value
<fac> values reserved by the present document:
"CS" CNTRL (lock CoNTRoL surface (e.g. phone keyboard))
"PS"
"PF" lock Phone to the very First inserted SIM/UICC card (also referred in the present document as
"SC" SIM (lock SIM/UICC card) (SIM/UICC asks password in MT
"AO" BAOC (Barr All Outgoing Calls) (refer 3GPP TS 22.088 [6] clause 1) "OI" BOIC (Barr Outgoing International Calls) (refer 3GPP TS 22.088 [6]
clause 1)
"OX"
"AI" BAIC (Barr All Incoming Calls) (refer 3GPP TS 22.088 [6] clause 2) "IR"
country) (refer 3GPP TS 22.088 [6] clause 2)
"NT" barr incoming calls from numbers Not stored to TA memory "NM" barr incoming calls from numbers Not stored to MT memory "NS" barr incoming calls from numbers Not stored to SIM/UICC memory "NA" barr incoming calls from numbers Not stored in Any memory "AB" All Barring services (refer 3GPP TS 22.030 [19]) (applicable only for
<mode>=0)
"AG" All outGoing barring services (refer 3GPP TS 22.030 [19]) (applicable only for <mode>=0)
"AC" All inComing barring services (refer 3GPP TS 22.030 [19]) (applicable only for <mode>=0)
"FD" SIM card or active application in the UICC (GSM or USIM) fixed dialling memory feature (if PIN2 authentication has not been done during the current session, PIN2 is required as <passwd>)
"PN" Network Personalization (refer 3GPP TS 22.022 [33]) "PU" network sUbset Personalization (refer 3GPP TS 22.022 [33]) "PP" service Provider Personalization (refer 3GPP TS 22.022 [33]) "PC" Corporate Personalization (refer 3GPP TS 22.022 [33])
<mode>:
0unlock
1lock
2query status
<status>:
0not active
1active
<passwd>: string type; shall be the same as password specified for the facility from the MT user interface or with command Change Password +CPWD
<classx> is a sum of integers each representing a class of information (default 7):
1voice (telephony)
2data (refers to all bearer services; with <mode>=2 this may refer only to
some bearer service if TA does not support values 16, 32, 64 and 128)
4fax (facsimile services)
8short message service
16data circuit sync
32data circuit async
64dedicated packet access
128dedicated PAD access
HSDPA Standard At Commands | Page 28 of 60 | Version 1.2 |