Introduction

 

CENTRAL ASMi-450

REMOTE ASMi-450

 

 

~

Internal

 

 

 

 

Timing

HDSL

 

 

 

 

 

 

 

 

 

 

Line

 

 

Local

User

HDSL Line

HDSL Line

User

Remote

User's

User's

Interface

Interface

Interface

Interface

DTE

DTE

 

 

 

 

Timing

 

 

 

 

 

Source

 

 

 

 

 

Figure 1-D. Flow of Timing Signals through ASMi-450 System in the Internal Timing Mode

Control of

ASMi-450

Operation

ASMi-450 Unit Configured as Remote Unit (NTU). The ASMi-450 unit configured as remote unit always locks its internal system timing to the incoming HDSL signal, which is received from the ASMi-450 unit configured as central unit. The receive path of the ASMi-450 uses the recovered timing to generate the data stream supplied to the equipment connected to the remote user's port. Therefore, the receive path of the remote ASMi-450 transparently transfers the timing from the HDSL line to the remote user's equipment.

The ASMi-450 system is designed for unattended operation. The configuration of the ASMi-450, that is, a complete collection of operating parameters, is determined by a data base stored in non-volatile memory.

Local Control

The ASMi-450 can be controlled by means of a simple menu, operated by push- buttons located on the front panel. During set-up, an LCD display guides the operator in the execution of the desired operations. The display provides information concerning the current system configuration and operating mode, and the available values of each programmable parameter. In case of operator errors, the ASMi-450 displays a message that explains the error and helps the operator take the correct action.

Remote Management

In addition to front panel control, the ASMi-450 supports management from a remote location. The remote management capabilities can be used to perform the following activities:

ASMi-450 configuration.

Reading of ASMi-450 status.

ASMi-450 testing.

Display of alarm status and history.

ASMi-450 Installation and Operation Manual

1-5

Image 23
Contents ASMi-450 Warranty Hdsl SelvRegulatory Information Declaration of Conformity Page Contents ASMi-450 Control from the Control Port Appendix a Connector Wiring Contents List of Figures List of Figures Xii List of Tables List of Tables Xiv Preliminary Preparations Starting Procedure Starting the ConfigurationFunction Terminal Type TV920 VT52 VT100 Freedom 100/110 Configuration ProcedureStep Action Use the Command Type Configuration Display Commands Control Commands Command IndexQuick-Start Guide Functional Description Purpose and Main FeaturesTypical Application for ASMi-450 with Data Interface Hdsl Subsystem Characteristics Internal timing System TimingRemote Management Control ASMi-450 OperationLocal Control Introduction Power Requirements Test and Diagnostics CapabilitiesAlarms Physical CharacteristicsOperating Environment Transmission Media Hdsl Line SignalBinary Digits Quaternary Symbol Hdsl Signal Structure HDSL-Related System Functions Hdsl Interface Technical SpecificationsEthernet Interface Physical Characteristics General Chapter InstallationSite Requirements UnpackingOpening ASMi-450 Case ASMi-450 Configuration InformationGeneral Switch S1 Jumper and Switch Location FunctionsASMi-450 Internal Settings OFF Jumper FGND/GND Internal Settings Procedure Reinstalling ASMi-450 CoverJumper R/C Connector Location Grounding DC Power Connection Power Connection Users Port ConnectionsAC Power Connection Hdsl Line Connections Control Port Connection Scope Chapter Front-Panel Operating InstructionsControl or Indicator Function Front Panel Controls, Connectors, and IndicatorsEthernet Interface IndicatorsIndicator Function General General Operating Instructions Display Functions Control of ASMi-450 Operation, GeneralDisplay Description See Configuration ParametersStatus Messages Test FunctionsPush-buttons Using Front-PanelOrganization ASMi-450 DisplayFront-Panel Operating Instructions Designation Function Values System Configuration ParametersControl Port Configuration Parameters Operating Instructions Turn-on Checking Current Operating ConfigurationScroll DisplayCursor Ethernet Interface Indications Fault IndicationsStep Action Key Display Normal Front-Panel IndicationsProtection Local Configuration Set-Up ProcedurePassword Configuration ProcedureAlready there Scroll to display the desired group Alarm Buffer Specific Configuration GuidelinesSP Parameters LCD Configuration Error Messages Front-Panel Operating Instructions Chapter ASMi-450 Control from the Control Port Hardware Requirements Clear to Send CTS Interface TypeData Terminal Ready DTR Request to Send RTSData Set Ready DSR Autobaud FunctionRing Indication RI ASMi-450 Preparations Supervision Terminal Connections Internal SettingsControl Port Configuration Preparation for Use of Supervision TerminalOption Meaning Example of Usage Command Language Syntax Command OptionsCommand Protocol ASMi-450 Supervision LanguageIndex of Commands Command Purpose Options Format ASMi-450 Command Set DescriptionCLR ALM CLR LoopDEF Agent CLR TSTDate Display Fields DEF NameDEF PWD DEF NodePurpose Format Use DEF SPPWD DEF Term DEF SYSFormat Use DSP ALMFunction Terminal Type VT-52 VT-100 Freedom-110 Alarm No Alarm Syntax Meaning State Time Remote DB Remote AlarmRemote Signal Loss Quality AlarmConnected DSP HDR TSTDSP ST Line REM LAN notPurpose Format Use Display Format DSP ST PortDisplay Format Exit DSP ST SYSHelp Init DB Parameter Designation Default ValueNode PasswordLoop Time ResetStarting a Session Single ASMi-450 Control Session Ending a Control Session Configuration Error Messages ASMi-450 Control from the Control Port Status Indications and Messages Indicators DisplayON/OFF Message Description Corrective Actions AlarmASMi-450 Alarm Buffer Messages Cont’d Remote Alarm Remote Reverse Test Functions Test FunctionsOperating Instructions Loop REM REM PortActivating the Test Functions from a Control Terminal Power-Up Self-TestTrouble Symptoms Probable Cause Corrective Measures Troubleshooting InstructionsLAN Pin Designation Direction Function RS-530 DCE Connector and Adapter CablesRceb Pin Designation Direction Function 36/RS-449/422Rcea V.35 DCE Connector X.21 DCE Connector Pin Line Connected Connected to To Terminal Hdsl Line ConnectorRS-232 V.24 Control Port Connector Pin FunctionEthernet Interface Connector Appendix B Snmp Management Snmp Operations Snmp EnvironmentGeneral Snmp Principles MIBs Supported by the ASMi-450 Snmp Agent Management Information BaseMIB Structure Snmp Communities Access Restriction Using Snmp CommunitiesManagement Domains Under Read ASMi-450 CommunitiesAddress Class First Byte Address Range IP EnvironmentGeneral IP Environment IP Address StructureSnmp Management Snmp Traps Appendix C Installation in 19 Racks Figure C-1. Installation of Single Unit in 19 Rack Installation of Single UnitGeneral Preparations Installation of Two UnitsFastening the Two Units ASMi-450 To install the ferrite cores