Front-Panel Operating Instructions

Step

Action

Key

Display

 

 

 

 

 

 

 

1

Bring the cursor under the top row (if not

CURSOR

 

 

already there)

 

 

2

Scroll to display the desired group of

SCROLL

Second row shows the first parameter in the

 

parameters in the top row

 

selected group and its current value

 

NOTE

 

 

 

When the desired group of parameters

 

 

 

must be independently selected for each

 

 

 

link, the top row includes an additional

 

 

 

field (at the rightmost side of the top

 

 

 

row): this field is used to select the

 

 

 

desired link number. In this case, use the

 

 

 

CURSOR key to bring the cursor to the

 

 

 

rightmost field, then SCROLL to show

 

 

 

the desired link number.

 

 

3

When the second row has more than one

CURSOR

The second row shows the parameter name

 

field, bring the cursor under the left-hand

SCROLL

and its current value

 

field (parameter name) in the second row,

 

 

 

and then scroll to display the desired

 

 

 

parameter in the selected group

 

 

4

Bring the cursor under the right-hand field

CURSOR

 

 

(the parameter value) in the second row

 

 

5

Scroll to set the required value for the

SCROLL

The second row shows the available values

 

displayed parameter

 

 

6

When the desired parameter value is

ENTER

The cursor returns to the first field in the top

 

displayed, select the new parameter value

 

row. The second row displays shortly

 

NOTE

 

CONFIG ENTER, then returns to the normal

 

You must press ENTER after changing

 

display

 

parameters of a certain group, e.g.,

 

 

 

SYSTEM. If you change parameter

 

 

 

values, but return the cursor to the first

 

 

 

field and scroll to another group

 

 

 

without pressing ENTER, the changes

 

 

 

are discarded and you will see the

 

 

 

message CONFIG LOST.

 

 

7

Repeat steps 3 through 6 until values are

SCROLL

The second row shows the current selection

 

assigned to all the parameters in the group

 

 

8

Repeat steps 1 through 7 until values are

SCROLL

The second row shows the current selection

 

assigned to all the parameters in the desired

 

 

 

groups

 

 

3-14

ASMi-450 Installation and Operation Manual

Image 54
Contents ASMi-450 Warranty Selv HdslRegulatory Information Declaration of Conformity Page Contents ASMi-450 Control from the Control Port Appendix a Connector Wiring Contents List of Figures List of Figures Xii List of Tables List of Tables Xiv Starting the Configuration Preliminary Preparations Starting ProcedureConfiguration Procedure Step Action Use the CommandFunction Terminal Type TV920 VT52 VT100 Freedom 100/110 Command Index Type Configuration Display Commands Control CommandsQuick-Start Guide Purpose and Main Features Functional DescriptionTypical Application for ASMi-450 with Data Interface Hdsl Subsystem Characteristics System Timing Internal timingControl ASMi-450 Operation Local ControlRemote Management Introduction Physical Characteristics Test and Diagnostics CapabilitiesAlarms Power RequirementsTransmission Media Hdsl Line Signal Binary Digits Quaternary SymbolOperating Environment Hdsl Signal Structure HDSL-Related System Functions Technical Specifications Hdsl InterfaceEthernet Interface Physical Characteristics Chapter Installation GeneralUnpacking Site RequirementsASMi-450 Configuration Information GeneralOpening ASMi-450 Case Jumper and Switch Location Functions Switch S1ASMi-450 Internal Settings OFF Internal Settings Procedure Reinstalling ASMi-450 Cover Jumper R/CJumper FGND/GND Connector Location Grounding Power Connection Users Port Connections AC Power ConnectionDC Power Connection Hdsl Line Connections Control Port Connection Chapter Front-Panel Operating Instructions ScopeFront Panel Controls, Connectors, and Indicators Control or Indicator FunctionIndicators Indicator FunctionEthernet Interface Control of ASMi-450 Operation, General General General Operating Instructions Display FunctionsTest Functions Configuration ParametersStatus Messages Display Description SeeASMi-450 Display Using Front-PanelOrganization Push-buttonsFront-Panel Operating Instructions System Configuration Parameters Designation Function ValuesControl Port Configuration Parameters Turn-on Checking Current Operating Configuration Operating InstructionsDisplay CursorScroll Normal Front-Panel Indications Fault IndicationsStep Action Key Display Ethernet Interface IndicationsConfiguration Procedure Local Configuration Set-Up ProcedurePassword ProtectionAlready there Scroll to display the desired group Specific Configuration Guidelines Alarm BufferSP Parameters LCD Configuration Error Messages Front-Panel Operating Instructions Chapter ASMi-450 Control from the Control Port Hardware Requirements Request to Send RTS Interface TypeData Terminal Ready DTR Clear to Send CTSAutobaud Function Ring Indication RIData Set Ready DSR Preparation for Use of Supervision Terminal Internal SettingsControl Port Configuration ASMi-450 Preparations Supervision Terminal ConnectionsASMi-450 Supervision Language Command Language Syntax Command OptionsCommand Protocol Option Meaning Example of UsageIndex of Commands Command Purpose Options CLR Loop ASMi-450 Command Set DescriptionCLR ALM FormatCLR TST DateDEF Agent DEF Name Display FieldsDEF Node DEF PWDDEF SP Purpose Format UsePWD DEF SYS DEF TermDSP ALM Function Terminal Type VT-52 VT-100 Freedom-110Format Use Alarm No Alarm Syntax Meaning State Time Quality Alarm Remote AlarmRemote Signal Loss Remote DBREM LAN not DSP HDR TSTDSP ST Line ConnectedDSP ST Port Display FormatPurpose Format Use Display Format DSP ST SYS ExitHelp Parameter Designation Default Value Init DBPassword LoopNode Reset TimeStarting a Session Single ASMi-450 Control Session Ending a Control Session Configuration Error Messages ASMi-450 Control from the Control Port Indicators Display Status Indications and MessagesMessage Description Corrective Actions Alarm ON/OFFASMi-450 Alarm Buffer Messages Cont’d Remote Alarm Remote Reverse Test Functions Test FunctionsLoop REM REM Port Operating InstructionsPower-Up Self-Test Activating the Test Functions from a Control TerminalTroubleshooting Instructions Trouble Symptoms Probable Cause Corrective MeasuresLAN RS-530 DCE Connector and Adapter Cables Pin Designation Direction FunctionPin Designation Direction Function 36/RS-449/422 RceaRceb V.35 DCE Connector X.21 DCE Connector Pin Function Hdsl Line ConnectorRS-232 V.24 Control Port Connector Pin Line Connected Connected to To TerminalEthernet Interface Connector Appendix B Snmp Management Snmp Environment General Snmp PrinciplesSnmp Operations Management Information Base MIB StructureMIBs Supported by the ASMi-450 Snmp Agent Access Restriction Using Snmp Communities Management Domains UnderSnmp Communities ASMi-450 Communities ReadIP Address Structure IP EnvironmentGeneral IP Environment Address Class First Byte Address RangeSnmp Management Snmp Traps Appendix C Installation in 19 Racks Installation of Single Unit Figure C-1. Installation of Single Unit in 19 RackInstallation of Two Units General PreparationsFastening the Two Units To install the ferrite cores ASMi-450