Test RPSD Lock Installation
The Self Check tests the health of the RPSD Lock. If the correct response is received when the test is run, the RPSD Lock is functioning properly.
To perform the Self Check, dial the RMATS channel from a
If the response is 3 quick tones, followed by the RPSD Lock disconnecting, the Lock is functioning properly.
Finally, have the technical support center call the RMATS channel. If access is successful, the installation is working properly. If access is unsuccessful, refer to Chapter 5, Troubleshooting.
After a successful access of the port has shown the Lock to be working properly, try dialing out through the RMATS channel via the Lock. If you have trouble with making an outgoing call, the likeliest scenario is that the tip and ring leads are reversed. Reverse the current connection of the tip and ring leads from the CO line to the RPSD Lock and try dialing out again. A failure at this juncture indicates something is wrong with the Lock. See Chapter 5, Troubleshooting. If the Lock does not work properly, it must be replaced.
If all tests are passed successfully, installation is complete for the technician. Lock initialization can now be performed by the RPSD system administrator.
Test RPSD Lock Installation |