Runco SP-60, SP-42, SP-50 manual Typical Test Pattern for Adjusting Sharpness

Page 47

Operation

Like the brightness and contrast controls, the color and tint controls

Note are interactive. A change to one may require a subtle change to the other in order to achieve the optimum setting.

Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust sharpness, select Sharpness from the Picture menu and press SET. On your external test pattern source, select a pattern like the one shown in Figure 4-6.Adjust as needed, looking for white edges around the transitions from black to gray and different sized lines in the “sweep” patterns at the top and bottom. Lower the sharpness setting to eliminate them.

Figure 4-6. Typical Test Pattern for Adjusting Sharpness

White Balance (Installer Adjust mode): Select White Balance from the Installer Adjust/Picture menu to remove any trace of color from the white areas of the image.

Gain: Use the Gain controls to correct color imbalances in the bright areas of the image. A good way to do this is to use a test pattern consisting mostly of solid white areas, such as an 80 IRE “window” pattern. If the white areas contain traces of red, green or blue, decrease the Gain for that color.

Offset: Use the Offset controls in the White Balance sub-menu to correct color imbalances in the dark areas of the image. A good way to do this is to use a test pattern consisting mostly of dark gray areas, such as a 30 IRE “window” pattern. If the gray areas contain traces of red, green or blue, decrease the Offset for that color.

To reset the white balance settings to the factory default values, select White Bal. Reset. Then, press to highlight YES and press SET.

Select Return to exit the White Balance menu.

WHITE BALANCE

R. GAIN

:

+128

G. GAIN

:

+128

B. GAIN

:

+128

R. OFFSET

:

+128

G. OFFSET

:

+128

B. OFFSET

:

+128

WHITE BAL. RESET

 

 

RETURN

 

 

 

 

 

SET ENTER

MENU

EXIT

 

 

 

Runco CinemaWall SP-42/-50/-60 Owner’s Operating Manual

37

Image 47
Contents SP-42 SP-50 SP-60 Page For Plasma Displays Three Year Limited WarrantyRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Safety Precautions Table of Contents Serial Communications Maintenance and TroubleshootingSpecifications OperationList of Figures Page About This Manual IntroductionIf you need Turn to Using This ManualKey Features and Benefits Description, Features and BenefitsOptional Accessories CinemaWall at a Glance Controls and IndicatorsControls and Functions Display Stand SP-42, SP-50 and SP-60 respectively ConnectorsSP-50 Connector Panel Combination IN/OUT Main Power Switch CinemaWall Remote ControlSET Button Page Remote Control InstallationOther surfaces Step Procedure For Details, refer to Quick SetupMounting the CinemaWall InstallationConsiderations High-Altitude OperationVentilation Ambient LightInstallation Video Connections Connections to the CinemaWallAnalog RGB OUT Input 1 Connection Standby modeComposite or S-Video Input 3 Connection Computer/Video Signal Compatibility onComponent Video Input 4 Connection Attaching the Small Ferrite Cores to Audio Cables Audio Connections11. Audio Output Connection Connection RS-232 ControllerPage Changing the OSD Language Turning on the PowerOperation Setting the Computer Display Properties Selecting an Input Source Viewing Input Signal InformationChanging the Aspect Ratio Aspect Ratio Description Aspect Ratio SettingsPIX by PIX Trained service personnel only Using the On-Screen MenusInstaller Adjust menu is intended for use by authorized CinemaWall OSD Menu Structure Picture Main MenuTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness Screen OFF PowerSet-Up DVI Setup Option Language Refer to Changing the OSD Language onUnder some conditions such as when the input signal consists Installer ADJ Input Option Installer Adjust ModeFAN Speed Auto ISF CCC color mode is pre-set to approximately 3,200K This action is not undoable. Proceed with caution Seamless Switch is not available when using PIPTo use PIP, press the Split button Using Picture-In-Picture PIPPIP Windows Swapping the MainViewing an Enlarged Area of the Display Enlarging One Part of the ScreenPage Cleaning the Display Panel Body and Remote Control Maintenance and TroubleshootingCleaning Troubleshooting TipsFAN Failure OUT of Range Signal NGThermal Alert Shut DownExample RS-232 Connection and Port ConfigurationSerial Command Syntax Serial CommunicationsAspect Ratio Command Value Range DescriptionMinimum Maximum Input Select NotePicture-in-Picture PIP VideoAudio MSTS10 MSTS08MSTS09 On left SET-UP Menu CommandsSets 2-screen operation to 2 Screen Side-by-side, full height main screenHigh LOWAuto Option Menu CommandsAverage Picture Menu Commands Installer Adjust Mode Option Menu Commands Installer Adjust Mode Screen Menu Commands Installer Adjust ModeSET-UP Menu Commands Installer Adjust Mode FMKS04 FMKS00FMKS02 FMKS034F 53 44 53 30 Sets OSD Display to OFF UPF Minimum Maximum Adjustment CommandsDW1 DWFCinemaWall Specifications SpecificationsDate of delivery to the end user Specifications are subject to change without noticeCinemaWall DimensionsCinemaWall Model SP-50 Dimensions with Optional Table Stand CinemaWall Model SP-60 Dimensions with Optional Table Stand Horiz Computer/Video Signal CompatibilityInput Refresh Rate Resolution Remarks56.0 45.1 Page Page Runco CL-810 Owner’s Operating Manual