Maxon Telecom MM-6280IND manual DTE-TA/DCE interface commands, MT2 TE2, TE2 MT2

Page 12

The following diagram shows the naming convention of messages between MT2 and TE2.

TE2

Command (including AT)

Response (excluding AT)

MT2

TE2

Notification (excluding AT)

MT2

<TE2 sends command to MT2>

<MT2 sends notification message to TE2>

 

 

 

Signal (H/W)

 

 

 

TE2

MT2

 

 

Indication (message)

<MT2 sends H/W signalling to TE2>

Figure 1. Naming convention diagram

1.8.DTE-TA/DCE interface commands

Table 3. ITU-T V.250 commands relating to TE-TA interface

 

Command

 

 

Req

 

 

Description

 

 

Support

 

E<value>

 

 

Mand.

 

Command echo

 

 

supported

 

 

 

 

 

 

 

 

 

 

 

 

Q<value>

 

Mand.

 

Result code suppression

 

 

supported

 

 

 

 

 

 

 

 

 

 

 

 

S3

 

 

Mand.

 

Command line termination character

 

 

supported

 

S4

 

 

Mand.

 

Response formatting character

 

 

supported

 

 

 

 

 

 

 

 

 

 

 

 

S5

 

 

Mand.

 

Command line editing character

 

 

supported

 

 

 

 

 

 

 

 

 

 

 

 

V<value>

 

Mand.

DCE response format

 

 

supported

 

 

 

 

 

 

 

 

 

 

 

 

X<value>

 

 

Mand.

 

Result code selection and call progress monitoring control

 

supported

 

 

 

 

 

 

 

 

 

 

 

 

&C<value>

 

Mand.

Circuit 109 DCE RLSD (DCD) behavior

 

 

supported

 

 

 

 

 

 

 

 

 

 

 

 

&D<value>

 

Mand.

Circuit 108 DTE DTR behavior

 

 

supported

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fixed Rm Rate. This numeric extended-format parameter

 

supported

 

 

 

 

 

 

specifies the data rate at which the MT2 will accept

 

 

 

 

 

 

 

 

command set, in addition to 1200 bit/s or 9600 bit/s (as

 

 

 

 

 

 

 

 

required in EIA/TIA-602). It may be used to select operation

 

 

 

+IPR=<rate>

 

 

Opt.

 

at rates at which the MT2 is not capable of automatically

 

 

 

 

 

 

detecting the data rate being used by the TE2.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115200bps. (Default)

 

 

 

 

 

 

 

 

 

+IPR? Displays current set value.

 

 

 

 

 

 

 

 

 

+IPR=? Displays range of (supported auto detectable rates),

 

 

 

 

 

 

 

 

(list of supported fixed-only rates). e.g. +IPR: (1200, 2400,

 

 

 

HSDPA Standard At Commands

Page 12 of 60

Version 1.2

 

Image 12
Contents Hsdpa Standard AT Commands Manual Document Description Revision History Contact Information Table of Contents Qualcomm commands Introduction GeneralTerms Terms definitionReferences 3GPP TSGSM MoU SE.13 ITU-T Recommendation E.212ITU-T Recommendation T.31 ITU-T Recommendation T.32Ccitt Recommendation ITU-T RecommendationEtsi TS 102 RFC 3748, JuneCommand Format AT command FormatBasic Integration Serial InterfaceDTE-TA/DCE interface commands MT2 TE2TE2 MT2 +ICF TE2-MT2+IFC +ILRR Mobile Termination errors commands Report Mobile Termination error +CMEEMobile Termination error result code CME Error +CMEE parameter command syntaxHsdpa Standard At Commands AT+CGMI Error AT+CMEE=1 AT+CGMI +CME Error AT+CMEE=2Informative examples AT+CMEE=0General commands Request manufacturer identification+CGMIRequest model identification+CGMM +CGMM action command syntax +CGSN action command syntax+CSCS parameter command syntax Request product serial number identification +CGSNITU-T V.250 generic TA control commands Pcca STD‑101 17 select wireless network +WS46 Supported alphabets Network service commands +CNUM action command syntax Subscriber number +CNUMNetwork registration +CREG +CNUM+CREG parameter command syntax Plmn selection +COPS+CREG? +CREG=?Applicable in read command response When mode=2 and command successful Facility lock +CLCKUnlock Lock Query status Change password +CPWD +CPWD action command syntaxPreferred Plmn list +CPOL +COLP parameter command syntax +COPN action command syntaxRead operator names +COPN Operator information readingImsi number reading Gprs AttachmentNetwork registration Own number readingMobile Termination control and status commands Basic TEBasic TE Signal quality +CSQ +CSQ action command syntax+CCLK parameter command syntax Clock +CCLKAT$$MBAND Read Command AT$$MBAND Write Command+CPIN parameter command syntax Band Selection AT$$MBANDSignal strength reading PH-SIM PINPin registration Packet Domain CommandGPRS Umts packet Domain commandsUmts packet Domain commands Command Req Description Support +CGDCONT parameter command syntax Define PDP Context +CGDCONT+CGDCONT? +CGDCONT=?Define Secondary PDP Context +CGDSCONT PPPError Traffic Flow Template +CGTFT+CGDSCONT? + Cgtft parameter command syntax +CGTFT? +CGTFT=? Quality of Service Profile Requested +CGQREQ + Cgqreq parameter command syntaxQuality of Service Profile Minimum acceptable +CGQMIN + Cgqmin parameter command syntaxQuality of Service Profile Requested +CGEQREQ + Cgeqreq parameter command syntaxCRLF+CGQMIN SDU+CGEQREQ? +CGEQREQ=?Subscribed value. Other values are reserved Quality of Service Profile Minimum acceptable +CGEQMIN PDPtype see +CGDCONT and +CGDSCONT commands+ Cgeqmin parameter command syntax +CGEQMIN?CRLF+CGEQMIN +CGEQMIN=?Following parameters are defined in 3GPP TS 23.107 Quality of Service Profile Negotiated +CGEQNEG +CGEQNEG action command syntax +CGEQNEG+CGEQNEG=? PS attach or detach +CGATT + Cgatt parameter command syntax + Cgact parameter command syntaxPDP context activate or deactivate +CGACT + Cgcmod parameter command syntax PDP Context Modify +CGCMODEnter data state +CGDATA +CGCMOD=?+ Cgdata parameter command syntax Show PDP address +CGPADDRModem compatibility commands + Cgpaddr parameter command syntaxUmts Connection +CGPADDR=?Synchronous data mode commands Qualcomm commands Qualcomm commandDescription Operation Support $QCPINSTAT $QCPWRDN$QCDGEN= $QCSLOT=
Related manuals
Manual 70 pages 35.54 Kb

MM-6280IND specifications

The Maxon Telecom MM-6280IND is a robust and versatile two-way radio designed to meet the demanding needs of professionals in various fields, including security, construction, and transportation. This model stands out for its combination of advanced features, reliable performance, and user-friendly interface, making it a preferred choice for organizations requiring efficient communication solutions.

One of the key features of the MM-6280IND is its long battery life. Equipped with a high-capacity lithium-ion battery, this radio can provide extended operational time, ensuring that users can stay connected throughout their shifts without frequent recharging interruptions. Additionally, the radio supports multiple battery-saving modes, allowing users to optimize power consumption according to their needs.

The MM-6280IND operates on multiple frequency bands, ensuring compatibility across various communication networks. It supports both analog and digital communication modes, making it adaptable to different environments and user preferences. This dual-mode capability enhances interoperability, allowing seamless communication with other radios, regardless of their technology.

In terms of audio quality, the MM-6280IND features advanced noise-cancellation technology. This ensures clear audio transmission even in noisy environments, such as construction sites or crowded events. Furthermore, the radio is equipped with a built-in speaker and microphone that deliver crisp and loud audio, allowing users to communicate effectively without straining their ears.

Durability is another hallmark of the MM-6280IND. The device is designed to withstand harsh conditions, featuring an IP65 rating for water and dust resistance. This makes it suitable for outdoor use, ensuring that it can function reliably, even in adverse weather conditions. The rugged construction of the radio also protects it from physical impacts, reducing the risk of damage from drops or bumps.

User-friendly functionality is prioritized in the MM-6280IND, with an intuitive keypad and a clear LCD display that make navigation straightforward. It also includes programmable buttons that allow users to customize settings and features according to their specific operational requirements.

Overall, the Maxon Telecom MM-6280IND is a high-performance two-way radio that combines longevity, durability, and adaptability. Its advanced communication technologies and user-focused design make it an excellent tool for professionals seeking efficient and reliable communication solutions in various industries. Whether used for coordinating team efforts or enhancing safety and security, the MM-6280IND is a valuable asset for any organization.