Maxon Telecom MM-6280IND manual Imsi number reading, Gprs Attachment, Network registration

Page 31

3:use for set format, see below

4:manual/automatic. If manual choice fails then make an automatic registration Format possible values:

0:short alphanumeric format

1:long alphanumeric format

2:numeric format

name is operator name corresponding to the format.

Command: AT+COPS=3, format command used to change the name format

Expected response: OK Format possible values:

0:short alphanumeric format

1:long alphanumeric format

2:numeric format

1.25.2.IMSI number reading

Command: AT+CIMI

Expected response: IMSINumber

1.25.3.GPRS Attachment

Command: AT+CGATT=1

Expected response: OK or ERROR

Command: AT+CGATT?

Expected response: 1 or 0 depending on GPRS attachment

1.25.4.Network registration

UI waits for registered or Roaming status before going further. Command: AT+CREG?

Expected response: +CREG: 0,Status Status possible values:

0 : no network found

1 : registered

2 : not registered, looking for network

3 : registration denied

4 : unknown

5 : roaming

1.25.5.Own number reading

Command: AT+CNUM

Expected response: +CNUM: “String”,”OwnNumber”

HSDPA Standard At Commands

Page 31 of 60

Version 1.2

Image 31
Contents Hsdpa Standard AT Commands Manual Document Description Revision History Contact Information Table of Contents Qualcomm commands Terms definition IntroductionGeneral Terms3GPP TS ReferencesITU-T Recommendation T.32 GSM MoU SE.13ITU-T Recommendation E.212 ITU-T Recommendation T.31RFC 3748, June Ccitt RecommendationITU-T Recommendation Etsi TS 102Serial Interface Command FormatAT command Format Basic IntegrationMT2 TE2 DTE-TA/DCE interface commandsTE2 MT2 TE2-MT2 +ICF+IFC +ILRR +CMEE parameter command syntax Mobile Termination errors commandsReport Mobile Termination error +CMEE Mobile Termination error result code CME ErrorHsdpa Standard At Commands AT+CMEE=0 AT+CGMI Error AT+CMEE=1AT+CGMI +CME Error AT+CMEE=2 Informative examplesRequest manufacturer identification+CGMI General commandsRequest model identification+CGMM Request product serial number identification +CGSN +CGMM action command syntax+CGSN action command syntax +CSCS parameter command syntaxITU-T V.250 generic TA control commands Pcca STD‑101 17 select wireless network +WS46 Supported alphabets Network service commands +CNUM +CNUM action command syntaxSubscriber number +CNUM Network registration +CREG+CREG=? +CREG parameter command syntaxPlmn selection +COPS +CREG?Applicable in read command response Facility lock +CLCK When mode=2 and command successfulUnlock Lock Query status +CPWD action command syntax Change password +CPWDPreferred Plmn list +CPOL Operator information reading +COLP parameter command syntax+COPN action command syntax Read operator names +COPNOwn number reading Imsi number readingGprs Attachment Network registrationBasic TE Mobile Termination control and status commandsBasic TE Clock +CCLK Signal quality +CSQ+CSQ action command syntax +CCLK parameter command syntaxBand Selection AT$$MBAND AT$$MBAND Read CommandAT$$MBAND Write Command +CPIN parameter command syntaxPH-SIM PIN Signal strength readingPin registration Umts packet Domain commands Packet Domain CommandGPRSUmts packet Domain commands Command Req Description Support +CGDCONT=? +CGDCONT parameter command syntaxDefine PDP Context +CGDCONT +CGDCONT?PPP Define Secondary PDP Context +CGDSCONTTraffic Flow Template +CGTFT Error+CGDSCONT? + Cgtft parameter command syntax +CGTFT? +CGTFT=? + Cgqreq parameter command syntax Quality of Service Profile Requested +CGQREQ+ Cgqmin parameter command syntax Quality of Service Profile Minimum acceptable +CGQMINSDU Quality of Service Profile Requested +CGEQREQ+ Cgeqreq parameter command syntax CRLF+CGQMIN+CGEQREQ=? +CGEQREQ?Subscribed value. Other values are reserved PDPtype see +CGDCONT and +CGDSCONT commands Quality of Service Profile Minimum acceptable +CGEQMIN+CGEQMIN=? + Cgeqmin parameter command syntax+CGEQMIN? CRLF+CGEQMINFollowing parameters are defined in 3GPP TS 23.107 Quality of Service Profile Negotiated +CGEQNEG +CGEQNEG +CGEQNEG action command syntax+CGEQNEG=? PS attach or detach +CGATT + Cgact parameter command syntax + Cgatt parameter command syntaxPDP context activate or deactivate +CGACT +CGCMOD=? + Cgcmod parameter command syntaxPDP Context Modify +CGCMOD Enter data state +CGDATAShow PDP address +CGPADDR + Cgdata parameter command syntax+CGPADDR=? Modem compatibility commands+ Cgpaddr parameter command syntax Umts ConnectionSynchronous data mode commands Qualcomm command Qualcomm commandsDescription Operation Support $QCSLOT= $QCPINSTAT$QCPWRDN $QCDGEN=
Related manuals
Manual 70 pages 35.54 Kb

MM-6280IND specifications

The Maxon Telecom MM-6280IND is a robust and versatile two-way radio designed to meet the demanding needs of professionals in various fields, including security, construction, and transportation. This model stands out for its combination of advanced features, reliable performance, and user-friendly interface, making it a preferred choice for organizations requiring efficient communication solutions.

One of the key features of the MM-6280IND is its long battery life. Equipped with a high-capacity lithium-ion battery, this radio can provide extended operational time, ensuring that users can stay connected throughout their shifts without frequent recharging interruptions. Additionally, the radio supports multiple battery-saving modes, allowing users to optimize power consumption according to their needs.

The MM-6280IND operates on multiple frequency bands, ensuring compatibility across various communication networks. It supports both analog and digital communication modes, making it adaptable to different environments and user preferences. This dual-mode capability enhances interoperability, allowing seamless communication with other radios, regardless of their technology.

In terms of audio quality, the MM-6280IND features advanced noise-cancellation technology. This ensures clear audio transmission even in noisy environments, such as construction sites or crowded events. Furthermore, the radio is equipped with a built-in speaker and microphone that deliver crisp and loud audio, allowing users to communicate effectively without straining their ears.

Durability is another hallmark of the MM-6280IND. The device is designed to withstand harsh conditions, featuring an IP65 rating for water and dust resistance. This makes it suitable for outdoor use, ensuring that it can function reliably, even in adverse weather conditions. The rugged construction of the radio also protects it from physical impacts, reducing the risk of damage from drops or bumps.

User-friendly functionality is prioritized in the MM-6280IND, with an intuitive keypad and a clear LCD display that make navigation straightforward. It also includes programmable buttons that allow users to customize settings and features according to their specific operational requirements.

Overall, the Maxon Telecom MM-6280IND is a high-performance two-way radio that combines longevity, durability, and adaptability. Its advanced communication technologies and user-focused design make it an excellent tool for professionals seeking efficient and reliable communication solutions in various industries. Whether used for coordinating team efforts or enhancing safety and security, the MM-6280IND is a valuable asset for any organization.