RAD Data comm ASMI-450 operation manual DEF Name, Display Fields

Page 69

ASMi-450 Control from the Control Port

Display Fields

4. A typical display, as seen after all the parameters are selected, is shown below:

TELNET_APATHY_TIME

10 MIN

IP_ADDRESS XXX.XXX.XXX.XXX

READ

COMMUNITY

public

WRITE COMMUNITY

private

TRAP

COMMUNITY IS public

where X stands for the digits of the IP address.

The agent parameters displayed on the data form, and their range of values, are as follows:

TELNET_APATHY_TIME

Press the F or B keys to select the time, in minutes,

 

after which a Telnet connection will be automatically

 

terminated if no incoming activity is detected.

 

The available values are 10MIN, 15MIN, and 20MIN.

IP_ADDRESS

Type in the IP address assigned to the ASMi-450

 

SNMP agent in the dotted-quad format (four groups of

 

digits in the range of 0 through 255, separated by

 

periods).

READ COMMUNITY

Type in the name of the SNMP community that has

 

read-only authorization (the ASMi-450 SNMP agent

 

will accept only getRequest and

 

getNextRequest commands from management

 

stations using that community). You may enter up to

 

32 alphanumeric characters.

WRITE COMMUNITY

Type in the name of the SNMP community that has

 

read-write authorization (the ASMi-450 SNMP agent

 

will also accent setRequest commands from

 

management stations using that community). You may

 

enter up to 32 alphanumeric characters.

TRAP COMMUNITY

Type in the name of the SNMP community to which

 

the ASMi-450 SNMP agent will send traps. You may

 

enter up to 32 alphanumeric characters.

DEF NAME------------------------------------------------------------------------------------

Purpose

Define the node name (up to eight alphanumeric characters).

Format

DEF NAME

Use

1. To define the ASMi-450 node name, type:

 

DEF NAME<CR>

ASMi-450 Installation and Operation Manual

4-11

Image 69
Contents ASMi-450 Warranty Hdsl SelvRegulatory Information Declaration of Conformity Page Contents ASMi-450 Control from the Control Port Appendix a Connector Wiring Contents List of Figures List of Figures Xii List of Tables List of Tables Xiv Preliminary Preparations Starting Procedure Starting the ConfigurationConfiguration Procedure Step Action Use the CommandFunction Terminal Type TV920 VT52 VT100 Freedom 100/110 Type Configuration Display Commands Control Commands Command IndexQuick-Start Guide Functional Description Purpose and Main FeaturesTypical Application for ASMi-450 with Data Interface Hdsl Subsystem Characteristics Internal timing System TimingControl ASMi-450 Operation Local ControlRemote Management Introduction Alarms Test and Diagnostics CapabilitiesPhysical Characteristics Power RequirementsTransmission Media Hdsl Line Signal Binary Digits Quaternary SymbolOperating Environment Hdsl Signal Structure HDSL-Related System Functions Hdsl Interface Technical SpecificationsEthernet Interface Physical Characteristics General Chapter InstallationSite Requirements UnpackingASMi-450 Configuration Information GeneralOpening ASMi-450 Case Switch S1 Jumper and Switch Location FunctionsASMi-450 Internal Settings OFF Internal Settings Procedure Reinstalling ASMi-450 Cover Jumper R/CJumper FGND/GND Connector Location Grounding Power Connection Users Port Connections AC Power ConnectionDC Power Connection Hdsl Line Connections Control Port Connection Scope Chapter Front-Panel Operating InstructionsControl or Indicator Function Front Panel Controls, Connectors, and IndicatorsIndicators Indicator FunctionEthernet Interface General General Operating Instructions Display Functions Control of ASMi-450 Operation, GeneralStatus Messages Configuration ParametersTest Functions Display Description SeeOrganization Using Front-PanelASMi-450 Display Push-buttonsFront-Panel Operating Instructions Designation Function Values System Configuration ParametersControl Port Configuration Parameters Operating Instructions Turn-on Checking Current Operating ConfigurationDisplay CursorScroll Step Action Key Display Fault IndicationsNormal Front-Panel Indications Ethernet Interface IndicationsPassword Local Configuration Set-Up ProcedureConfiguration Procedure ProtectionAlready there Scroll to display the desired group Alarm Buffer Specific Configuration GuidelinesSP Parameters LCD Configuration Error Messages Front-Panel Operating Instructions Chapter ASMi-450 Control from the Control Port Hardware Requirements Data Terminal Ready DTR Interface TypeRequest to Send RTS Clear to Send CTSAutobaud Function Ring Indication RIData Set Ready DSR Control Port Configuration Internal SettingsPreparation for Use of Supervision Terminal ASMi-450 Preparations Supervision Terminal ConnectionsCommand Protocol Command Language Syntax Command OptionsASMi-450 Supervision Language Option Meaning Example of UsageIndex of Commands Command Purpose Options CLR ALM ASMi-450 Command Set DescriptionCLR Loop FormatCLR TST DateDEF Agent Display Fields DEF NameDEF PWD DEF NodePurpose Format Use DEF SPPWD DEF Term DEF SYSDSP ALM Function Terminal Type VT-52 VT-100 Freedom-110Format Use Alarm No Alarm Syntax Meaning State Time Remote Signal Loss Remote AlarmQuality Alarm Remote DBDSP ST Line DSP HDR TSTREM LAN not ConnectedDSP ST Port Display FormatPurpose Format Use Display Format Exit DSP ST SYSHelp Init DB Parameter Designation Default ValuePassword LoopNode Time ResetStarting a Session Single ASMi-450 Control Session Ending a Control Session Configuration Error Messages ASMi-450 Control from the Control Port Status Indications and Messages Indicators DisplayON/OFF Message Description Corrective Actions AlarmASMi-450 Alarm Buffer Messages Cont’d Remote Alarm Remote Reverse Test Functions Test FunctionsOperating Instructions Loop REM REM PortActivating the Test Functions from a Control Terminal Power-Up Self-TestTrouble Symptoms Probable Cause Corrective Measures Troubleshooting InstructionsLAN Pin Designation Direction Function RS-530 DCE Connector and Adapter CablesPin Designation Direction Function 36/RS-449/422 RceaRceb V.35 DCE Connector X.21 DCE Connector RS-232 V.24 Control Port Connector Hdsl Line ConnectorPin Function Pin Line Connected Connected to To TerminalEthernet Interface Connector Appendix B Snmp Management Snmp Environment General Snmp PrinciplesSnmp Operations Management Information Base MIB StructureMIBs Supported by the ASMi-450 Snmp Agent Access Restriction Using Snmp Communities Management Domains UnderSnmp Communities Read ASMi-450 CommunitiesGeneral IP Environment IP EnvironmentIP Address Structure Address Class First Byte Address RangeSnmp Management Snmp Traps Appendix C Installation in 19 Racks Figure C-1. Installation of Single Unit in 19 Rack Installation of Single UnitGeneral Preparations Installation of Two UnitsFastening the Two Units ASMi-450 To install the ferrite cores