+CGTFT: <cid>, <packet filter identifier>, <evaluation precedence index>, <source address and subnet mask>, <protocol number (ipv4) / next header (ipv6)>, <destination port range>, <source port range>, <ipsec security parameter index (spi)>, <type of service (tos) (ipv4) and mask / traffic class (ipv6) and mask>, <flow label (ipv6)>

[<CR><LF>+CGTFT: <cid>, <packet filter identifier>, <evaluation precedence index>, <source address and subnet mask>, <protocol number (ipv4) / next header (ipv6)>, <destination port range>, <source port range>, <ipsec security parameter index (spi)>, <type of service (tos) (ipv4) and mask / traffic class (ipv6) and mask>, <flow label (ipv6)>

[…]]

+CGTFT: <PDP_type>, (list of supported <packet filter identifier>s), (list of supported <evaluation precedence index>s), (list of supported <source address and subnet mask>s), (list of supported <protocol number (ipv4) / next header (ipv6)>s), (list of supported <destination port range>s), (list of supported <source port range>s), (list of supported <ipsec security parameter index (spi)>s), (list of supported <type of service (tos) (ipv4) and mask / traffic class (ipv6) and mask>s), (list of supported <flow label (ipv6)>s)

[<CR><LF>+CGTFT: <PDP_type>, (list of supported <packet filter identifier>s), (list of supported <evaluation precedence index>s), (list of supported <source address and subnet mask>s), (list of supported <protocol number (ipv4) / next header (ipv6)>s), (list of supported <destination port range>s), (list of supported <source port range>s), (list of supported <ipsec security parameter index (spi)>s), (list of supported <type of service (tos) (ipv4) and mask / traffic class (ipv6) and mask>s), (list of supported <flow label (ipv6)>s)

[…]]

<cid>: a numeric parameter which specifies a particular PDP context definition (see the +CGDCONT and +CGDSCONT commands).

The following parameters are defined in 3GPP TS 23.060[47] -

<packet filter identifier>: Numeric parameter, value range from 1 to 8.

<source address and subnet mask>: Consists of dot-separated numeric (0-255) parameters on the form 'a1.a2.a3.a4.m1.m2.m3.m4', for IPv4 and 'a1.a2.a3.a4.a5.a6.a7.a8.a9.a10.a11.a12.a13.a14.a15.a16. m1.m2.m3.m4.m5.m6.m7.m8.m9.m10.m11.m12.m13.m14.m15.m16', for IPv6.

<protocol number (ipv4) / next header (ipv6)>: Numeric parameter, value range from 0 to 255.

<destination port range>: Consists of dot-separated numeric (0-65535)

HSDPA Standard At Commands

Page 42 of 60

Version 1.2

Image 42
Contents Hsdpa Standard AT Commands Manual Document Description Revision History Contact Information Table of Contents Qualcomm commands Terms IntroductionGeneral Terms definitionReferences 3GPP TSITU-T Recommendation T.31 GSM MoU SE.13ITU-T Recommendation E.212 ITU-T Recommendation T.32Etsi TS 102 Ccitt RecommendationITU-T Recommendation RFC 3748, JuneBasic Integration Command FormatAT command Format Serial InterfaceDTE-TA/DCE interface commands MT2 TE2TE2 MT2 +ICF TE2-MT2+IFC +ILRR Mobile Termination error result code CME Error Mobile Termination errors commandsReport Mobile Termination error +CMEE +CMEE parameter command syntaxHsdpa Standard At Commands Informative examples AT+CGMI Error AT+CMEE=1AT+CGMI +CME Error AT+CMEE=2 AT+CMEE=0General commands Request manufacturer identification+CGMIRequest model identification+CGMM +CSCS parameter command syntax +CGMM action command syntax+CGSN action command syntax Request product serial number identification +CGSNITU-T V.250 generic TA control commands Pcca STD‑101 17 select wireless network +WS46 Supported alphabets Network service commands Network registration +CREG +CNUM action command syntaxSubscriber number +CNUM +CNUM+CREG? +CREG parameter command syntaxPlmn selection +COPS +CREG=?Applicable in read command response When mode=2 and command successful Facility lock +CLCKUnlock Lock Query status Change password +CPWD +CPWD action command syntaxPreferred Plmn list +CPOL Read operator names +COPN +COLP parameter command syntax+COPN action command syntax Operator information readingNetwork registration Imsi number readingGprs Attachment Own number readingMobile Termination control and status commands Basic TEBasic TE +CCLK parameter command syntax Signal quality +CSQ+CSQ action command syntax Clock +CCLK+CPIN parameter command syntax AT$$MBAND Read CommandAT$$MBAND Write Command Band Selection AT$$MBANDSignal strength reading PH-SIM PINPin registration Packet Domain CommandGPRS Umts packet Domain commandsUmts packet Domain commands Command Req Description Support +CGDCONT? +CGDCONT parameter command syntaxDefine PDP Context +CGDCONT +CGDCONT=? Define Secondary PDP Context +CGDSCONT PPPError Traffic Flow Template +CGTFT+CGDSCONT? + Cgtft parameter command syntax +CGTFT? +CGTFT=? Quality of Service Profile Requested +CGQREQ + Cgqreq parameter command syntaxQuality of Service Profile Minimum acceptable +CGQMIN + Cgqmin parameter command syntaxCRLF+CGQMIN Quality of Service Profile Requested +CGEQREQ+ Cgeqreq parameter command syntax SDU+CGEQREQ? +CGEQREQ=?Subscribed value. Other values are reserved Quality of Service Profile Minimum acceptable +CGEQMIN PDPtype see +CGDCONT and +CGDSCONT commandsCRLF+CGEQMIN + Cgeqmin parameter command syntax+CGEQMIN? +CGEQMIN=?Following parameters are defined in 3GPP TS 23.107 Quality of Service Profile Negotiated +CGEQNEG +CGEQNEG action command syntax +CGEQNEG+CGEQNEG=? PS attach or detach +CGATT + Cgatt parameter command syntax + Cgact parameter command syntaxPDP context activate or deactivate +CGACT Enter data state +CGDATA + Cgcmod parameter command syntaxPDP Context Modify +CGCMOD +CGCMOD=?+ Cgdata parameter command syntax Show PDP address +CGPADDRUmts Connection Modem compatibility commands+ Cgpaddr parameter command syntax +CGPADDR=?Synchronous data mode commands Qualcomm commands Qualcomm commandDescription Operation Support $QCDGEN= $QCPINSTAT$QCPWRDN $QCSLOT=