Runco SP-42, SP-50, SP-60 manual Language Refer to Changing the OSD Language on, Option

Page 51

Operation

Sub Volume (Installer Adjust mode): Select Sub Volume from the Set-Up menu to adjust the audio input level for the current source. Do this for all sources, as needed to prevent sudden, drastic changes in sound volume when switching inputs.

For example, if a DVD player is connected to Input 4, a computer is connected to Input 1 and the audio output of the DVD player is fixed at a much higher level than that of the computer, reduce the Sub Volume for Input 4.

The Sub Volume control affects the current input only; the front-panel and remote volume controls are “master” controls; see Figure 4-7.

1

AUDIO INPUT

INPUT1

 

 

 

(INPUT1)

 

 

 

SUB VOLUME

 

 

 

 

 

 

2

AUDIO INPUT

INPUT2

INPUT

POWER

 

(INPUT2)

SUB VOLUME

SELECTOR

AMPLIFIER

3

AUDIO INPUT

INPUT3

 

 

SUB VOLUME

 

 

 

(INPUT3)

 

 

 

 

 

 

 

 

 

 

VOLUME

4

AUDIO INPUT

INPUT4

 

 

 

(INPUT4)

SUB VOLUME

 

 

5

AUDIO INPUT

INPUT5

 

 

 

(INPUT5)

SUB VOLUME

 

 

Figure 4-7. Audio System Functional Block Diagram

Language: Refer to Changing the OSD Language on page 27.

Energy Mode: Select Energy Mode from the Option menu to reduce power consumption and panel deterioration by limiting brightness of the screen. You can choose to limit brightness according to the input signal or in response to the ambient light level.

Select AVERAGE to limit brightness in accordance with the input signal to produce a bright, easily viewed image.

Select LEVEL 1 to limit brightness in accordance with the input signal. Power consumption is less than that used in AVERAGE mode.

Select LEVEL 2 to limit brightness in accordance with the input signal. Power consumption is less than that used in LEVEL1 mode.

Select LEVEL 3 to set the brightness at fixed level, regardless of input signal level (useful for preventing screen aging due to image burn).

Select AUTO (Model SP-42), AUTO1 or AUTO2 (Model SP-50/SP-60) to have the CinemaWall adjust the brightness automatically in response to ambient lighting conditions, to optimize picture quality.

To disable the Energy Mode feature, select MUTE (Model SP-50 and SP-60 only).

Option

CINEMAWALL

 

 

 

INPUT 3

PICTURE

SCREEN

SET-UP

OPTION

 

 

LANGUAGE

 

: ENGLISH

 

 

ENERGY MODE

: AUTO

 

 

 

TIME / DATE

 

 

 

 

 

 

PDP MGMT.

 

 

 

 

 

 

AUTO SETUP MODE

: OFF

 

 

 

AUTO FUNCTION

: OFF

 

SET

ENTER

 

 

MENU

EXIT

Runco CinemaWall SP-42/-50/-60 Owner’s Operating Manual

41

Image 51
Contents SP-42 SP-50 SP-60 Page For Plasma Displays Three Year Limited WarrantyRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Safety Precautions Table of Contents Serial Communications Maintenance and TroubleshootingSpecifications OperationList of Figures Page About This Manual IntroductionIf you need Turn to Using This ManualKey Features and Benefits Description, Features and BenefitsOptional Accessories Controls and Indicators Controls and FunctionsCinemaWall at a Glance Display Stand SP-42, SP-50 and SP-60 respectively ConnectorsSP-50 Connector Panel Combination IN/OUT Main Power Switch CinemaWall Remote ControlSET Button Page Remote Control InstallationOther surfaces Step Procedure For Details, refer to Quick SetupMounting the CinemaWall InstallationConsiderations High-Altitude OperationVentilation Ambient LightInstallation Video Connections Connections to the CinemaWallAnalog RGB OUT Input 1 Connection Standby modeComposite or S-Video Input 3 Connection Computer/Video Signal Compatibility onComponent Video Input 4 Connection Attaching the Small Ferrite Cores to Audio Cables Audio Connections11. Audio Output Connection Connection RS-232 ControllerPage Turning on the Power OperationChanging the OSD Language Setting the Computer Display Properties Selecting an Input Source Viewing Input Signal InformationChanging the Aspect Ratio Aspect Ratio Description Aspect Ratio SettingsPIX by PIX Using the On-Screen Menus Installer Adjust menu is intended for use by authorizedTrained service personnel only CinemaWall OSD Menu Structure Picture Main MenuTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness Screen Power Set-UpOFF DVI Setup Option Language Refer to Changing the OSD Language onUnder some conditions such as when the input signal consists Installer ADJ Input Option Installer Adjust ModeFAN Speed Auto ISF CCC color mode is pre-set to approximately 3,200K This action is not undoable. Proceed with caution Seamless Switch is not available when using PIPTo use PIP, press the Split button Using Picture-In-Picture PIPPIP Windows Swapping the MainViewing an Enlarged Area of the Display Enlarging One Part of the ScreenPage Cleaning the Display Panel Body and Remote Control Maintenance and TroubleshootingCleaning Troubleshooting TipsFAN Failure OUT of Range Signal NGThermal Alert Shut DownExample RS-232 Connection and Port ConfigurationSerial Command Syntax Serial CommunicationsAspect Ratio Command Value Range DescriptionMinimum Maximum Input Select NoteVideo AudioPicture-in-Picture PIP MSTS08 MSTS09MSTS10 On left SET-UP Menu CommandsSets 2-screen operation to 2 Screen Side-by-side, full height main screenHigh LOWOption Menu Commands AverageAuto Picture Menu Commands Installer Adjust Mode Screen Menu Commands Installer Adjust Mode SET-UP Menu Commands Installer Adjust ModeOption Menu Commands Installer Adjust Mode FMKS04 FMKS00FMKS02 FMKS034F 53 44 53 30 Sets OSD Display to OFF UPF Minimum Maximum Adjustment CommandsDW1 DWFCinemaWall Specifications SpecificationsDate of delivery to the end user Specifications are subject to change without noticeCinemaWall DimensionsCinemaWall Model SP-50 Dimensions with Optional Table Stand CinemaWall Model SP-60 Dimensions with Optional Table Stand Horiz Computer/Video Signal CompatibilityInput Refresh Rate Resolution Remarks56.0 45.1 Page Page Runco CL-810 Owner’s Operating Manual