Maxon Telecom MM-6280IND manual PS attach or detach +CGATT

Page 53

Other values are reserved.

<Maximum SDU size>: a numeric parameter that (1,2,3,…) indicates the maximum allowed SDU size in octets (refer TS 24.008 [8] subclause 10.5.6.5).

<SDU error ratio>: a string parameter that indicates the target value for the fraction of SDUs lost or detected as erroneous. SDU error ratio is defined only for conforming traffic. The value is specified as 'mEe'. As an example a target SDU error ratio of 5•10-3would be specified as '5E3' (e.g. +CGEQNEG:…,”5E3”,…) (refer TS 24.008 [8] subclause 10.5.6.5).

<Residual bit error ratio>: a string parameter that indicates the target value for the undetected bit error ratio in the delivered SDUs. If no error detection is requested, Residual bit error ratio indicates the bit error ratio in the delivered SDUs. The value is specified as 'mEe'. As an example a target residual bit error ratio of 5•10-3would be specified as '5E3' (e.g. +CGEQNEG:…,”5E3”,…) (refer TS 24.008 [8] subclause 10.5.6.5).

<Delivery of erroneous SDUs>: a numeric parameter that indicates whether SDUs detected as erroneous shall be delivered or not.

0 - no

1 - yes

2 - no detect

Other values are reserved.

<Transfer delay>: a numeric parameter (0,1,2,…) that indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the other SAP, in milliseconds (refer TS 24.008 [8] subclause 10.5.6.5).

<Traffic handling priority>: a numeric parameter (1,2,3,…) that specifies the relative importance for handling of all SDUs belonging to the UMTS bearer compared to the SDUs of other bearers (refer TS 24.008 [8] subclause 10.5.6.5).

If a value is omitted for a particular class then the value is considered to be unspecified.

1.32.9.PS attach or detach +CGATT

The execution command is used to attach the MT to, or detach the MT from, the Packet Domain service. After the command has completed, the MT remains in V.25ter command state. If the MT is already in the requested state, the command is ignored and the OK response is returned. If the requested state cannot be achieved, an ERROR or +CME ERROR response is returned. Extended error responses are enabled by the +CMEE command.

Any active PDP contexts will be automatically deactivated when the attachment state changes to detached.

The read command returns the current Packet Domain service state.

The test command is used for requesting information on the supported Packet Domain service states.

NOTE: This command has the characteristics of both the V.25ter action and parameter commands. Hence it has the read form in addition to the execution/set and test forms.

HSDPA Standard At Commands

Page 53 of 60

Version 1.2

Image 53
Contents Hsdpa Standard AT Commands Manual Document Description Revision History Contact Information Table of Contents Qualcomm commands General IntroductionTerms Terms definition3GPP TS ReferencesITU-T Recommendation E.212 GSM MoU SE.13ITU-T Recommendation T.31 ITU-T Recommendation T.32ITU-T Recommendation Ccitt RecommendationEtsi TS 102 RFC 3748, JuneAT command Format Command FormatBasic Integration Serial InterfaceTE2 MT2 DTE-TA/DCE interface commandsMT2 TE2 +IFC +ICFTE2-MT2 +ILRR Report Mobile Termination error +CMEE Mobile Termination errors commandsMobile Termination error result code CME Error +CMEE parameter command syntaxHsdpa Standard At Commands AT+CGMI +CME Error AT+CMEE=2 AT+CGMI Error AT+CMEE=1Informative examples AT+CMEE=0Request model identification+CGMM General commandsRequest manufacturer identification+CGMI +CGSN action command syntax +CGMM action command syntax+CSCS parameter command syntax Request product serial number identification +CGSNITU-T V.250 generic TA control commands Pcca STD‑101 17 select wireless network +WS46 Supported alphabets Network service commands Subscriber number +CNUM +CNUM action command syntaxNetwork registration +CREG +CNUMPlmn selection +COPS +CREG parameter command syntax+CREG? +CREG=?Applicable in read command response Facility lock +CLCK When mode=2 and command successfulUnlock Lock Query status Preferred Plmn list +CPOL Change password +CPWD+CPWD action command syntax +COPN action command syntax +COLP parameter command syntaxRead operator names +COPN Operator information readingGprs Attachment Imsi number readingNetwork registration Own number readingBasic TE Mobile Termination control and status commandsBasic TE +CSQ action command syntax Signal quality +CSQ+CCLK parameter command syntax Clock +CCLKAT$$MBAND Write Command AT$$MBAND Read Command+CPIN parameter command syntax Band Selection AT$$MBANDPH-SIM PIN Signal strength readingPin registration Umts packet Domain commands Command Req Description Support Packet Domain CommandGPRSUmts packet Domain commands Define PDP Context +CGDCONT +CGDCONT parameter command syntax+CGDCONT? +CGDCONT=?PPP Define Secondary PDP Context +CGDSCONT+CGDSCONT? ErrorTraffic Flow Template +CGTFT + Cgtft parameter command syntax +CGTFT? +CGTFT=? + Cgqreq parameter command syntax Quality of Service Profile Requested +CGQREQ+ Cgqmin parameter command syntax Quality of Service Profile Minimum acceptable +CGQMIN+ Cgeqreq parameter command syntax Quality of Service Profile Requested +CGEQREQCRLF+CGQMIN SDU+CGEQREQ=? +CGEQREQ?Subscribed value. Other values are reserved PDPtype see +CGDCONT and +CGDSCONT commands Quality of Service Profile Minimum acceptable +CGEQMIN+CGEQMIN? + Cgeqmin parameter command syntaxCRLF+CGEQMIN +CGEQMIN=?Following parameters are defined in 3GPP TS 23.107 Quality of Service Profile Negotiated +CGEQNEG +CGEQNEG=? +CGEQNEG action command syntax+CGEQNEG PS attach or detach +CGATT PDP context activate or deactivate +CGACT + Cgatt parameter command syntax+ Cgact parameter command syntax PDP Context Modify +CGCMOD + Cgcmod parameter command syntaxEnter data state +CGDATA +CGCMOD=?Show PDP address +CGPADDR + Cgdata parameter command syntax+ Cgpaddr parameter command syntax Modem compatibility commandsUmts Connection +CGPADDR=?Synchronous data mode commands Description Operation Support Qualcomm commandsQualcomm command $QCPWRDN $QCPINSTAT$QCDGEN= $QCSLOT=
Related manuals
Manual 70 pages 35.54 Kb

MM-6280IND specifications

The Maxon Telecom MM-6280IND is a robust and versatile two-way radio designed to meet the demanding needs of professionals in various fields, including security, construction, and transportation. This model stands out for its combination of advanced features, reliable performance, and user-friendly interface, making it a preferred choice for organizations requiring efficient communication solutions.

One of the key features of the MM-6280IND is its long battery life. Equipped with a high-capacity lithium-ion battery, this radio can provide extended operational time, ensuring that users can stay connected throughout their shifts without frequent recharging interruptions. Additionally, the radio supports multiple battery-saving modes, allowing users to optimize power consumption according to their needs.

The MM-6280IND operates on multiple frequency bands, ensuring compatibility across various communication networks. It supports both analog and digital communication modes, making it adaptable to different environments and user preferences. This dual-mode capability enhances interoperability, allowing seamless communication with other radios, regardless of their technology.

In terms of audio quality, the MM-6280IND features advanced noise-cancellation technology. This ensures clear audio transmission even in noisy environments, such as construction sites or crowded events. Furthermore, the radio is equipped with a built-in speaker and microphone that deliver crisp and loud audio, allowing users to communicate effectively without straining their ears.

Durability is another hallmark of the MM-6280IND. The device is designed to withstand harsh conditions, featuring an IP65 rating for water and dust resistance. This makes it suitable for outdoor use, ensuring that it can function reliably, even in adverse weather conditions. The rugged construction of the radio also protects it from physical impacts, reducing the risk of damage from drops or bumps.

User-friendly functionality is prioritized in the MM-6280IND, with an intuitive keypad and a clear LCD display that make navigation straightforward. It also includes programmable buttons that allow users to customize settings and features according to their specific operational requirements.

Overall, the Maxon Telecom MM-6280IND is a high-performance two-way radio that combines longevity, durability, and adaptability. Its advanced communication technologies and user-focused design make it an excellent tool for professionals seeking efficient and reliable communication solutions in various industries. Whether used for coordinating team efforts or enhancing safety and security, the MM-6280IND is a valuable asset for any organization.