Runco SP-42, SP-50, SP-60 manual CinemaWall Specifications

Page 75

7. Specifications

Table 7-1lists the CinemaWall specifications.

Table 7-1. CinemaWall Specifications

Native Resolution:

Model SP-42: 1024 x 768

 

Model SP-50: 1365 x 768

 

Model SP-60: 1365 x 768

 

 

Screen Size (diagonal):

Model SP-42: 42 in.

 

Model SP-50: 50 in.

 

Model SP-60: 60 in.

 

 

Active Screen Area:

Model SP-42:36.28 x 20.29 in. (921.6 x 515.3 mm)

 

Model SP-50:43.45 x 24.50 in. (1103.6 x 622.3 mm)

 

Model SP-60:51.93 x 29.21 in. (1319.0 x 741.9 mm)

 

 

Screen Aspect Ratio:

16:9

 

 

Available Aspect Ratios:

Standard 4:3, Letterbox, 16:9 Anamorphic, VirtualWide™,

 

Virtual Cinema™, 14:9, Pix-by-Pix (no re-sizing)

 

 

DTV Compatibility:

480i/p, 525i/p, 540p, 625i/p, 720p, 1035i, 1080i; 50/60 Hz

 

 

ISF Settings:

Yes

 

 

Data/Graphics Compatibility:

Refer to Table 7-2

 

 

 

Inputs:

(1)

RGB/Component (15-pin D-sub); compatible with

 

Microsoft “Plug & Play” (VESA DDC 1/2B)

 

(1)

DVI with HDCP; compatible with Microsoft “Plug & Play”

 

(VESA DDC 2B)

 

(1)

Composite Video or S-Video (switch-selectable)

 

(1)

HD Component

 

(1)

DVI Video with HDCP

 

(5)

Audio (stereo mini-jack); 500 mV RMS / > 10 kΩ

 

(1)

RS-232 (9-pin D-sub female)

 

 

 

Outputs:

(1)

RGB (15-pin D-sub)

 

(1)

Speaker Terminals (stereo pair)

 

(1)

Audio (stereo mini-jack); 500 mV RMS / < 5 kΩ

 

 

Audio System:

Internal amplifier

 

Output Power =

 

8W RMS x 2 at 6Ω (Model SP-42)

 

9W RMS x 2 at 6Ω (Models SP-50 and SP-60)

 

 

Power Requirements:

100 to 240 VAC, 50/60Hz

 

 

Power Consumption:

Model SP-42:360 watts (1.5 watts in standby), maximum

 

Model SP-50:375 watts (1.5 watts in standby), maximum

 

Model SP-60: TBD

 

 

Operating Environment:

40ºF to 95ºF (5ºC to 35ºC);

 

20% to 80% humidity (non-condensing)

 

Altitude = up to 6,000 feet (1,828m)

 

 

 

7.1 CinemaWall Specifications

Runco CinemaWall SP-42/-50/-60 Owner’s Operating Manual

65

Image 75
Contents SP-42 SP-50 SP-60 Page For Plasma Displays Three Year Limited WarrantyRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Safety Precautions Table of Contents Serial Communications Maintenance and TroubleshootingSpecifications OperationList of Figures Page About This Manual IntroductionIf you need Turn to Using This ManualKey Features and Benefits Description, Features and BenefitsOptional Accessories Controls and Indicators Controls and FunctionsCinemaWall at a Glance Display Stand SP-42, SP-50 and SP-60 respectively ConnectorsSP-50 Connector Panel Combination IN/OUT Main Power Switch CinemaWall Remote ControlSET Button Page Remote Control InstallationOther surfaces Step Procedure For Details, refer to Quick SetupMounting the CinemaWall InstallationConsiderations High-Altitude OperationVentilation Ambient LightInstallation Video Connections Connections to the CinemaWallAnalog RGB OUT Input 1 Connection Standby modeComposite or S-Video Input 3 Connection Computer/Video Signal Compatibility onComponent Video Input 4 Connection Attaching the Small Ferrite Cores to Audio Cables Audio Connections11. Audio Output Connection Connection RS-232 ControllerPage Turning on the Power OperationChanging the OSD Language Setting the Computer Display Properties Selecting an Input Source Viewing Input Signal InformationChanging the Aspect Ratio Aspect Ratio Description Aspect Ratio SettingsPIX by PIX Using the On-Screen Menus Installer Adjust menu is intended for use by authorizedTrained service personnel only CinemaWall OSD Menu Structure Picture Main MenuTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness Screen Power Set-UpOFF DVI Setup Option Language Refer to Changing the OSD Language onUnder some conditions such as when the input signal consists Installer ADJ Input Option Installer Adjust ModeFAN Speed Auto ISF CCC color mode is pre-set to approximately 3,200K This action is not undoable. Proceed with caution Seamless Switch is not available when using PIPTo use PIP, press the Split button Using Picture-In-Picture PIPPIP Windows Swapping the MainViewing an Enlarged Area of the Display Enlarging One Part of the ScreenPage Cleaning the Display Panel Body and Remote Control Maintenance and TroubleshootingCleaning Troubleshooting TipsFAN Failure OUT of Range Signal NGThermal Alert Shut DownExample RS-232 Connection and Port ConfigurationSerial Command Syntax Serial CommunicationsAspect Ratio Command Value Range DescriptionMinimum Maximum Input Select NoteVideo AudioPicture-in-Picture PIP MSTS08 MSTS09MSTS10 On left SET-UP Menu CommandsSets 2-screen operation to 2 Screen Side-by-side, full height main screenHigh LOWOption Menu Commands AverageAuto Picture Menu Commands Installer Adjust Mode Screen Menu Commands Installer Adjust Mode SET-UP Menu Commands Installer Adjust ModeOption Menu Commands Installer Adjust Mode FMKS04 FMKS00FMKS02 FMKS034F 53 44 53 30 Sets OSD Display to OFF UPF Minimum Maximum Adjustment CommandsDW1 DWFCinemaWall Specifications SpecificationsDate of delivery to the end user Specifications are subject to change without noticeCinemaWall DimensionsCinemaWall Model SP-50 Dimensions with Optional Table Stand CinemaWall Model SP-60 Dimensions with Optional Table Stand Horiz Computer/Video Signal CompatibilityInput Refresh Rate Resolution Remarks56.0 45.1 Page Page Runco CL-810 Owner’s Operating Manual