C - Clock Set
Syntax:
c <hh:mm> [ RETURN ]
Set the clock to local time standards in 24 hour clock format (for example, 16:00 for 4:00 PM). The clock must be set in order to ensure the accuracy of the System Activity Log and also because the clock is used by the RPSD Lock for enabling and disabling time restrictions.
Be certain to use a colon (:) to separate the hours and minutes. Also be certain to use a leading zero if setting the time less than 10:00.
Sample Command and Response:
> c 13:15
JPLock01 199 08/17/90 15:15:00 Time Changed OK
I - ID Set
Syntax:
i <log_id> [ RETURN ]
The ID set command is used to set a unique identifier for the RPSD Lock. It is useful in the event that more than one RPSD Lock is in operation. The Lock’s ID is added to the beginning of all message output so that the administrator can identify the Lock concerned.
In the syntax above, i is the command and <log_id> is the name selected by the system administrator to identify the Lock.
To clear the ID, enter i
The Log ID is limited to 8 alpha/numeric characters.
Sample Command and Response:
> i JPLock02
JPLock02 004 08/17/90 15:42:21 Log ID Changed OK
>
Note that in the sample the ID is appended to the beginning of the status message. This is where it will appear on all status messages once the ID is set.