RAD Data comm ASMI-450 operation manual DSP ST Port, Purpose Format Use Display Format

Page 78
REM REM PORT: remote port loopback
ASMi-450 Installation and Operation Manual
Displays the type of the user's port interface ('interface' stands for the interface type: V.35, X.21, RS-422,RS-530, or ETHERNET). Displays the state of each type of loopback that can be activated ACTIVATED LOOPS by command from the local ASMi-450 unit on either the local, or the remote unit:
LOCAL PORT: local port loopback on the local unit.

ASMi-450 Control from the Control Port

Display Format

A typical HDSL line status display is shown below.

 

STATUS OF LINE

 

ANALOG FRONT END TYPE = 784K

 

LOCAL LINE ALARMS = SYNC LOSS

SIGNAL LOSS

OFF

OFF

The fields included in the status information display are listed below:

ANALOG FRONT END TYPE Displays the nominal data rate on the HDSL line:

 

784 kbps for ASMi-450/768.

LINE ALARMS

Displays the state of the line alarms on the HDSL

 

line:

 

 

SIGNAL LOSS

ON indicates loss of HDSL

 

 

input signal.

 

SYNC LOSS

ON indicates loss of

 

 

synchronization to the HDSL

 

 

signal.

DSP ST PORT -------------------------------------------------------------------------------

Purpose

Format

Use

Display Format

Display status information on the user's port.

DSP ST PORT [Option]

1.To display the current status information for the user's port, type:

DSP ST PORT

A typical user's port status display is shown below.

STATUS OF PORT

 

 

 

INTERFACE TYPE

=

'interface'

 

LOCAL UNIT ACTIVATED LOOPS

=

LOCAL PORT

REM REM PORT

 

 

NO

NO

REMOTE UNIT INITIATED LOOPS =

REM PORT

 

 

 

NO

 

The fields included in the ASMi-450 status information display are listed below:

TYPE

LOCAL UNIT

4-20

Image 78
Contents ASMi-450 Warranty Selv HdslRegulatory Information Declaration of Conformity Page Contents ASMi-450 Control from the Control Port Appendix a Connector Wiring Contents List of Figures List of Figures Xii List of Tables List of Tables Xiv Starting the Configuration Preliminary Preparations Starting ProcedureConfiguration Procedure Step Action Use the CommandFunction Terminal Type TV920 VT52 VT100 Freedom 100/110 Command Index Type Configuration Display Commands Control CommandsQuick-Start Guide Purpose and Main Features Functional DescriptionTypical Application for ASMi-450 with Data Interface Hdsl Subsystem Characteristics System Timing Internal timingControl ASMi-450 Operation Local ControlRemote Management Introduction Physical Characteristics Test and Diagnostics CapabilitiesAlarms Power RequirementsTransmission Media Hdsl Line Signal Binary Digits Quaternary SymbolOperating Environment Hdsl Signal Structure HDSL-Related System Functions Technical Specifications Hdsl InterfaceEthernet Interface Physical Characteristics Chapter Installation GeneralUnpacking Site RequirementsASMi-450 Configuration Information GeneralOpening ASMi-450 Case Jumper and Switch Location Functions Switch S1ASMi-450 Internal Settings OFF Internal Settings Procedure Reinstalling ASMi-450 Cover Jumper R/CJumper FGND/GND Connector Location Grounding Power Connection Users Port Connections AC Power ConnectionDC Power Connection Hdsl Line Connections Control Port Connection Chapter Front-Panel Operating Instructions ScopeFront Panel Controls, Connectors, and Indicators Control or Indicator FunctionIndicators Indicator FunctionEthernet Interface Control of ASMi-450 Operation, General General General Operating Instructions Display FunctionsTest Functions Configuration ParametersStatus Messages Display Description SeeASMi-450 Display Using Front-PanelOrganization Push-buttonsFront-Panel Operating Instructions System Configuration Parameters Designation Function ValuesControl Port Configuration Parameters Turn-on Checking Current Operating Configuration Operating InstructionsDisplay CursorScroll Normal Front-Panel Indications Fault IndicationsStep Action Key Display Ethernet Interface IndicationsConfiguration Procedure Local Configuration Set-Up ProcedurePassword ProtectionAlready there Scroll to display the desired group Specific Configuration Guidelines Alarm BufferSP Parameters LCD Configuration Error Messages Front-Panel Operating Instructions Chapter ASMi-450 Control from the Control Port Hardware Requirements Request to Send RTS Interface TypeData Terminal Ready DTR Clear to Send CTSAutobaud Function Ring Indication RIData Set Ready DSR Preparation for Use of Supervision Terminal Internal SettingsControl Port Configuration ASMi-450 Preparations Supervision Terminal ConnectionsASMi-450 Supervision Language Command Language Syntax Command OptionsCommand Protocol Option Meaning Example of UsageIndex of Commands Command Purpose Options CLR Loop ASMi-450 Command Set DescriptionCLR ALM FormatCLR TST DateDEF Agent DEF Name Display FieldsDEF Node DEF PWDDEF SP Purpose Format UsePWD DEF SYS DEF TermDSP ALM Function Terminal Type VT-52 VT-100 Freedom-110Format Use Alarm No Alarm Syntax Meaning State Time Quality Alarm Remote AlarmRemote Signal Loss Remote DBREM LAN not DSP HDR TSTDSP ST Line ConnectedDSP ST Port Display FormatPurpose Format Use Display Format DSP ST SYS ExitHelp Parameter Designation Default Value Init DBPassword LoopNode Reset TimeStarting a Session Single ASMi-450 Control Session Ending a Control Session Configuration Error Messages ASMi-450 Control from the Control Port Indicators Display Status Indications and MessagesMessage Description Corrective Actions Alarm ON/OFFASMi-450 Alarm Buffer Messages Cont’d Remote Alarm Remote Reverse Test Functions Test FunctionsLoop REM REM Port Operating InstructionsPower-Up Self-Test Activating the Test Functions from a Control TerminalTroubleshooting Instructions Trouble Symptoms Probable Cause Corrective MeasuresLAN RS-530 DCE Connector and Adapter Cables Pin Designation Direction FunctionPin Designation Direction Function 36/RS-449/422 RceaRceb V.35 DCE Connector X.21 DCE Connector Pin Function Hdsl Line ConnectorRS-232 V.24 Control Port Connector Pin Line Connected Connected to To TerminalEthernet Interface Connector Appendix B Snmp Management Snmp Environment General Snmp PrinciplesSnmp Operations Management Information Base MIB StructureMIBs Supported by the ASMi-450 Snmp Agent Access Restriction Using Snmp Communities Management Domains UnderSnmp Communities ASMi-450 Communities ReadIP Address Structure IP EnvironmentGeneral IP Environment Address Class First Byte Address RangeSnmp Management Snmp Traps Appendix C Installation in 19 Racks Installation of Single Unit Figure C-1. Installation of Single Unit in 19 RackInstallation of Two Units General PreparationsFastening the Two Units To install the ferrite cores ASMi-450