RAD Data comm ASMI-450 operation manual Remote Alarm

Page 92

Diagnostics

Table 5-1. ASMi-450 Alarm Buffer Messages (Cont’d)

Message

Description

 

Corrective Actions

Alarm

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

REMOTE ALARM

More than 256 alarms entries have

Read the messages and then clear the

ON/OFF

BUFFER OVERFLOW

been written in the alarm buffer of

buffer:

 

 

the remote ASMi-450 since the last

-

If you are using the front panel,

 

 

clear command. New alarms are

 

delete all the event alarms by

 

 

overwriting the older alarms

 

selecting CLEAR.

 

 

 

-

From the control terminal, send the

 

 

 

 

CLR ALM command

 

REMOTE DB

The data base currently stored in the

1. Load the default configuration in

ON/OFF

CHECKSUM ERROR

non-volatile memory of the remote

 

the place of the current data base

 

 

ASMi-450 is corrupted. Message can

 

(from the control terminal, enter

 

 

appear only upon power-up

 

the INIT DB command)

 

 

 

2. Replace the ASMi-450

 

REMOTE DB-INIT

Section DB INI of switch S1 of the

If it is no longer necessary to enforce

ON

SWITCH IS ON

remote ASMi-450 is set to ON

the default data base parameter

 

 

 

values, change setting to OFF

 

REMOTE DTE NOT

No data is received from the remote

Check the remote LAN or DTE

ON/OFF

CONNECTED

user's port (for an ASMi-450 version

connection

 

 

with serial data port).

 

 

 

 

or

 

 

 

 

The remote Ethernet interface is not

 

 

 

 

connected to an operating LAN (at

 

 

 

 

least one station must be active on

 

 

 

 

the LAN)

 

 

 

REMOTE HARDWARE

Remote ASMi-450 technical failure

Replace the ASMi-450

ON/OFF

FAILURE

(failure of one of the internal

 

 

 

 

programmable components)

 

 

 

REMOTE LOW

The far-end block error rate (FEBE)

1. Check the HDSL line connecting

ON

QUALITY ALARM

reported via the HDSL line exceeds

 

the two ASMi-450 units.

 

 

10-7

2. Perform self-test on the two

 

 

 

 

ASMi-450 and replace the

 

 

 

 

ASMi-450 that fails the self-test

 

REMOTE PSWRD

Section PSWD of switch S1 of the

If it is no longer necessary to enforce

ON

SWITCH IS ON

remote ASMI-450 is set to ON

the default password and node

 

 

 

number, change setting to OFF

 

REMOTE REAL TIME

The battery that powers the remote

Have the ASMi-450 repaired

ON

CLOCK BATTERY

ASMi-450 internal real-time clock

 

 

 

FAILURE

when ASMi-450 is not powered has

 

 

 

 

failed

 

 

 

5-4

ASMi-450 Installation and Operation Manual

Image 92
Contents ASMi-450 Warranty Selv HdslRegulatory Information Declaration of Conformity Page Contents ASMi-450 Control from the Control Port Appendix a Connector Wiring Contents List of Figures List of Figures Xii List of Tables List of Tables Xiv Starting the Configuration Preliminary Preparations Starting ProcedureFunction Terminal Type TV920 VT52 VT100 Freedom 100/110 Configuration ProcedureStep Action Use the Command Command Index Type Configuration Display Commands Control CommandsQuick-Start Guide Purpose and Main Features Functional DescriptionTypical Application for ASMi-450 with Data Interface Hdsl Subsystem Characteristics System Timing Internal timingRemote Management Control ASMi-450 OperationLocal Control Introduction Test and Diagnostics Capabilities AlarmsPhysical Characteristics Power RequirementsOperating Environment Transmission Media Hdsl Line SignalBinary Digits Quaternary Symbol Hdsl Signal Structure HDSL-Related System Functions Technical Specifications Hdsl InterfaceEthernet Interface Physical Characteristics Chapter Installation GeneralUnpacking Site RequirementsOpening ASMi-450 Case ASMi-450 Configuration InformationGeneral Jumper and Switch Location Functions Switch S1ASMi-450 Internal Settings OFF Jumper FGND/GND Internal Settings Procedure Reinstalling ASMi-450 CoverJumper R/C Connector Location Grounding DC Power Connection Power Connection Users Port ConnectionsAC Power Connection Hdsl Line Connections Control Port Connection Chapter Front-Panel Operating Instructions ScopeFront Panel Controls, Connectors, and Indicators Control or Indicator FunctionEthernet Interface IndicatorsIndicator Function Control of ASMi-450 Operation, General General General Operating Instructions Display FunctionsConfiguration Parameters Status MessagesTest Functions Display Description SeeUsing Front-Panel OrganizationASMi-450 Display Push-buttonsFront-Panel Operating Instructions System Configuration Parameters Designation Function ValuesControl Port Configuration Parameters Turn-on Checking Current Operating Configuration Operating InstructionsScroll DisplayCursor Fault Indications Step Action Key DisplayNormal Front-Panel Indications Ethernet Interface IndicationsLocal Configuration Set-Up Procedure PasswordConfiguration Procedure ProtectionAlready there Scroll to display the desired group Specific Configuration Guidelines Alarm BufferSP Parameters LCD Configuration Error Messages Front-Panel Operating Instructions Chapter ASMi-450 Control from the Control Port Hardware Requirements Interface Type Data Terminal Ready DTRRequest to Send RTS Clear to Send CTSData Set Ready DSR Autobaud FunctionRing Indication RI Internal Settings Control Port ConfigurationPreparation for Use of Supervision Terminal ASMi-450 Preparations Supervision Terminal ConnectionsCommand Language Syntax Command Options Command ProtocolASMi-450 Supervision Language Option Meaning Example of UsageIndex of Commands Command Purpose Options ASMi-450 Command Set Description CLR ALMCLR Loop FormatDEF Agent CLR TSTDate DEF Name Display FieldsDEF Node DEF PWDDEF SP Purpose Format UsePWD DEF SYS DEF TermFormat Use DSP ALMFunction Terminal Type VT-52 VT-100 Freedom-110 Alarm No Alarm Syntax Meaning State Time Remote Alarm Remote Signal LossQuality Alarm Remote DBDSP HDR TST DSP ST LineREM LAN not ConnectedPurpose Format Use Display Format DSP ST PortDisplay Format DSP ST SYS ExitHelp Parameter Designation Default Value Init DBNode PasswordLoop Reset TimeStarting a Session Single ASMi-450 Control Session Ending a Control Session Configuration Error Messages ASMi-450 Control from the Control Port Indicators Display Status Indications and MessagesMessage Description Corrective Actions Alarm ON/OFFASMi-450 Alarm Buffer Messages Cont’d Remote Alarm Remote Reverse Test Functions Test FunctionsLoop REM REM Port Operating InstructionsPower-Up Self-Test Activating the Test Functions from a Control TerminalTroubleshooting Instructions Trouble Symptoms Probable Cause Corrective MeasuresLAN RS-530 DCE Connector and Adapter Cables Pin Designation Direction FunctionRceb Pin Designation Direction Function 36/RS-449/422Rcea V.35 DCE Connector X.21 DCE Connector Hdsl Line Connector RS-232 V.24 Control Port ConnectorPin Function Pin Line Connected Connected to To TerminalEthernet Interface Connector Appendix B Snmp Management Snmp Operations Snmp EnvironmentGeneral Snmp Principles MIBs Supported by the ASMi-450 Snmp Agent Management Information BaseMIB Structure Snmp Communities Access Restriction Using Snmp CommunitiesManagement Domains Under ASMi-450 Communities ReadIP Environment General IP EnvironmentIP Address Structure Address Class First Byte Address RangeSnmp Management Snmp Traps Appendix C Installation in 19 Racks Installation of Single Unit Figure C-1. Installation of Single Unit in 19 RackInstallation of Two Units General PreparationsFastening the Two Units To install the ferrite cores ASMi-450