Runco SP-60, SP-42 Installation, Considerations, High-Altitude Operation, Mounting the CinemaWall

Page 26

Installation

3.3

Proper installation of your CinemaWall will ensure the highest possible picture quality.

Installation

Whether you are installing the CinemaWall temporarily or permanently, you should take

Considerations

the following into account to ensure that it performs optimally.

 

 

High-Altitude Operation

Due to the design of all plasma glass panels made by every manufacturer, and the

 

interaction between ambient air pressure and the plasma gases contained inside of the

 

panel, reliable operation of your plasma display cannot be assured during operation at

 

certain high-altitude locations.

 

Runco has found this plasma monitor to operate reliably at altitudes of up to 6000 MSL

 

(mean sea level). At elevations higher than this, each panel may react differently,

 

depending upon the altitude, air pressure, humidity and other meteorological factors.

 

For this reason, Runco International makes no warranties or claims as to the reliable

 

operation of the CinemaWall at altitudes greater than 6000 feet above sea level. If you are

 

planning to use this product at a location above 6000 feet, please contact Runco

 

technical support for further information.

Mounting the CinemaWall

To install the CinemaWall, you will need either an optional table stand or wall-mounting kit.

on a Wall or Table Stand

The CinemaWall cannot be installed on its own.

 

If you do decide to wall-mount the CinemaWall, ensure that the wall-mount bracket is

 

installed according to the instructions included with it. The wall must be capable of

 

supporting a redundant weight factor three (3) times the weight of the display, or be

 

reinforced.

 

 

Runco recommends that this be done by a custom installation specialist.

 

Note

Use only a Runco-approved wall-mount kit or table stand that is

 

specifically designed for your display.

You can attach your optional mounts or stand to the CinemaWall in either of two ways:

• While it is upright.

16 Runco CinemaWall SP-42/-50/-60 Owner’s Operating Manual

Image 26
Contents SP-42 SP-50 SP-60 Page Three Year Limited Warranty For Plasma DisplaysRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Safety Precautions Table of Contents Operation Maintenance and TroubleshootingSpecifications Serial CommunicationsList of Figures Page Introduction About This ManualUsing This Manual If you need Turn toDescription, Features and Benefits Key Features and BenefitsOptional Accessories CinemaWall at a Glance Controls and IndicatorsControls and Functions Display Stand Connectors SP-42, SP-50 and SP-60 respectivelySP-50 Connector Panel Combination IN/OUT CinemaWall Remote Control Main Power SwitchSET Button Page Installation Remote ControlOther surfaces Quick Setup Step Procedure For Details, refer toHigh-Altitude Operation InstallationConsiderations Mounting the CinemaWallAmbient Light VentilationInstallation Connections to the CinemaWall Video ConnectionsStandby mode Analog RGB OUT Input 1 ConnectionComputer/Video Signal Compatibility on Composite or S-Video Input 3 ConnectionComponent Video Input 4 Connection Audio Connections Attaching the Small Ferrite Cores to Audio Cables11. Audio Output Connection RS-232 Controller ConnectionPage Changing the OSD Language Turning on the PowerOperation Selecting an Input Source Viewing Input Signal Information Setting the Computer Display PropertiesChanging the Aspect Ratio Aspect Ratio Settings Aspect Ratio DescriptionPIX by PIX Trained service personnel only Using the On-Screen MenusInstaller Adjust menu is intended for use by authorized CinemaWall OSD Menu Structure Main Menu PictureTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness Screen OFF PowerSet-Up DVI Setup Language Refer to Changing the OSD Language on OptionUnder some conditions such as when the input signal consists Option Installer Adjust Mode Installer ADJ InputFAN Speed Auto ISF CCC color mode is pre-set to approximately 3,200K Seamless Switch is not available when using PIP This action is not undoable. Proceed with cautionUsing Picture-In-Picture PIP To use PIP, press the Split buttonSwapping the Main PIP WindowsEnlarging One Part of the Screen Viewing an Enlarged Area of the DisplayPage Troubleshooting Tips Maintenance and TroubleshootingCleaning Cleaning the Display Panel Body and Remote ControlShut Down OUT of Range Signal NGThermal Alert FAN FailureSerial Communications RS-232 Connection and Port ConfigurationSerial Command Syntax ExampleInput Select Note Command Value Range DescriptionMinimum Maximum Aspect RatioPicture-in-Picture PIP VideoAudio MSTS10 MSTS08MSTS09 Side-by-side, full height main screen SET-UP Menu CommandsSets 2-screen operation to 2 Screen On leftLOW HighAuto Option Menu CommandsAverage Picture Menu Commands Installer Adjust Mode Option Menu Commands Installer Adjust Mode Screen Menu Commands Installer Adjust ModeSET-UP Menu Commands Installer Adjust Mode FMKS03 FMKS00FMKS02 FMKS044F 53 44 53 30 Sets OSD Display to OFF DWF Minimum Maximum Adjustment CommandsDW1 UPFSpecifications CinemaWall SpecificationsSpecifications are subject to change without notice Date of delivery to the end userDimensions CinemaWallCinemaWall Model SP-50 Dimensions with Optional Table Stand CinemaWall Model SP-60 Dimensions with Optional Table Stand Remarks Computer/Video Signal CompatibilityInput Refresh Rate Resolution Horiz56.0 45.1 Page Page Runco CL-810 Owner’s Operating Manual