CONNECTIONS
Check the DIP switch settings before connecting this controller. They need to be changed only if you want to change the sys- tem settings.
The following setting procedure should be made by qualified service personnel or system installers.
■DIP Switch Setting
Caution: Unplug the AC cord before changing any DIP switch setting.
●Removing the Bottom Cover for SW1
1. Take off the bottom cover by removing the two screws.
Remove two screws.
Bottom Cover
SW1
Panasonic
●Removing the Bottom Panel for SW100
1.Take off the side panels by removing the four screws.
2.Take off the bottom panel by removing the 8 screws.
●SW1
SW1 lets you choose 0/5V or open collector (O.C.) for the alarm recover output signal.
0/5V: +5 V DC approx. 500 m sec.
Open Collector (O.C.): 16 V DC 100 mA max. The initial factory setting is 0/5V.
SW1
O.C0/5V
●SW4
Confirm that SW4 on the board is set as shown below. This switch is used only for factory tests. Do not change this switch setting.
Bit 1 2 3 4
ON
OFF
SW4
w Remove four screws.
SW100
q
Remove four screws.
●SW100
SW100 lets you choose the mode for displaying charac- ters on the monitor.
SW100
NORREV
NOR: White with Black border
REV: Black with White border
The initial factory setting is NOR.
10