Maxon Telecom MM-6280IND manual Facility lock +CLCK, When mode=2 and command successful

Page 27

2current

3forbidden

<AcT> access technology selected:

0GSM

1GSM Compact

2UTRAN

1.21.Facility lock +CLCK

Execute command is used to lock, unlock or interrogate a MT or a network facility <fac>. Password is normally needed to do such actions. When querying the status of a network service (<mode>=2) the response line for 'not active' case (<status>=0) should be returned only if service is not active for any <class>.

. This command should be abortable when network facilities are set or interrogated.

Call barring facilities are based on GSM/UMTS supplementary services (refer 3GPP TS 22.088 [6]). The interaction of these with other commands based on other GSM/UMTS supplementary services is described in the GSM/UMTS standard.

Test command returns facility values supported as a compound value.

Table 17. +CREG parameter command syntax

Command

 

Possible response(s)

+CLCK=<fac>,<mode>[,<

+CME ERROR: <err>

 

passwd>[,<class>]]

when <mode>=2 and command successful:

 

+CLCK: <status>[,<class1>

 

[<CR><LF>+CLCK: <status>,<class2>

 

[...]]

 

 

+CLCK=?

+CLCK:

(list of supported

s

 

 

<fac> )

 

+CME ERROR: <err>

 

HSDPA Standard At Commands

Page 27 of 60

Version 1.2

Image 27
Contents Hsdpa Standard AT Commands Manual Document Description Revision History Contact Information Table of Contents Qualcomm commands Terms definition IntroductionGeneral Terms3GPP TS ReferencesITU-T Recommendation T.32 GSM MoU SE.13ITU-T Recommendation E.212 ITU-T Recommendation T.31RFC 3748, June Ccitt RecommendationITU-T Recommendation Etsi TS 102Serial Interface Command FormatAT command Format Basic IntegrationDTE-TA/DCE interface commands MT2 TE2TE2 MT2 +ICF TE2-MT2+IFC +ILRR +CMEE parameter command syntax Mobile Termination errors commandsReport Mobile Termination error +CMEE Mobile Termination error result code CME ErrorHsdpa Standard At Commands AT+CMEE=0 AT+CGMI Error AT+CMEE=1AT+CGMI +CME Error AT+CMEE=2 Informative examplesGeneral commands Request manufacturer identification+CGMIRequest model identification+CGMM Request product serial number identification +CGSN +CGMM action command syntax+CGSN action command syntax +CSCS parameter command syntaxITU-T V.250 generic TA control commands Pcca STD‑101 17 select wireless network +WS46 Supported alphabets Network service commands +CNUM +CNUM action command syntaxSubscriber number +CNUM Network registration +CREG+CREG=? +CREG parameter command syntaxPlmn selection +COPS +CREG?Applicable in read command response Facility lock +CLCK When mode=2 and command successfulUnlock Lock Query status Change password +CPWD +CPWD action command syntaxPreferred Plmn list +CPOL Operator information reading +COLP parameter command syntax+COPN action command syntax Read operator names +COPNOwn number reading Imsi number readingGprs Attachment Network registrationMobile Termination control and status commands Basic TEBasic TE Clock +CCLK Signal quality +CSQ+CSQ action command syntax +CCLK parameter command syntaxBand Selection AT$$MBAND AT$$MBAND Read CommandAT$$MBAND Write Command +CPIN parameter command syntaxPH-SIM PIN Signal strength readingPin registration Packet Domain CommandGPRS Umts packet Domain commandsUmts packet Domain commands Command Req Description Support +CGDCONT=? +CGDCONT parameter command syntaxDefine PDP Context +CGDCONT +CGDCONT?PPP Define Secondary PDP Context +CGDSCONTError Traffic Flow Template +CGTFT+CGDSCONT? + Cgtft parameter command syntax +CGTFT? +CGTFT=? + Cgqreq parameter command syntax Quality of Service Profile Requested +CGQREQ+ Cgqmin parameter command syntax Quality of Service Profile Minimum acceptable +CGQMINSDU Quality of Service Profile Requested +CGEQREQ+ Cgeqreq parameter command syntax CRLF+CGQMIN+CGEQREQ=? +CGEQREQ?Subscribed value. Other values are reserved PDPtype see +CGDCONT and +CGDSCONT commands Quality of Service Profile Minimum acceptable +CGEQMIN+CGEQMIN=? + Cgeqmin parameter command syntax+CGEQMIN? CRLF+CGEQMINFollowing parameters are defined in 3GPP TS 23.107 Quality of Service Profile Negotiated +CGEQNEG +CGEQNEG action command syntax +CGEQNEG+CGEQNEG=? PS attach or detach +CGATT + Cgatt parameter command syntax + Cgact parameter command syntaxPDP context activate or deactivate +CGACT +CGCMOD=? + Cgcmod parameter command syntaxPDP Context Modify +CGCMOD Enter data state +CGDATAShow PDP address +CGPADDR + Cgdata parameter command syntax+CGPADDR=? Modem compatibility commands+ Cgpaddr parameter command syntax Umts ConnectionSynchronous data mode commands Qualcomm commands Qualcomm commandDescription Operation Support $QCSLOT= $QCPINSTAT$QCPWRDN $QCDGEN=
Related manuals
Manual 70 pages 35.54 Kb

MM-6280IND specifications

The Maxon Telecom MM-6280IND is a robust and versatile two-way radio designed to meet the demanding needs of professionals in various fields, including security, construction, and transportation. This model stands out for its combination of advanced features, reliable performance, and user-friendly interface, making it a preferred choice for organizations requiring efficient communication solutions.

One of the key features of the MM-6280IND is its long battery life. Equipped with a high-capacity lithium-ion battery, this radio can provide extended operational time, ensuring that users can stay connected throughout their shifts without frequent recharging interruptions. Additionally, the radio supports multiple battery-saving modes, allowing users to optimize power consumption according to their needs.

The MM-6280IND operates on multiple frequency bands, ensuring compatibility across various communication networks. It supports both analog and digital communication modes, making it adaptable to different environments and user preferences. This dual-mode capability enhances interoperability, allowing seamless communication with other radios, regardless of their technology.

In terms of audio quality, the MM-6280IND features advanced noise-cancellation technology. This ensures clear audio transmission even in noisy environments, such as construction sites or crowded events. Furthermore, the radio is equipped with a built-in speaker and microphone that deliver crisp and loud audio, allowing users to communicate effectively without straining their ears.

Durability is another hallmark of the MM-6280IND. The device is designed to withstand harsh conditions, featuring an IP65 rating for water and dust resistance. This makes it suitable for outdoor use, ensuring that it can function reliably, even in adverse weather conditions. The rugged construction of the radio also protects it from physical impacts, reducing the risk of damage from drops or bumps.

User-friendly functionality is prioritized in the MM-6280IND, with an intuitive keypad and a clear LCD display that make navigation straightforward. It also includes programmable buttons that allow users to customize settings and features according to their specific operational requirements.

Overall, the Maxon Telecom MM-6280IND is a high-performance two-way radio that combines longevity, durability, and adaptability. Its advanced communication technologies and user-focused design make it an excellent tool for professionals seeking efficient and reliable communication solutions in various industries. Whether used for coordinating team efforts or enhancing safety and security, the MM-6280IND is a valuable asset for any organization.