 Battery Battery connectionPositive pole of the Battery Do not insert the Battery Fuses before the commissioningManual Bypass, serious damage to the Load could result Setup for SG Series when functioning as frequency converter1 RPA Parallel System Power Wiring of Parallel UnitsParallel Control BUS Connection UPSIntermediate units Terminal unitsControl BUS Cable Location Access to the control bus connectionControl bus cables connection Interface IM0048 going to P1311-3 Control Bus cable routing and connection Control bus cables routingCustomer Interface Customer Interface18, 19 Or J2 20, 21 NO, C, NC Acoustic Alarm 15, 16 Or J2 17, 18 NO, C, NC General AlarmOutput potential free contacts Or J2 / 1, 2 NO, C, NC Utility FailureGND JP3 EPO Emergency Power Off Input contact38/38