American Power Conversion PD80KL6FK1-M, PD80KG6FK1-M, PD80KF6FK1-M manual 30A, 3-wire power cables

Page 65

Customizing and Updating the PDU

Power Cables

30A, 3-wire power cables

 

 

 

 

 

 

 

PDW7L6-30C

7-foot power cable

PDW43L6-30C

43-foot power cable

PDW9L6-30C

9-foot power cable

PDW45L6-30C

45-foot power cable

PDW11L6-30C

11-foot power cable

PDW47L6-30C

47-foot power cable

PDW13L6-30C

13-foot power cable

PDW49L6-30C

49-foot power cable

PDW15L6-30C

15-foot power cable

PDW51L6-30C

51-foot power cable

PDW17L6-30C

17-foot power cable

PDW53L6-30C

53-foot power cable

PDW19L6-30C

19-foot power cable

PDW55L6-30C

55-foot power cable

PDW21L6-30C

21-foot power cable

PDW57L6-30C

57-foot power cable

PDW23L6-30C

23-foot power cable

PDW59L6-30C

59-foot power cable

PDW25L6-30C

25-foot power cable

PDW61L6-30C

61-foot power cable

PDW27L6-30C

27-foot power cable

PDW63L6-30C

63-foot power cable

PDW29L6-30C

29-foot power cable

PDW65L6-30C

65-foot power cable

PDW31L6-30C

31-foot power cable

PDW67L6-30C

67-foot power cable

PDW33L6-30C

33-foot power cable

PDW69L6-30C

69-foot power cable

PDW35L6-30C

35-foot power cable

PDW71L6-30C

71-foot power cable

PDW37L6-30C

37-foot power cable

PDW73L-30C

73-foot power cable

PDW39L6-30C

39-foot power cable

PDW75L6-30C

75-foot power cable

PDW41L6-30C

41-foot power cable

 

 

 

 

 

 

80kW InfraStruXure PDU—Operation and Configuration

57

Image 65
Contents 80kW InfraStruXure PDU Page About This Manual How to find updates to this manualAudience Companion manualsPage Contents System Operation Specifications Product Information Safety symbols used in this manual SafetyCross-reference symbols used in this manual OverviewMaintenance performed while the PDU is receiving input power Installation/MaintenanceEmergency Power Off EPO Total Power OffEMI InfraStruXure PDU Components OverviewPDU front view exterior Front view interior Front view door open  Wraparound Maintenance bypass Panel-Rear view interior PDU monitoring unit   User connection platePage        PDU Display InterfaceNavigating through screens Top-level status screensTop-level menu screen Password-protected screens Load-Meter Screen Power FactorVolt-Meter Screen Overview Contacts ScreenInput Contacts Open or ClosedPDU Display Interface How to connect contacts to the PDU monitoring unit Main Input Breakers ScreenBypass Input Cross TieNew Logged Items Alarms ScreenEntire Log Clear LogAlarm Beeper Alarm SetupLoading Limits Voltage LimitsAlarm Condition Explanation Message When Condition Cleared PDU AlarmsBranch Ckt Limits Panel ScreenBranch Ckt Loading Distribution panel Panel ConfigurationGlobal Panel Config System Password Config ScreenSystem/Network Date/TimeOutput Config Electrical ConfigInput Config Firmware Updates Factory DefaultsManufacturer Data System IDSystem Operation How to Transfer the UPS into Maintenance Bypass OperationSystem Operation System Operation How to Return from Maintenance Bypass Operation Confirm Yes, UPS Load on No, Abort Confirm Yes, UPS into Bypass No, Abort Set the UPS System Enable switch to the OFF position How to Ensure Total Power OffSystem Operation How to Apply Power to the System PowerView RM Rev 000 English Please wait Top-Level Status Screen System Operation InfraStruXure PDU Management Options Communication ConfigurationInfraStruXure Manager Network management interfacesConnect the InfraStruXure PDU to the InfraStruXure Manager Configuring the InfraStruXure ManagerConnect the InfraStruXure PDU to your network Configuring the Network Management InterfaceConfiguration Overview Device IP Configuration Wizard TCP/IP configuration methodsBootp & Dhcp configuration Option 43 = 01 04 31 41 50 43 where Remote access to the control console Local access to the control consoleUse apc for the User Name and Password Choose Network from the Control Console menu Use apc for both User Name and PasswordControl console Web interface Snmp FTP and SCP 80kW InfraStruXure PDU-Operation and Configuration Customizing and Updating the PDU Important Safety InstructionsCircuit Breakers Power CablesPDU Orderable Part List 30A, 3-wire power cables Add a circuit breaker on the PDU How to Add Circuit Breakers and Power CablesAdd a power cable to the PDU or RDP Customizing and Updating the PDU Testing the EPO wiring and switches How to Test the EPO SwitchSafety warnings Customizing and Updating the PDU ATS 0 ATS 1 ATS Atsen How to connect contacts to the PDU monitoring unit Upgrading the PDU monitor processor How to Download Firmware UpgradesDownloading firmware upgrades from a local computer Xmodem 80kW InfraStruXure PDU SpecificationsPD80F6FK1-M PD80G6FK1-M PD80L6FK1-M PD80F6FK1-M PD80G6FK1-M PD80L6FK1-M Page Product Information InfraStruXure Standard WarrantyProduct Information Life-Support Policy APC Three-Phase SystemsHow to contact APC How to Obtain ServiceChanges in This Manual AppendixGeneral Changes Changes by page numberPage Index 80kW InfraStruXure PDU-Operation and Configuration UPS Page Page Page Page APC Worldwide Customer Support