Maxon Telecom MM-6280IND manual General commands, Request manufacturer identification+CGMI

Page 18

General commands

ITU-T Recommendation V.250 [14] includes "Generic DCE Control" commands with the prefix +G. These commands are for the identification of the TA. Four of those commands are adapted here to be the identification commands of the MT. Syntax is otherwise similar but the prefix is +CG. TIA IS-99 [15] uses same commands for base station identification.

Table 6. General AT command

Command

Req

Description

 

Support

+CGMI

Opt.

Request manufacturer identification

 

supported

 

 

 

 

+CGMM

Opt.

Request model identification

 

supported

 

 

 

 

+CGMR

Opt.

Request revision identification

 

supported

 

 

 

 

+CGSN

Opt.

Request product serial number identification

 

supported

 

 

 

 

+CSCS

Mand.

Select TE character set

 

supported

 

 

 

 

+CIMI

Opt.

Request international mobile subscriber identity

 

supported

 

 

 

 

+CMUX

 

Multiplexing mode

 

Not supported

 

 

 

 

 

1.11. Request manufacturer identification(+CGMI)

Execution command causes the TA to return one or more lines of information text <manufacturer>, determined by the MT manufacturer, which is intended to permit the user of the TA to identify the manufacturer of the MT to which it is connected to. Typically, the text will consist of a single line containing the name of the manufacturer, but manufacturers may choose to provide more information if desired.

Table 7. +CGMI action command syntax

Command

Possible response(s)

+CGMI

<manufacturer>

 

+CME ERROR: <err>

+CGMI=?

 

value

<manufacturer>: the total number of characters, including line terminators, in the

 

information text shall not exceed 2048 characters

1.12. Request model identification(+CGMM )

Execution command causes the TA to return one or more lines of information text <model>, determined by the MT manufacturer, which is intended to permit the user of the TA to identify the specific model of the MT to which it is connected to. Typically, the text will consist of a single line containing the name of the product, but manufacturers may choose to provide more information if desired.

HSDPA Standard At Commands

Page 18 of 60

Version 1.2

Image 18
Contents Hsdpa Standard AT Commands Manual Document Description Revision History Contact Information Table of Contents Qualcomm commands Terms IntroductionGeneral Terms definitionReferences 3GPP TSITU-T Recommendation T.31 GSM MoU SE.13ITU-T Recommendation E.212 ITU-T Recommendation T.32Etsi TS 102 Ccitt RecommendationITU-T Recommendation RFC 3748, JuneBasic Integration Command FormatAT command Format Serial InterfaceDTE-TA/DCE interface commands MT2 TE2TE2 MT2 +ICF TE2-MT2+IFC +ILRR Mobile Termination error result code CME Error Mobile Termination errors commands Report Mobile Termination error +CMEE +CMEE parameter command syntaxHsdpa Standard At Commands Informative examples AT+CGMI Error AT+CMEE=1AT+CGMI +CME Error AT+CMEE=2 AT+CMEE=0General commands Request manufacturer identification+CGMIRequest model identification+CGMM +CSCS parameter command syntax +CGMM action command syntax+CGSN action command syntax Request product serial number identification +CGSNITU-T V.250 generic TA control commands Pcca STD‑101 17 select wireless network +WS46 Supported alphabets Network service commands Network registration +CREG +CNUM action command syntaxSubscriber number +CNUM +CNUM+CREG? +CREG parameter command syntaxPlmn selection +COPS +CREG=?Applicable in read command response When mode=2 and command successful Facility lock +CLCKUnlock Lock Query status Change password +CPWD +CPWD action command syntaxPreferred Plmn list +CPOL Read operator names +COPN +COLP parameter command syntax+COPN action command syntax Operator information readingNetwork registration Imsi number readingGprs Attachment Own number readingMobile Termination control and status commands Basic TEBasic TE +CCLK parameter command syntax Signal quality +CSQ+CSQ action command syntax Clock +CCLK+CPIN parameter command syntax AT$$MBAND Read CommandAT$$MBAND Write Command Band Selection AT$$MBANDSignal strength reading PH-SIM PINPin registration Packet Domain CommandGPRS Umts packet Domain commandsUmts packet Domain commands Command Req Description Support +CGDCONT? +CGDCONT parameter command syntaxDefine PDP Context +CGDCONT +CGDCONT=?Define Secondary PDP Context +CGDSCONT PPPError Traffic Flow Template +CGTFT+CGDSCONT? + Cgtft parameter command syntax +CGTFT? +CGTFT=? Quality of Service Profile Requested +CGQREQ + Cgqreq parameter command syntaxQuality of Service Profile Minimum acceptable +CGQMIN + Cgqmin parameter command syntaxCRLF+CGQMIN Quality of Service Profile Requested +CGEQREQ+ Cgeqreq parameter command syntax SDU+CGEQREQ? +CGEQREQ=?Subscribed value. Other values are reserved Quality of Service Profile Minimum acceptable +CGEQMIN PDPtype see +CGDCONT and +CGDSCONT commandsCRLF+CGEQMIN + Cgeqmin parameter command syntax+CGEQMIN? +CGEQMIN=?Following parameters are defined in 3GPP TS 23.107 Quality of Service Profile Negotiated +CGEQNEG +CGEQNEG action command syntax +CGEQNEG+CGEQNEG=? PS attach or detach +CGATT + Cgatt parameter command syntax + Cgact parameter command syntaxPDP context activate or deactivate +CGACT Enter data state +CGDATA + Cgcmod parameter command syntaxPDP Context Modify +CGCMOD +CGCMOD=?+ Cgdata parameter command syntax Show PDP address +CGPADDRUmts Connection Modem compatibility commands+ Cgpaddr parameter command syntax +CGPADDR=?Synchronous data mode commands Qualcomm commands Qualcomm commandDescription Operation Support $QCDGEN= $QCPINSTAT$QCPWRDN $QCSLOT=