You will need the following components to install the RPSD Lock:
■RPSD Lock device
■the CO line assigned as the RMATS channel (on customer premises)
■the PBX modem (on customer premises)
■6 position wire (length depends on local configuration)
■two modular connectors
■two DB25 connectors (male)
■
■administration terminal
■AC outlet
■RPSD Lock power pack
Connecting the RPSD Lock to the CO Line
The following components are needed to connect the RPSD Lock device to the CO line:
■RPSD Lock
■the CO line assigned as the RMATS channel
■two modular connectors
■6 position wire
■RJ11 connector (for the CO line)
To connect the RPSD Lock device to the CO line, use the following procedure:
1The customer must contact the technical support center to get the port number for the RMATS channel.
2Locate the CO line for the RMATS port where it connects to the modem.
3Install an RJ11 receptacle on the CO line.
4Connect a wired modular connector to the CO line.
5Plug the modular connector on the other end of the wire into the Telco port on the back of the RPSD Lock.
Note: Bypass connectors are optional. See Figure