MGE UPS Systems EX-7 manual Scope, Input voltage must be the same as output voltage on HV units

Page 15

Introduction

1.0Scope

Introduction is a general description of system configurations of the EX 5/7/11RT, and its mechanical electrical characteristics. Additionally there is an optional accessories section with important information on MGE products that will enhance the performance of the EX 5/7/11RT. Please contact your MGE representative for detailed information on these options.

Table 1-1: EX RT Model Descriptions and Contents.

System Description

 

 

 

 

System Contents

 

 

Output

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Module

 

Battery Module

Transformer

 

Model #

Part #

 

 

Module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

86215

 

86216

 

86217

86207

 

86209

86211

 

 

 

 

 

 

 

 

 

 

 

 

 

5 kVA

86050

X

 

 

 

 

X

 

 

 

200/208/220/

HV EX 5RT

 

 

 

 

 

 

 

230/240/250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 kVA

86201

X

 

 

 

 

X

 

 

X

120/208/240

LV EX 5RT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 kVA

86070

 

 

X

 

 

X

 

 

 

200/208/220/

HV EX 7RT

 

 

 

 

 

 

 

230/240/250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 kVA

86203

 

 

X

 

 

X

 

 

X

120/208/240

LV EX 7RT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11 kVA

86110

 

 

 

 

X

 

 

X

 

200/208/220/

HV EX 11RT

 

 

 

 

 

 

 

230/240/250

 

 

 

 

 

 

 

 

 

 

 

 

11 kVA

86205

 

 

 

 

X

 

 

X

X

120/208/240

LV EX 11RT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Also: All units include rail kits for rack mounting and stabilizing feet for tower configuration.

NOTE

The Power Module is factory configured for single Mains input at 208VAC,

 

60Hz. Other input-output voltage settings are available. See section 3.2.1.

 

Input voltage must be the same as output voltage on HV units!

 

 

Thank you for selecting an MGE UPS SYSTEMS, INC. (MGE) product to protect your electrical equipment.

The product you selected is a part of the EX RT series. The EX RT series is a family of Uninterruptible Power Supply (UPS) designed to provide safe, and reliable AC power backup for sensitive electrical equipment. To discover the entire range of MGE products, we invite you to visit our website at www.mgeups.com or contact your representa- tive at (800) 523-0142.

For a complete description of the EX RT product family and its available options, please refer to the following tables.

86-86000-00 B00

Introduction

1 — 1

Image 15
Contents EX 5/7/11RT Systems Page Technical Support Customer Care Center Hours 24/7 MGE UPS SYSTEMS, INC Scenic Avenue Costa Mesa, CA 92626 714EX 5/7/11RT Systems Contents Setup and Installation Return Policy for Repair of Single Phase Products RGA Technical Support and Product ServicesFigures Tables Certification Standards Important Safety InstructionsEnvironment Special PrecautionsAdditional Modules Serial Numbers Section Descriptions This page left blank intentionally Input voltage must be the same as output voltage on HV units ScopePart Number Description Transformer Module Characteristics Ratings System Electrical CharacteristicsTower Configuration Standard ConfigurationRack Configuration Model Dimensions HxWxD WeightsRear Panel Components Power Module EX 5/7/11 RTPower Module Display and Control Panel EX RT Transformer Module1 1 R T Optional Accessories Power Module Rail KitBattery/Transformer/CLA Module Rail Kit Battery Extension Cable Kit Multiple Battery Module Backup Time at Full LoadInput/Output Box Battery Integration Kit with CastersEX RT Transformer Module Contents CLA Module Contents EX 5/7/11RTRecommended Batteries All Modules are shipped in separate boxes Unpacking and Parts CheckContents of Standard EX 5/7/11RT Systems Contents of EXB 5/7/11RT Battery Module PN 86207 /86209 Installation in Tower Configuration Installation in Rack Mounting Configuration Not to scale Page Bracket System Install input/output cables Per .7 prior to this stepCommunication Ports Connecting the RS232 Communication PortInstallation of Optional Transverse Card Connecting the Dry Relay Contact Communication PortDual port Shut Card Dual U-Talk/Basic CardJBus Card Proper operationRemote Emergency Power Off Repo Communication Port System Connections Max AWG EX 11RTSources are open OFF/OPEN Output Always connect the earth ground wire firstConnecting EX RT Transformer Module Protection for all transformer output terminals120VAC output terminals Lb-N, La-N Bypass AC Mains Power Module I/O Box Connection of Battery Module EXB Connection of Optional CLA Module AC InputThis page left blank intentionally Required for initial startup only Initial StartupControl Panel with scroll up and down buttons UPS PersonalizationDisplay Factory setting Options Comments Display Factory setting OptionsMGE UPS SYSTEMS, INC Symptoms IT Network mode Industrial mode During the startup, if the Bypass AC source is out Then go to Advanced settings and UPS settingsUPS personalization through external software Final Startup sequenceOperating Modes Normal double conversion ModeECO mode display ECO ModeSecond Case Low battery warning Operation on Battery PowerTransfer to Battery Power First Case Operation on batteryPower to the load Return of Normal AC sourceShutdown Symptoms Indication Correction TroubleshootingBattery Fault LED 1CXXXXXXX Hot Swapping the Power ModuleRe-connecting the Power Module Hot Swapping the Battery Module Disconnecting the Battery ModuleRe-connecting the Battery Module This page left blank intentionally Source Voltage Frequency Electrical SpecificationsSystem Input/Output Power Ratings System Overload CharacteristicsSystem Backup Characteristics System Short Circuit ProtectionEX RT CLA Module KVA / kW 25% 50% 75% 100% Output load percentage Configuration for Hours backup timeSystem Environmental CharacteristicsOperation Mode On-line On Battery Heat RejectionProprietary Rights Statement MGE Standard Single Phrase WarrantyWarranty Extension Warranty+ not available on products User InformationProduct information Part Number Assembly Number Serial number Scheduling Field Service Engineer SupportEX 5/7/11RT Systems Glossary IEC Osha This page left blank intentionally Reorder Form Scenic Avenue Costa Mesa, CA Contact MGE