Runco SP-60, SP-42, SP-50 manual Option Installer Adjust Mode, Installer ADJ Input

Page 53

Operation

Auto Function: The CinemaWall can automatically switch to Input 1 or Input 4 (Model SP-50/SP-60 only) when an image signal is detected at that input. To enable this feature, select Auto Function from the Option menu and set it to INPUT 1 (or INPUT 4, on a Model SP-50/SP-60).

After Auto Function triggers an input switch, when the Input 1 or Input 4 signal is no longer present, the input source reverts to the previously-selected input.

On the Model SP-42, Auto Function is supported on Input 1 only.

Note The input signal must be RGB with composite or separate sync; Auto Function will not work with sync-on-green RGB or component signals.

When Auto Function is active, selecting an input manually causes

Auto Function to be temporarily disabled. If you cycle power to the

CinemaWall, Auto Function becomes active again.

Program Timer (SP-42) / Screen Maint. (SP-50/SP-60):When in Installer Adjust mode, select Program Timer (SP-42) / Screen Maint. (SP-50/SP-60)from the Option menu to program the screen maintenance features of the CinemaWall to operate at regular intervals. This is useful for preventing image burn-in.

You can program the CinemaWall to switch inputs and/or replace the normal source signal with a white field, an inverse image or an “orbiting” image. You can specify a time of day and day of the week when you want this to take place.

To set up a screen maintenance program:

1.Press SET to select the DATE field for the first program. Press or to select one of the following:

SUN, MON, TUE, WED, THU, FRI or SAT for a program that runs once only on the next occurrence of that day.

* for a program that runs daily.

*SUN, *MON, *TUE, *WED, *THU, *FRI or *SAT for a program that runs weekly on that day.

2.Press SET, then followed by SET again to set the program start time.

3.Press or to set the hour component of the start time.

4.Press , then or to set the minute component of the start time.

5.Press SET, then followed by SET again to set the program end time (repeat steps 3 and 4).

6.Press SET, then followed by SET again to specify an input associated with this program. Choose “–” to specify the input that was active when the CinemaWall was last powered off.

7.Press SET, then followed by SET again to select the PATTERN field for this program. Press or to select one of the following:

Choose “–” to specify the function that was active when the CinemaWall was last powered off.

Choose WHITE to display a white field.

Choose INVERSE to display an inverse image.

Choose ORBITER to display an “orbiting” image.

Option (Installer Adjust Mode)

INSTALLER ADJ.

 

 

 

INPUT 3

PICTURE

SCREEN

SET-UP

OPTION

 

 

PROGRAM TIMER

 

 

 

 

 

TEST PATTERN

: OFF

 

 

 

SIDEBAR ADJ.

 

 

 

 

 

 

BAUD RATE

 

: 9600BPS

 

 

ID NUMBER

 

: ALL

 

SET

ENTER

 

 

MENU

EXIT

PROGRAM TIMER

DATE

ON

OFF

INPUT

PATTERN

*

10:00

–:–

*

20:00

–:–

WHITE

*

–:–

21:00

–:–

–:–

–:–

–:–

–:–

–:–

–:–

–:–

RETURN

 

 

 

SET

ENTER

 

 

MENU EXIT

Runco CinemaWall SP-42/-50/-60 Owner’s Operating Manual

43

Image 53
Contents SP-42 SP-50 SP-60 Page For Plasma Displays Three Year Limited WarrantyRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Safety Precautions Table of Contents Specifications Maintenance and TroubleshootingOperation Serial CommunicationsList of Figures Page About This Manual IntroductionIf you need Turn to Using This ManualKey Features and Benefits Description, Features and BenefitsOptional Accessories CinemaWall at a Glance Controls and IndicatorsControls and Functions Display Stand SP-42, SP-50 and SP-60 respectively ConnectorsSP-50 Connector Panel Combination IN/OUT Main Power Switch CinemaWall Remote ControlSET Button Page Remote Control InstallationOther surfaces Step Procedure For Details, refer to Quick SetupConsiderations InstallationHigh-Altitude Operation Mounting the CinemaWallVentilation Ambient LightInstallation Video Connections Connections to the CinemaWallAnalog RGB OUT Input 1 Connection Standby modeComposite or S-Video Input 3 Connection Computer/Video Signal Compatibility onComponent Video Input 4 Connection Attaching the Small Ferrite Cores to Audio Cables Audio Connections11. Audio Output Connection Connection RS-232 ControllerPage Changing the OSD Language Turning on the PowerOperation Setting the Computer Display Properties Selecting an Input Source Viewing Input Signal InformationChanging the Aspect Ratio Aspect Ratio Description Aspect Ratio SettingsPIX by PIX Trained service personnel only Using the On-Screen MenusInstaller Adjust menu is intended for use by authorized CinemaWall OSD Menu Structure Picture Main MenuTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness Screen OFF PowerSet-Up DVI Setup Option Language Refer to Changing the OSD Language onUnder some conditions such as when the input signal consists Installer ADJ Input Option Installer Adjust ModeFAN Speed Auto ISF CCC color mode is pre-set to approximately 3,200K This action is not undoable. Proceed with caution Seamless Switch is not available when using PIPTo use PIP, press the Split button Using Picture-In-Picture PIPPIP Windows Swapping the MainViewing an Enlarged Area of the Display Enlarging One Part of the ScreenPage Cleaning Maintenance and TroubleshootingTroubleshooting Tips Cleaning the Display Panel Body and Remote ControlThermal Alert OUT of Range Signal NGShut Down FAN FailureSerial Command Syntax RS-232 Connection and Port ConfigurationSerial Communications ExampleMinimum Maximum Command Value Range DescriptionInput Select Note Aspect RatioPicture-in-Picture PIP VideoAudio MSTS10 MSTS08MSTS09 Sets 2-screen operation to 2 Screen SET-UP Menu CommandsSide-by-side, full height main screen On leftHigh LOWAuto Option Menu CommandsAverage Picture Menu Commands Installer Adjust Mode Option Menu Commands Installer Adjust Mode Screen Menu Commands Installer Adjust ModeSET-UP Menu Commands Installer Adjust Mode FMKS02 FMKS00FMKS03 FMKS044F 53 44 53 30 Sets OSD Display to OFF DW1 Minimum Maximum Adjustment CommandsDWF UPFCinemaWall Specifications SpecificationsDate of delivery to the end user Specifications are subject to change without noticeCinemaWall DimensionsCinemaWall Model SP-50 Dimensions with Optional Table Stand CinemaWall Model SP-60 Dimensions with Optional Table Stand Input Refresh Rate Resolution Computer/Video Signal CompatibilityRemarks Horiz56.0 45.1 Page Page Runco CL-810 Owner’s Operating Manual