Z[<value>]

Mand.

TA sets all parameters to their defaults as specified by a

 

supported

 

 

 

user memory profile or by the manufacturer, and resets TA

 

 

 

 

 

 

&F[<value>]

Mand.

 

TA sets all parameters to their defaults as specified by the

 

supported

 

 

 

manufacturer

 

 

 

 

 

 

 

 

I[<value>]

Opt.

 

request

manufacturer specific information

about the

 

supported

 

 

 

TA (software cannot use this command to determine the

 

 

 

 

 

 

 

 

 

capabilities of a TA)

 

 

 

+GMI

Mand.

 

This command causes the MT2 to transmit one or more

 

supported

 

 

 

 

 

 

 

lines of information text, determined by the manufacturer,

 

 

 

 

 

which is intended to permit the user of the MT2 to identify

 

 

 

 

 

the manufacturer. Typically, the text will consist of a single

 

 

 

 

 

line containing the name of the manufacturer, but

 

 

 

 

 

manufacturers may choose to provide more information if

 

 

 

 

 

desired (e.g., address, telephone number for customer

 

 

 

 

 

service, etc.).

 

 

 

 

 

 

Maxon Electronics Australia Pty. Ltd.

 

 

 

+GMM

Mand.

 

This command causes the MT2 to transmit one or more

 

supported

 

 

 

 

 

 

 

lines of information text, determined by the manufacturer,

 

 

 

 

 

which is intended to permit the user of the MT2 to identify

 

 

 

 

 

the specific model of the device. Typically, the text will

 

 

 

 

 

consist of a single line containing the name of the product,

 

 

 

 

 

but manufacturers may choose to provide any information

 

 

 

 

 

desired.

 

 

 

 

+GMR

Mand.

 

This command causes the MT2 to transmit one or more

 

supported

 

 

 

 

 

 

 

lines of information text, determined by the manufacturer,

 

 

 

 

 

which is intended to permit the user of the MT2 to identify

 

 

 

 

 

the version, revision level or date, or other pertinent

 

 

 

 

 

information of the device. Typically, the text will consist of a

 

 

 

 

 

single line containing the version of the product, but

 

 

 

 

 

manufacturers may choose to provide any information

 

 

 

 

 

desired.

 

 

 

 

+GSN

Opt.

 

This command causes the MT2 to transmit one or more

 

supported

 

 

 

lines of information text, determined by the manufacturer,

 

 

 

 

 

 

 

 

 

which is intended to permit the user of the MT2 to identify

 

 

 

 

 

the individual device. Typically, the text will consist of a

 

 

 

 

 

single line containing a manufacturer determined alpha-

 

 

 

 

 

numeric string, but manufacturers may choose to provide

 

 

 

 

 

any information desired.

 

 

 

+GOI

Opt.

 

request ISO system global object identification of the TA

 

Not supported

 

 

 

(general format defined in ITU T Recommendation X.208;

 

 

 

 

 

encoding rules in ITU T Recommendation X.209)

 

 

+GCAP

Mand.

 

This extended-format command causes the MT2 to

 

supported

 

 

 

 

 

 

 

transmit one or more lines of information text in a specific

 

 

 

 

 

format. The content is a list of additional capabilities

 

 

HSDPA Standard At Commands

Page 20 of 60

Version 1.2

 

Image 20
Contents Hsdpa Standard AT Commands Manual Document Description Revision History Contact Information Table of Contents Qualcomm commands Introduction GeneralTerms Terms definitionReferences 3GPP TSGSM MoU SE.13 ITU-T Recommendation E.212ITU-T Recommendation T.31 ITU-T Recommendation T.32Ccitt Recommendation ITU-T RecommendationEtsi TS 102 RFC 3748, JuneCommand Format AT command FormatBasic Integration Serial InterfaceTE2 MT2 DTE-TA/DCE interface commandsMT2 TE2 +IFC +ICFTE2-MT2 +ILRR Mobile Termination errors commands Report Mobile Termination error +CMEEMobile Termination error result code CME Error +CMEE parameter command syntaxHsdpa Standard At Commands AT+CGMI Error AT+CMEE=1 AT+CGMI +CME Error AT+CMEE=2Informative examples AT+CMEE=0Request model identification+CGMM General commandsRequest manufacturer identification+CGMI +CGMM action command syntax +CGSN action command syntax+CSCS parameter command syntax Request product serial number identification +CGSNITU-T V.250 generic TA control commands Pcca STD‑101 17 select wireless network +WS46 Supported alphabets Network service commands +CNUM action command syntax Subscriber number +CNUMNetwork registration +CREG +CNUM+CREG parameter command syntax Plmn selection +COPS+CREG? +CREG=?Applicable in read command response When mode=2 and command successful Facility lock +CLCKUnlock Lock Query status Preferred Plmn list +CPOL Change password +CPWD+CPWD action command syntax +COLP parameter command syntax +COPN action command syntaxRead operator names +COPN Operator information readingImsi number reading Gprs AttachmentNetwork registration Own number readingBasic TE Mobile Termination control and status commandsBasic TE Signal quality +CSQ +CSQ action command syntax+CCLK parameter command syntax Clock +CCLKAT$$MBAND Read Command AT$$MBAND Write Command+CPIN parameter command syntax Band Selection AT$$MBANDSignal strength reading PH-SIM PINPin registration Umts packet Domain commands Command Req Description Support Packet Domain CommandGPRSUmts packet Domain commands +CGDCONT parameter command syntax Define PDP Context +CGDCONT+CGDCONT? +CGDCONT=?Define Secondary PDP Context +CGDSCONT PPP+CGDSCONT? ErrorTraffic Flow Template +CGTFT + Cgtft parameter command syntax +CGTFT? +CGTFT=? Quality of Service Profile Requested +CGQREQ + Cgqreq parameter command syntaxQuality of Service Profile Minimum acceptable +CGQMIN + Cgqmin parameter command syntaxQuality of Service Profile Requested +CGEQREQ + Cgeqreq parameter command syntaxCRLF+CGQMIN SDU+CGEQREQ? +CGEQREQ=?Subscribed value. Other values are reserved Quality of Service Profile Minimum acceptable +CGEQMIN PDPtype see +CGDCONT and +CGDSCONT commands+ Cgeqmin parameter command syntax +CGEQMIN?CRLF+CGEQMIN +CGEQMIN=?Following parameters are defined in 3GPP TS 23.107 Quality of Service Profile Negotiated +CGEQNEG +CGEQNEG=? +CGEQNEG action command syntax+CGEQNEG PS attach or detach +CGATT PDP context activate or deactivate +CGACT + Cgatt parameter command syntax+ Cgact parameter command syntax + Cgcmod parameter command syntax PDP Context Modify +CGCMODEnter data state +CGDATA +CGCMOD=?+ Cgdata parameter command syntax Show PDP address +CGPADDRModem compatibility commands + Cgpaddr parameter command syntaxUmts Connection +CGPADDR=?Synchronous data mode commands Description Operation Support Qualcomm commandsQualcomm command $QCPINSTAT $QCPWRDN$QCDGEN= $QCSLOT=
Related manuals
Manual 70 pages 35.54 Kb

MM-6280IND specifications

The Maxon Telecom MM-6280IND is a robust and versatile two-way radio designed to meet the demanding needs of professionals in various fields, including security, construction, and transportation. This model stands out for its combination of advanced features, reliable performance, and user-friendly interface, making it a preferred choice for organizations requiring efficient communication solutions.

One of the key features of the MM-6280IND is its long battery life. Equipped with a high-capacity lithium-ion battery, this radio can provide extended operational time, ensuring that users can stay connected throughout their shifts without frequent recharging interruptions. Additionally, the radio supports multiple battery-saving modes, allowing users to optimize power consumption according to their needs.

The MM-6280IND operates on multiple frequency bands, ensuring compatibility across various communication networks. It supports both analog and digital communication modes, making it adaptable to different environments and user preferences. This dual-mode capability enhances interoperability, allowing seamless communication with other radios, regardless of their technology.

In terms of audio quality, the MM-6280IND features advanced noise-cancellation technology. This ensures clear audio transmission even in noisy environments, such as construction sites or crowded events. Furthermore, the radio is equipped with a built-in speaker and microphone that deliver crisp and loud audio, allowing users to communicate effectively without straining their ears.

Durability is another hallmark of the MM-6280IND. The device is designed to withstand harsh conditions, featuring an IP65 rating for water and dust resistance. This makes it suitable for outdoor use, ensuring that it can function reliably, even in adverse weather conditions. The rugged construction of the radio also protects it from physical impacts, reducing the risk of damage from drops or bumps.

User-friendly functionality is prioritized in the MM-6280IND, with an intuitive keypad and a clear LCD display that make navigation straightforward. It also includes programmable buttons that allow users to customize settings and features according to their specific operational requirements.

Overall, the Maxon Telecom MM-6280IND is a high-performance two-way radio that combines longevity, durability, and adaptability. Its advanced communication technologies and user-focused design make it an excellent tool for professionals seeking efficient and reliable communication solutions in various industries. Whether used for coordinating team efforts or enhancing safety and security, the MM-6280IND is a valuable asset for any organization.